BASIC SPECIFICATIONS
AIR CLEANERS – Dry type with rain shield and service indicators.
BARRING DEVICE – Manual.
BEARINGS – Heavy duty, replaceable, precision type.
BREATHER – Closed system.
CONNECTING RODS – Forged steel, rifle drilled.
COOLING SYSTEM – Choice of mounted radiator with pusher fan, core guard and duct adaptor, heat
VHP7100GSI/GSID
exchanger with surge tank, or connection for remote radiator cooling.
CRANKCASE – Integral crankcase and cylinder frame.
CRANKSHAFT – Counterweighted, forged steel, dynamically balanced, with sealed viscous vibration damper.
CYLINDER HEADS – Interchangeable valve–in–head type. Two hard faced intake and two hard faced
exhaust valves per cylinder. Hard faced intake and exhaust valve seat inserts.
CYLINDERS - 9.375″ (238 mm) bore x 8.5″ (216 mm) stroke. Removable wet cylinder liners. Number of
cylinders - Twelve. Gas Enginator ®
ENGINATOR BASE – Engine, generator and radiator or heat exchanger are mounted and aligned on a welded
steel, wide flange base, designed for solid mounting on an inertia block, with standard through–base holes Generating System
for lifting.
ENGINE PROTECTION SHUTDOWN CONTACTS – For high water temperature, low oil pressure, high intake 840 - 1350 kW
manifold temperature (standard engine mounted thermocouples with two thermocouple relays – shipped
loose), and overspeed (electronic speed switch – shipped loose). Also includes engine detonation sensing,
alarm and shutdown, as standard. (See separate description of Detonation Sensing Module.) Two on/off
pushbuttons are supplied, one on each side of the engine. Use all of the above in conjunction with a DC
control panel for unit shutdown, (reference WPS Engomatic® controls).
Note: DC shutdown control panel is not supplied as standard.
EXHAUST SYSTEM – Water cooled exhaust manifold with single vertical exhaust at rear. Flexible stainless
steel exhaust connection 8″ (203 mm) long with 8″ outlet flange.
FUEL SYSTEM – Dual natural gas carburetors and Fisher gas regulators (Model 99 for GSI, model
133L for GSID). 24V DC gas solenoid valve (shipped loose). 20 – 25 psi (1.4 – 1.7 bar) gas
pressure recommended on GSI; 12″ – 60 psi (304 mm – 4 bar) recommended on GSID.
Single fuel connection point for GSI. Two connection points on GSID.
GENERATOR – Open, dripproof, direct connected, fan cooled, 2/3 pitch, A.C. revolving field
type, single bearing generator with brushless exciter, short circuit sustain (PMG type
maintains 270% of rated generator current for up to 10 seconds on 105° C temperature rise
generators; maintains 250% of current on 130° C rise generators) and damper windings.
TIF and Deviation Factor within NEMA MG-1.32. Voltage 480/277, 3 phase, 4 wire, Wye
60 Hz and 400/230, 3 phase, 4 wire, Wye 50 Hz. Other voltages are available, consult
factory. Insulation material NEMA Class F. Temperature rise within NEMA (105° C) for
continuous power duty, within NEMA (130° C) for standby duty. All generators are rated at
0.8 Power Factor, are mounted on the engine flywheel housing and have multiple steel disc flexible
coupling drive. All continuous power gensets have 10% overload capacity.
GOVERNOR – Woodward Model EG3P electric actuator (mounted) and magnetic pickup (mounted). Requires Enginator shown with options.
a separate electric governor control, Woodward Model 2301D or similar, (not included).
IGNITION – Waukesha Custom Engine Control Ignition Module. Electronic digital ignition system. Model VHP7100GSI
INSTRUMENT CONNECTIONS – Type K thermocouples for jacket water temperature, lube oil temperature Turbocharged and Intercooled
and intake manifold temperature wired to a common junction box. A single header block for lube oil Gas Fueled Enginator
pressure and intake manifold pressure is engine mounted. Recommend optional Model 4000 remote engine
instrument panel, especially for continuous power installations.
INTERCOOLER – Air to water.
JUNCTION BOXES – Separate AC, DC, and instrument/thermocouple junction boxes for engine wiring and
external connections. SPECIFICATIONS
LUBRICATION – Full pressure, positive displacement pump. Full flow oil filter (shipped loose) and flexible
connections. 50 or 60 Hz, 230 volt AC, single phase electric motor driven intermittent prelube pump with Engine Jacket Water
motor starter (other voltages can be specified).
Note: External control logic required to start/stop prelube pump. L7042GSI, Capacity
OIL COOLER – Shell and tube type (mounted). Four Cycle, 100 gal.
OIL PAN – Cast alloy iron base type with removable doors. Overhead Valve (379 L)
PAINT – Oilfield Orange.
PISTONS – Aluminum with floating pin. Oil cooled. Cylinders Starting System
STARTING EQUIPMENT – Two 24V DC electric starting motors, crank termination switch (shipped loose). V 12 24 V Electric
TURBOCHARGERS – Dry type, wastegate controlled.
VOLTAGE REGULATOR – SCR static automatic type providing 1% regulation from no load to full load, single Piston Displacement Fuel LHV
phase sensing and automatic subsynchronous speed protection. Includes voltage adjustment rheostat 7040 cu. in. 900 Btu/ft3
(shipped loose). (115 L) (33.5 J/cm3)
WATER CIRCULATING SYSTEM
Auxiliary Circuit – For oil cooler and intercooler. Pump is belt driven from crankshaft pulley. Bore & Stroke Lube Oil Capacity
Engine Jacket – Belt driven water pump, 175 – 180° F (79 – 82° C) thermostatic temperature regulation 9.375″ x 8.5″ 90 gal.
full flow bypass. Single ANSI flange connections for inlet and outlet on water connect units. (238 x 216 mm) (340 L)
WAUKESHA CUSTOM ENGINE CONTROL DETONATION SENSING MODULE (DSM) – Includes
individual cylinder sensors, Detonation Sensing Module, and filter, all factory mounted. Device is Compression Ratio
compatible with Waukesha CEC Ignition Module only. 24V DC power is required. The DSM meets 8:1
Canadian Standards Association Class I, Division 2, Group D, hazardous location requirements.
PERFORMANCE DATA: VHP7100GSI GAS ENGINATOR® GENERATING SYSTEM
CONTINUOUS POWER* STANDBY POWER
HEAT EXCHANGER COOLING 1200 rpm 1000 rpm 1200 rpm 1000 rpm
Intercooler Water: 85°F (29°C)
60 Hz 50 Hz 60 Hz 50 Hz
kW RATING 1100 920 1350 1125
Fuel Consumption x 1000 Btu/h (kW) 12234 (3586) 9972 (2923) 14563 (4268) 11875 (3480)
Jacket Water x 1000 Btu/h (kW) 3543 (1038) 2955 (866) 4125 (1209) 3434 (1006)
Intercooler x 1000 Btu/h (kW) 365 (107) 229 (67) 575 (169) 359 (105)
Lube Oil x 1000 Btu/h (kW) 356 (104) 314 (92) 389 (114) 344 (101)
Heat Radiated x 1000 Btu/h (kW) 854 (250) 761 (223) 813 (238) 708 (207)
Exhaust Heat** x 1000 Btu/h (kW) 3363 (986) 2574 (754) 4055 (1188) 3192 (936)
Exhaust Flow lb/h (kg/h) 10467 (4748) 8537 (3872) 12607 (5719) 10286 (4666)
Exhaust Temperature °F (°C) 1161 (627) 1090 (588) 1177 (636) 1121 (605)
Induction Air Flow scfm (m3/min) 2297 (65) 1874 (53) 2769 (78) 2259 (64)
CONTINUOUS POWER* STANDBY POWER
WATER CONNECTION COOLING 1200 rpm 1000 rpm 1200 rpm 1000 rpm
Intercooler Water: 130°F (54°C) 60 Hz 50 Hz 60 Hz 50 Hz
kW RATING 1050 875 1300 1075
Fuel Consumption x 1000 Btu/h (kW) 11602 (3400) 9433 (2764) 13911 (4077) 11260 (3300)
Jacket Water x 1000 Btu/h (kW) 3499 (1025) 2892 (848) 4117 (1207) 3382 (991)
Intercooler x 1000 Btu/h (kW) 228 (67) 120 (35) 401 (118) 212 (62)
Lube Oil x 1000 Btu/h (kW) 350 (103) 308 (90) 382 (112) 338 (99)
Heat Radiated x 1000 Btu/h (kW) 846 (248) 766 (224) 878 (257) 781 (229)
Exhaust Heat** x 1000 Btu/h (kW) 3095 (907) 2362 (692) 3697 (1084) 2879 (844)
Exhaust Flow lb/h (kg/h) 9927 (4503) 8078 (3664) 12044 (5463) 9750 (4423)
Exhaust Temperature °F (°C) 1125 (607) 1058 (570) 1145 (618) 1096 (591)
Induction Air Flow scfm (m3/min) 2179 (62) 1773 (50) 2645 (75) 2141 (61)
CONTINUOUS POWER* STANDBY POWER
RADIATOR COOLING - MOUNTED 1200 rpm 1000 rpm 1200 rpm 1000 rpm
Intercooler Water: 130°F (54°C) 60 Hz 50 Hz 60 Hz 50 Hz
kW RATING 1000 840 1260 1050
Fuel Consumption x 1000 Btu/h (kW) 11395 (3340) 9315 (2730) 13868 (4064) 11201 (3283)
Jacket Water x 1000 Btu/h (kW) 3444 (1009) 2861 (839) 4106 (1203) 3366 (987)
Intercooler x 1000 Btu/h (kW) 215 (63) 115 (34) 397 (116) 209 (61)
Lube Oil x 1000 Btu/h (kW) 347 (102) 306 (90) 381 (112) 337 (99)
Heat Radiated x 1000 Btu/h (kW) 835 (245) 760 (223) 872 (255) 781 (229)
Exhaust Heat** x 1000 Btu/h (kW) 3040 (891) 2331 (683) 3686 (1080) 2862 (839)
Exhaust Flow lb/h (kg/h) 9740 (4418) 7968 (3614) 12004 (5445) 9696 (4398)
Exhaust Temperature °F (°C) 1123 (606) 1055 (568) 1145 (618) 1095 (591)
Induction Air Flow scfm (m3/min) 2138 (61) 1749 (50) 2637 (75) 2130 (60)
Radiator Air Flow scfm (m3/min) 112000 (3172) 92000 (2605) 122000 (3455) 97000 (2747)
Typical heat balance data is shown. Consult factory for guaranteed data.
*Continuous Power Rating: The highest electrical power output of the Enginator available for an unlimited number of hours per year, less maintenance. It is permissible to operate the
Enginator with up to 10% overload for two hours in each 24 hour period.
Standby Power Rating: This rating applies to those systems used as a secondary source of electrical power. This rating is the electrical power output of the Enginator (no overload) 24
hours a day, for the duration of the primary power source outage.
Rating Standard: The Waukesha Enginator power rating descriptions are in accordance to ISO 8528, DIN6271 and BS5514. It is also valid for ISO 3046/1-1995 with an engine
mechanical efficiency of 90% and Tcra (clause 10.0) is limited to ± 10° F (5° C).
**Heat rejection based on cooling exhaust gas to 77° F (25° C).
Cooling
Equipment L in (mm) W in (mm) H in (mm) Avg. Wt. lb (kg)
Heat Exchanger 218 (5540) 80 (2030) 108 (2740) 36000 (16330)
Water Cooler 201 (5110) 80 (2030) 108 (2740) 34000 (15425)
Radiator 238 (6050) 114 (2900) 138 (3500) 39750 (18030)
WAUKESHA POWER SYSTEMS WAUKESHA ENGINE Consult your local Waukesha Distributor for system application
WAUKESHA ENGINE DRESSER INDUSTRIAL PRODUCTS, B.V. assistance. The manufacturer reserves the right to change or
DRESSER, INC. Farmsumerweg 43, Postbus 330 modify without notice, the design or equipment specifications
as herein set forth without incurring any obligation either with
1000 West St. Paul Avenue 9900 AH Appingedam, The Netherlands
respect to equipment previously sold or in the process of con-
Waukesha, WI 53188-4999 Phone: (31) 596-652222 Fax: (31) 596-628111 struction except where otherwise specifically guaranteed by
Phone: (262) 547-3311 Fax: (262) 549-2795 the manufacturer.
waukeshaengine.dresser.com
Bulletin 8010 0402
Waukesha, Enginator and Engomatic are trademarks/registered trademarks of Waukesha Engine, Dresser, Inc. Copyright 2001 Dresser, Inc.