QP STANDARD FOR NON DESTRUCTIVE TESTING
Part 2 : Radiographic Testing
(Addendum to ASME V-2013, Articles 1 and 2)
DOC. No. QP-STD-R-008-2 Rev. 1
T-232 INTENSIFYING SCREENS
Intensifying screens shall be as follow:
Radiation Source Screen Front Screen Back Screen
Material Thickness (mm) Thickness (mm)
X-Ray
< 120 KV Lead None 0.1min.
120 to 250 KV Lead 0.02 to 0.125 0.1min.
250 KV to 400KV Lead 0.05 to 0.16 0.1min.
Gamma Ray
Iridium Ir-192 Lead 0.13 mm to 0.16 0.16 min.
Cobalt CO-60 Steel, Copper * As per the As per the
qualified and qualified and
approved approved
procedure procedure
Selenium Se-75 Lead 0.125 0.125
*Other materials can be used as per the qualified and approved procedure.
T-233.1 STANDARD IQI DESIGN
IQI for welds shall be wire type.
T-234 FACILITIES FOR VIEWING OF RADIOGRAPHS
Add the following:
Densitometers shall be used to measure the density of the film. The densitometer shall
be calibrated in accordance with ASTM SE-1079.
Radiographic viewers shall meet the minimum requirements set forth in ISO 5580.
T-271 RADIOGRAPHIC TECHNIQUE
When using more than one film, there shall be a minimum 20 mm overlap of adjacent
film coverage.
Radiographs of repair areas shall overlap onto the original weld at either end by a
minimum of 50 mm
T-272 RADIATION ENERGY
- However, X-Ray
shall be used in radiography of welds in prefabrication / workshops and pipelines field
welding. However, using of Gamma Ray shall be supported by proper technical
justification and written approval from QP.
T-274.2 GEOMETRIC UNSHARPNESS LIMITATIONS
Geometric unsharpness shall not exceed those limits given in the following table:
Radiation Source Unsharpness (mm)
X-Ray 0.2
Gamma Ray 0.4
Doc. File No.: STD.R.008-2.R1 Page 10 of 14 Custodian: QA