0% found this document useful (0 votes)
82 views6 pages

Isolated Footing

This document provides calculations for the design of a concrete footing to support a column. It includes sizing the footing, checking shear capacity and punching shear, calculating reinforcement requirements, and checking development lengths and load transfer to the column. Reinforcement and dimensions are provided to meet the design requirements.

Uploaded by

UMESH LAMICHHANE
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd

Topics covered

  • reinforcement calculation,
  • depth calculation,
  • bond stress,
  • material properties,
  • development length,
  • maximum bending moment,
  • load-bearing capacity,
  • spacing,
  • steel grade,
  • shear reinforcement calculatio…
0% found this document useful (0 votes)
82 views6 pages

Isolated Footing

This document provides calculations for the design of a concrete footing to support a column. It includes sizing the footing, checking shear capacity and punching shear, calculating reinforcement requirements, and checking development lengths and load transfer to the column. Reinforcement and dimensions are provided to meet the design requirements.

Uploaded by

UMESH LAMICHHANE
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd

Topics covered

  • reinforcement calculation,
  • depth calculation,
  • bond stress,
  • material properties,
  • development length,
  • maximum bending moment,
  • load-bearing capacity,
  • spacing,
  • steel grade,
  • shear reinforcement calculatio…

1.

Data
Size of column
Bc = 350 mm
Dc = 350 mm
Column Load (V) = 274.67 KN
Bearing Capacity (qa) = 123.35 KN/m2
Grade of Concrete (fck) = 20 Mpa
Grade of Steel (fy)= 500 Mpa

2.Calculation of size of footing


wt. of foundation = 27.47 KN
Total Load (P)= 302.13 KN
Area of footing = 2.449 m2
*Note:Taking the ratio of width and length of footing same as that of column dimensions

Size of footing
L= 1.565 m
B= 1.565 m
Provided (L) = 1.600 m
Provided (B) = 1.600 m

Upward reaction (q') = 160.937 KN/m

Max'm B.M. = 31.433 KN-m

3.Calculation for depth of footing


B.M. = 0.134 fckbd2
depth (d)= 108 mm
Provided depth (d) = 300 mm

4.Check for Shear


Per. Shear Strength (τc) = 0.25√fck 1.118 N/mm2
a) Punching shear
depth (d)= 300 mm
Punching shear(τ'V) = 0.441 N/mm2
Ok
Provided depth (d) = 300 mm
Overall Depth (D)= 350 mm
b) One way Shear (Calculation for no shear reinforcement)
depth (d) = 300 mm
Max'm S.F. = 52.305 KN
One way Shear (τv) = 0.174 N/mm2
Provided Ast = 0.2 %
β= 11.61
Concrete Shear strength (τc)= 0.326 N/mm2
Ok
Ast = 600 mm2

5.Calculation for reinforcement

Ast = 247 mm2


Ast required = 600 mm2
Provided, Size = 12 mm dia
Spacing = 150 mm c/c
Ast Provided= 754 mm2
Ok
Area of Steel Along width
B.M. = 31.433 KN-m
Ast = 600 mm2
Provided, Size = 12 mm dia
Spacing = 150 mm c/c
Ast Provided= 754 mm2
Ok

6.Development Length

Bond stress(τbd)= 1.920 N/mm2


Development length (Ld)= 680 mm
Available Ld along length = 575 mm
Provide Hook

7.Load Transfer from Column to Footing


Nominal bearing stress in column = 3.363 N/mm2
Allowable bearing stress = 0.45*fck
9.000 N/mm2
Now Excess load = 0.000 kN
Area of steel required As = 0 mm2
Minimum Ast = 0.5% of column area
612.5 mm2
Thus, area of steel for dowel bars = 613 mm2
Now
Bar extended
Nos dia Ast
8 16 1608
Available Ast for load transfer = 1608 mm2

Thus no additional dowel bars are required to transfer load


Additional Ast = No dowel bars are needed
1.Data
Size of column
Bc = 350 mm
Dc = 350 mm
Column Load (V) = 236.00 KN
Bearing Capacity (qa) = 123.35 KN/m2
Grade of Concrete (fck) = 20 Mpa
Grade of Steel (fy)= 500 Mpa

2.Calculation of size of footing


wt. of foundation = 23.60 KN
Total Load (P)= 259.60 KN
Area of footing = 2.105 m2
*Note:Taking the ratio of width and length of footing same as that of column dimensions

Size of footing
L= 1.451 m
B= 1.451 m
Provided (L) = 1.500 m
Provided (B) = 1.500 m

Upward reaction (q') = 157.333 KN/m

Max'm B.M. = 26.009 KN-m

3.Calculation for depth of footing


B.M. = 0.134 fckbd2
depth (d)= 99 mm
Provided depth (d) = 300 mm

4.Check for Shear


Per. Shear Strength (τc) = 0.25√fck 1.118 N/mm2
a) Punching shear
depth (d)= 300 mm
Punching shear(τ'V) = 0.369 N/mm2
Ok
Provided depth (d) = 300 mm
Overall Depth (D)= 350 mm
b) One way Shear (Calculation for no shear reinforcement)
depth (d) = 300 mm
Max'm S.F. = 43.267 KN
One way Shear (τv) = 0.144 N/mm2
Provided Ast = 0.2 %
β= 11.61
Concrete Shear strength (τc)= 0.326 N/mm2
Ok
Ast = 600 mm2

5.Calculation for reinforcement

Ast = 203 mm2


Ast required = 600 mm2
Provided, Size = 12 mm dia
Spacing = 150 mm c/c
Ast Provided= 754 mm2
Ok
Area of Steel Along width
B.M. = 26.009 KN-m
Ast = 600 mm2
Provided, Size = 12 mm dia
Spacing = 150 mm c/c
Ast Provided= 754 mm2
Ok

6.Development Length

Bond stress(τbd)= 1.920 N/mm2


Development length (Ld)= 680 mm
Available Ld along length = 525 mm
Provide Hook

7.Load Transfer from Column to Footing


Nominal bearing stress in column = 2.890 N/mm2
Allowable bearing stress = 0.45*fck
9.000 N/mm2
Now Excess load = 0.000 kN
Area of steel required As = 0 mm2
Minimum Ast = 0.5% of column area
612.5 mm2
Thus, area of steel for dowel bars = 613 mm2
Now
Bar extended
Nos dia Ast
8 16 1608
Available Ast for load transfer = 1608 mm2

Thus no additional dowel bars are required to transfer load


Additional Ast = No dowel bars are needed