HVAC Layout & Specifications

The document provides specifications for various grille and linear diffusers required for an HVAC system. It lists the quantity, air flow, type, direction, length and other details of each component. Acoustic requirements in terms of Noise Criteria (NC) levels are also specified.

Uploaded by

seyedabubacker63
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
55 views6 pages

HVAC Layout & Specifications

The document provides specifications for various grille and linear diffusers required for an HVAC system. It lists the quantity, air flow, type, direction, length and other details of each component. Acoustic requirements in terms of Noise Criteria (NC) levels are also specified.

Uploaded by

seyedabubacker63
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd

SCH

S/L LOCATION/AREA

GUEST ENSUITE-01

GF-FCU-01
DRESSING ROOM

GUEST BEDROOM-01

GUEST ENSUITE-02

GF-FCU-02
DRESSING ROOM

GUEST BEDROOM-02

ABLUTION

GF-FCU-03 ABLUTION

PRAYER ROOM

POWDER ROOM

GF-FCU-04 MEP STORE

FAMILY LIVING & DINNING

LOBBY
GF-FCU-05
GUEST LOUNGE
STAIR CASE

LOBBY

GF-FCU-06 MAIN ENTRY LOBBY

MEP AREA
POWDER ROOM

GF-FCU-08
LOBBY

OFFICE
GF-FCU-09 MASLIS

GF-FCU-10 BUTLER KITCHEN

FOMAL LIVING
GF-FCU-12
FOMAL LIVING

GF-FCU-13 FOMAL LOUNGE


GF-FCU-14 FOMAL LOUNGE

GF-FCU-15 POOL HOUSE


SCHEDULE OF GRILLE / LINEAR DIFFUSER
HVAC REQUIREMENT
AIR FLOW
SAD/RAD Quantity (L/S) TYPE DIRECTION
EACH LENGTH (m)

LINEAR
550X200X200(H) 1 20 BOTTOM 0.55
DIFFUSER
LINEAR
1000X200X200(H) 1 40 BOTTOM 1
DIFFUSER
750X150(H) 4 84 GRILL SIDE

LINEAR
550X200X200(H) 1 20 BOTTOM 0.55
DIFFUSER

LINEAR
1000X200X200(H) 1 31 BOTTOM 1
DIFFUSER
750X150(H) 2 158 GRILL SIDE
CEILING
150X150 1 20 BOTTOM
DIFFUSER
LINEAR
550X200X200(H) 1 20 BOTTOM 0.55
DIFFUSER
LINEAR
1000X200X200(H) 2 108 BOTTOM 1
DIFFUSER
LINEAR
550X200X200(H) 1 25 BOTTOM 0.55
DIFFUSER
LINEAR
500X200X200(H) 2 25 BOTTOM 0.5
DIFFUSER

LINEAR
870X200X200(H) 2 80 BOTTOM 0.87
DIFFUSER
750X150(H) 1 200 GRILL SIDE
300X150(H) 1 43 GRILL SIDE
LINEAR
1000X200X200(H) 3 70 BOTTOM 1
DIFFUSER
900X150(H) 2 200 GRILL SIDE
LINEAR
500X200X200(H) 1 43 BOTTOM 0.5
DIFFUSER
LINEAR
550X200X200(H) 1 23 BOTTOM 0.55
DIFFUSER
LINEAR
750X200X200(H) 2 50 BOTTOM 0.75
DIFFUSER
300X150(H) 4 61 GRILL SIDE
450X100(H) 6 67 GRILL SIDE
CEILING
300X300 2 183 BOTTOM
DIFFUSER
750X150(H) 4 105 GRILL SIDE
LINEAR
850X200X200(H) 2 57 BOTTOM
DIFFUSER 0.85
750X150(H) 4 91 GRILL SIDE
750X150(H) 4 133 GRILL SIDE
LINEAR
1250X200X200(H) 6 78 BOTTOM
DIFFUSER 1.25
HVAC REQUIREMENT
NO. OF L/S
SLOT/ CALCULA NC
SIZE TED

1 / 25mm 0.036 16-25

1 / 25mm 0.040 16-25

0.084 <15

1 / 25mm 0.036 16-25

1 / 25mm 0.031 <16

0.158 <15

<15

0.036 16-25

2/25mm 0.108 28-34

1 / 25mm 0.045 16-25

1 / 25mm 0.050 25-29

2/25mm 0.092 24-28

0.2 <15
0.043 <15

2/25mm 0.070 15-17

0.2 <16

2/25mm 0.086 24-28


1/ 25mm 0.042 16-25

2/25mm 0.067 15-17

0.061 <15
0.067 <15

26-33

0.105 <15

2/25mm 0.067 15-17

0.091 <15
0.133 <15

2/25mm 0.062 15-17