Amendment No. 1 to IS 458:2021 specifies various updates to tables and notes regarding precast concrete pipes, including new entries and substitutions for existing data. Key changes include adjustments to dimensions, tolerances, and inspection procedures across multiple tables. This amendment aims to enhance the clarity and accuracy of the specifications for precast concrete pipes.

Uploaded by

Feraz ahmad Jami
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
99 views2 pages

458 Amendment

Amendment No. 1 to IS 458:2021 specifies various updates to tables and notes regarding precast concrete pipes, including new entries and substitutions for existing data. Key changes include adjustments to dimensions, tolerances, and inspection procedures across multiple tables. This amendment aims to enhance the clarity and accuracy of the specifications for precast concrete pipes.

Uploaded by

Feraz ahmad Jami
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd

AMENDMENT NO.

1 MARCH 2024

TO

IS 458 : 2021 PRECAST CONCRETE PIPES (WITH AND WITHOUT REINFORCEMENT) —


SPECIFICATION

( Fifth Revision )

(Page 11, Table 5) — Add following at the end of the table before note:

(1) (2) (3) (4) (5) (6) (7)


2 600 240 12 + 2 14.88 146.61 124.54 186.81

(Page 14, Table 8) — Add following at the end of the table before note:

(1) (2) (3) (4) (5) (6) (7)


2 200 210 12 + 2 14.88 125.28 142.20 213.30
2 400 225 12 + 2 14.88 154.94 155.00 232.50
2 600 240 12 + 2 14.88 181.25 166.70 250.00

[Page 20, Table 13, entry of col (15) against 700] — Substitute ’52’ for ‘47’.

(Page 20, Table 13, Note 1) — Substitute the following for the existing:

‘The outside diameter of spigot and inside diameter of socket shall be checked as per 10.2.2.’

[Page 21, Table 13A, entry of col (15) against 700] — Substitute ’52’ for ‘47’.

(Page 22, Table 13A, Note 2) — Substitute the following for the existing:

‘The procedure for the inspection is given in 10.2.2.’

(Page 22, Table 13A, Note 1) — Substitute the following for the existing:

‘The outside diameter of spigot and inside diameter of socket shall be checked as per 10.2.2.’

(Page 24, Table 14, Note 1) — Substitute the following for the existing:

‘The outside diameter of spigot and inside diameter of socket shall be checked as per 10.2.2.’

(Page 25, Table 15A, Note 5) — Substitute the following for the existing:

‘Tolerance on 𝐷3 ± 4, 𝐿2 ± 2.’

(Page 26, Table 15B, heading) — Substitute the heading of the table with the following:

‘Table 15B Spigot and Socket Dimensions for NP-3 Reinforced and Unreinforced + NP-4 Reinforced
Pipes Made by Vibration Casting Process from 300 mm to 1 800 mm Diameter’.

Price Group 1
Amendment No. 1 to IS 458 : 2021

[Page 26, Table 15B, col (8) sub-heading] — Substitute ′𝑑s ' for '𝑑m ’.

(Page 27, Table 15B, Note 5) — Delete.

(Page 28, Table 15C) — Add following at the end of the table before note:

𝑑i 𝐺 𝑅 𝑇 𝑙t 𝐿b 𝑑s 𝐷m 𝐿m 𝑙s 𝑆 𝐷O 𝑑so 𝑑sp

2 600 ± 12 28 2 450 240 130 ± 4 130 ± 3 2 811 2 845 70 52 17 ± 1.5 3 080 ± 6 117.5 105.5

(Page 28, Table 15C, Note 4) — Substitute the following for the existing:

‘𝑙t , 𝐿b , 𝑑s , 𝐷m , 𝐿m , 𝑙s 𝑑so and 𝑑sp are nominal dimensions.’

(Page 32, Table 17, Note 1) — Substitute the following for the existing:

‘The outside diameter of spigot and inside diameter of socket shall be checked as per 10.2.2.’

(Page 34, Table 18, Note 1) — Substitute the following for the existing:

‘The outside diameter of spigot and inside diameter of socket shall be checked as per 10.2.2.’

(Page 35, Table 18A) — Substitute the heading of the table with the following:

‘Table 18A Spigot and Socket Dimensions of P2 Class Pipes (Rubber Ring Roll on Joint) Pipes Made by
Vibrated Casting Process’.

(Page 36, Table 18A, Note 1) — Substitute the following for the existing:

‘The outside diameter of spigot and inside diameter of socket shall be checked as per 10.2.2.’

(Page 38, Table 19, Note 1) — Substitute the following for the existing:

‘The outside diameter of spigot and inside diameter of socket shall be checked as per 10.2.2.’

(Page 39, Table 19A, Note 1) — Substitute the following for the existing:

‘The outside diameter of spigot and inside diameter of socket shall be checked as per 10.2.2.’

(Page 44, clause 8.2, Table, Note) — Add the following at the end:

‘The above tolerances shall be applicable only where the tolerances are not mentioned.’

(Page 45, clause 10.2.2) — Substitute the following for the existing:

‘The diameter of spigot and socket shall be checked at four locations, equally spaced throughout the
circumference of pipe. The dimensions which are mentioned as nominal in this Indian standard, should
be for reporting purpose only. All the figures given with the tables are typical in nature and it is for
illustration purpose only.’

(Page 45, Table 23, Note) — Delete.

(CED 53)