1.
Data
Size of column
Bc = 350 mm
Dc = 350 mm
Column Load (V) = 274.67 KN
Bearing Capacity (qa) = 123.35 KN/m2
Grade of Concrete (fck) = 20 Mpa
Grade of Steel (fy)= 500 Mpa
2.Calculation of size of footing
wt. of foundation = 27.47 KN
Total Load (P)= 302.13 KN
Area of footing = 2.449 m2
*Note:Taking the ratio of width and length of footing same as that of column dimensions
Size of footing
L= 1.565 m
B= 1.565 m
Provided (L) = 1.600 m
Provided (B) = 1.600 m
Upward reaction (q') = 160.937 KN/m
Max'm B.M. = 31.433 KN-m
3.Calculation for depth of footing
B.M. = 0.134 fckbd2
depth (d)= 108 mm
Provided depth (d) = 300 mm
4.Check for Shear
Per. Shear Strength (τc) = 0.25√fck 1.118 N/mm2
a) Punching shear
depth (d)= 300 mm
Punching shear(τ'V) = 0.441 N/mm2
Ok
Provided depth (d) = 300 mm
Overall Depth (D)= 350 mm
b) One way Shear (Calculation for no shear reinforcement)
depth (d) = 300 mm
Max'm S.F. = 52.305 KN
One way Shear (τv) = 0.174 N/mm2
Provided Ast = 0.2 %
β= 11.61
Concrete Shear strength (τc)= 0.326 N/mm2
Ok
Ast = 600 mm2
5.Calculation for reinforcement
Ast = 247 mm2
Ast required = 600 mm2
Provided, Size = 12 mm dia
Spacing = 150 mm c/c
Ast Provided= 754 mm2
Ok
Area of Steel Along width
B.M. = 31.433 KN-m
Ast = 600 mm2
Provided, Size = 12 mm dia
Spacing = 150 mm c/c
Ast Provided= 754 mm2
Ok
6.Development Length
Bond stress(τbd)= 1.920 N/mm2
Development length (Ld)= 680 mm
Available Ld along length = 575 mm
Provide Hook
7.Load Transfer from Column to Footing
Nominal bearing stress in column = 3.363 N/mm2
Allowable bearing stress = 0.45*fck
9.000 N/mm2
Now Excess load = 0.000 kN
Area of steel required As = 0 mm2
Minimum Ast = 0.5% of column area
612.5 mm2
Thus, area of steel for dowel bars = 613 mm2
Now
Bar extended
Nos dia Ast
8 16 1608
Available Ast for load transfer = 1608 mm2
Thus no additional dowel bars are required to transfer load
Additional Ast = No dowel bars are needed
1.Data
Size of column
Bc = 350 mm
Dc = 350 mm
Column Load (V) = 236.00 KN
Bearing Capacity (qa) = 123.35 KN/m2
Grade of Concrete (fck) = 20 Mpa
Grade of Steel (fy)= 500 Mpa
2.Calculation of size of footing
wt. of foundation = 23.60 KN
Total Load (P)= 259.60 KN
Area of footing = 2.105 m2
*Note:Taking the ratio of width and length of footing same as that of column dimensions
Size of footing
L= 1.451 m
B= 1.451 m
Provided (L) = 1.500 m
Provided (B) = 1.500 m
Upward reaction (q') = 157.333 KN/m
Max'm B.M. = 26.009 KN-m
3.Calculation for depth of footing
B.M. = 0.134 fckbd2
depth (d)= 99 mm
Provided depth (d) = 300 mm
4.Check for Shear
Per. Shear Strength (τc) = 0.25√fck 1.118 N/mm2
a) Punching shear
depth (d)= 300 mm
Punching shear(τ'V) = 0.369 N/mm2
Ok
Provided depth (d) = 300 mm
Overall Depth (D)= 350 mm
b) One way Shear (Calculation for no shear reinforcement)
depth (d) = 300 mm
Max'm S.F. = 43.267 KN
One way Shear (τv) = 0.144 N/mm2
Provided Ast = 0.2 %
β= 11.61
Concrete Shear strength (τc)= 0.326 N/mm2
Ok
Ast = 600 mm2
5.Calculation for reinforcement
Ast = 203 mm2
Ast required = 600 mm2
Provided, Size = 12 mm dia
Spacing = 150 mm c/c
Ast Provided= 754 mm2
Ok
Area of Steel Along width
B.M. = 26.009 KN-m
Ast = 600 mm2
Provided, Size = 12 mm dia
Spacing = 150 mm c/c
Ast Provided= 754 mm2
Ok
6.Development Length
Bond stress(τbd)= 1.920 N/mm2
Development length (Ld)= 680 mm
Available Ld along length = 525 mm
Provide Hook
7.Load Transfer from Column to Footing
Nominal bearing stress in column = 2.890 N/mm2
Allowable bearing stress = 0.45*fck
9.000 N/mm2
Now Excess load = 0.000 kN
Area of steel required As = 0 mm2
Minimum Ast = 0.5% of column area
612.5 mm2
Thus, area of steel for dowel bars = 613 mm2
Now
Bar extended
Nos dia Ast
8 16 1608
Available Ast for load transfer = 1608 mm2
Thus no additional dowel bars are required to transfer load
Additional Ast = No dowel bars are needed