Proportional Solenoid Valve Catalogue 20240819
Proportional Solenoid Valve Catalogue 20240819
1
Proportional valve YCLT11
Characteristics:
• Higher pressure,1 million cycles test
Reliable quality, ideal for high precision flow control
• Suitable for oxygen service, performance is verified
• Sensitive reaction, excellent adjustment range
• Compact design
Typical Applications:
Electrical parameters:
Coil Insulation: H
Electrical connection: 6.3*0.8 Plug
YCLT11(1F) YCLT11(2F) YCLT11(3F)
Protection class: IP65
Voltage: 12VDC,24VDC
*The appearance may change according to the specific situation of our
PWM frequency: PWM Frequency 1200-2000Hz
Hysteresis: ≤15%(max)
Flow regulation: Repetition≤1%;Sensitivity≤ 0.1%
0.4 8Bar 11
2.0 2Bar 48
Coil Data
2
Proportional valve YCLT11
Dimension
YCLT11(M5)
YCLT11(G1/8")
depth 8
YCLT11(1F)
outlet
Oring
Oring
YCLT11(2F)
3
Proportional valve YCLT11
YCLT11(3F)
Oring
quick fitting
YCLT11-SB91B
Max flow rate VS pressure & orifice:
Flow rate L/min
Pressure bar
4
Proportional valve YCLT11
Current-flow curve
Current mA Current mA
Note *: There may be slight differences in product flow due to individual differences and different pipeline conditions. Please refer to the pressure
flow curve and select products that fully meet the flow requirements according to the requirements, leaving a standard with margin to select the model.
5
Proportional valve YCLT21
Characteristics:
• Higherpressure,1 millioncycles test
Reliablequality,idealforhighprecisionflowcontrol
• Suitableforoxygenservice, performanceis verified
• Sensitivereaction,highprecision
• Compactdesign
Typical Applications:
• Ventilator
YCLT21(G1/8") YCLT21(G1/4")
• Injection equipment
• Pressure and flow rate control
• Mass flow controllerfor anesthesiadelivery
Electrical parameters:
Coil Insulation: H
Electrical connection: 6.3*0.8 Plug
Protection class: IP65
Voltage: 12VDC,24VDC YCLT21(1F) YCLT21(2F) YCLT21(3F)
0.8 7Bar 41
1.0 6Bar 48
6
Proportional valve YCLT21
Coil Data
Dimension
YCLT21B(G1/8") YCLT21G(G1/8")
depth 6 depth 6
YCLT21B(G1/4") YCLT21G(G1/4")
depth 6
depth 6
YCLT21B(1F) YCLT21G(1F)
Oring Oring
thorough hole × × Oring Oring
thorough hole × ×
7
Proportional valve YCLT21
YCLT21B(2F) YCLT21G(2F)
Oring Oring
thorough hole thorough hole
× ×
Oring Oring
× ×
YCLT21B(3F) YCLT21G(3F)
thorough hole
thorough hole
YCLT21-SC11B
Max flow rate VS pressure & orifice:
8
Proportional valve YCLT21
Current-flow curve
YCLT21B(low pressure version):
Current mA Current mA
Current mA Current mA
9
Proportional valve YCLT21
Current mA Current mA
Note *: There may be slight differences in product flow due to individual differences and different pipeline conditions. Please refer to the pressure
flow curve and select products that fully meet the flow requirements according to the requirements, leaving a standard with margin to select the model.
10
Proportional valve YCLT33
Characteristics:
• Special magnetic material heat treatment and special design of flat butterfly spring.
• Ultra small, light weight, low power consumption (Max.2W), high-performance
single power supply.
• Higher working pressure range, 10 millions cycles tests, performance is verified.
• Hysteresis (Min as low as 6%),excellent repetition (< 1%),
ideal for high precision flow control.
Typical Applications:
• Gas chromatographic analyzer
• Mass spectrum analyzer
• Oxygen generator/reservoir
• Ventilator
• Anesthesia delivery instrument
• Mass flow controller
• Pressure and flow control
Electrical parameters:
Coil Insulation: F
Electrical connection: 24 AWG L=500mm
Protection class: IP50
YCLT33(2F) YCLT33(3FB)
Voltage: 12VDC,24VDC
PWM frequency: PWM Frequency >4000Hz
*The appearance may change according to the specific situation of our
Hysteresis: Hysteresis 6%(min), ≤15%(full scale)
Flow regulation: Repetition≤1%;Sensitivity ≤0.1%
0.08 10bar ——
0.15 10bar ——
G(NPT)1/8'' 0.25 10bar ——
nuetral
gas
G(NPT)1/4'' (Filter level:
0.6 10bar ——
0.08mm :
VITON BRASS 5μ);
YCLT33 2/2NC 1F(1 Flange) 0.8 10bar —— YJ2B 20ms
NBR SUS316L 0.2-0.6mm :
2F(2 Flange) 1.0 7bar —— 17μ);
0.8mm≥ :
3F(3 Flange) 1.2 6bar —— 40μ))
1.4 5bar ——
1.6 4bar ——
Coil Data
11
Proportional valve YCLT33
Dimension
depth 8
orifice depth 10
depth 8
orifice depth 10
YCLT33(2F) YCLT33(3F)
12
Proportional valve YCLT33
YCLT33(5F)
thorough hole
Current-flow curve
Current mA Current mA
13
Proportional valve YCLT33
Note *: There may be slight differences in product flow due to individual differences and different pipeline conditions. Please refer to the pressure
flow curve and select products that fully meet the flow requirements according to the requirements, leaving a standard with margin to select the model.
14
Proportional valve YCLT51
Characteristics:
• Flow of air and inert gas can be controlled proportionally
by changing the input electrical signal of the coil
• Maximum flow rate up to 200L/min, maximum pressure up to 60psi
• High repeatability and precision within its operating range
• Low power consumption, small size, reducing quality
generated during long-term use
Typical Applications:
• Ventilator
• Oxygen generator/reservoir
• Anesthesia delivery instrument
• Mass flow controller
• Pressure and flow contro
Electrical parameters:
Coil Insulation: F
Electrical connection: 24 AWG L=500mm
Protection class: IP50
*The appearance may change according to the specific situation of our
Voltage: 12VDC,24VDC
PWM frequency: PWM Frequency >4000Hz
Hysteresis: Hysteresis ≤15%(full scale)
Flow regulation: Repetition≤1%;Sensitivity ≤0.1%
BRASS
YCLT51 —— F(Flange) 5.0 —— —— VITON YJ2B 20-40ms nuetral gas
SUS316L
Coil Data
Type Resistance (Ω) Voltage (V) Max current(A) Maximum power(W)
15
Proportional valve YCLT51
Dimension
thorough hole
Ori n g
O-ring size(2 for each valve body) Cross head screw M3x20(2 for each valve body)
16
Proportional valve YCLT51
YCLT51-Orifice Φ5.0mm
Current mA
Current-flow curve
YCLT51
Flow rate L/min
Pressure bar
Note *: There may be slight differences in product flow due to individual differences and different pipeline conditions. Please refer to the pressure
flow curve and select products that fully meet the flow requirements according to the requirements, leaving a standard with margin to select the model.
17
Proportional valve YCLT71
Characteristics:
• Higherpressure,1 millioncycles test
Reliablequality,idealforhighprecisionflowcontrol
• Suitableforoxygenservice, performanceis verified
• Sensitivereaction,highprecision
• Compactdesign
Typical Applications:
• Ventilator
• Oxygen generator/reservoir
• Anesthesia delivery instrument
• Mass flow controller
• Pressure and flow contro
Coil Insulation: H
Electrical connection: 6.3*0.8 Plug *The appearance may change according to the specific situation of our
1.2 6 82
1.6 5 120
2.0 4 148
YCLT71B
2.4 2.5 130
(low
pressure 3.0 1.75 130
version)
M5 4.0 1 117
G(NPT)1/8'' BARSS nuetral gas
1.2 12 108
VITON 20-40ms and
2/2NC 1F(1 Flange) SUS316L SC92B
NBR
1.6 10 190 AL liquid
2F(2 Flange)
3F(3 Flange) 2.0 8 290
18
Proportional valve YCLT71
Coil Data
Dimension
YCLT71B/G(G1/4)
depth 8
YCLT71B/G(G3/8)
YCLT71B/G(1F)
Oring Oring
× ×
19
Proportional valve YCLT71
YCLT71-SB92B
Max flow rate VS pressure & orifice:
Current-flow curve
20
Proportional valve YCLT71
Current mA Current mA
Note *: There may be slight differences in product flow due to individual differences and different pipeline conditions. Please refer to the pressure
flow curve and select products that fully meet the flow requirements according to the requirements, leaving a standard with margin to select the model.
21
Proportional valve YCLT81
Characteristics:
• Higherpressure,1 millioncycles test
Reliablequality,idealforhighprecisionflowcontrol
• Suitableforoxygenservice, performanceis verified
• Sensitivereaction,highprecision
• Compactdesign
Typical Applications:
• Mass flow controller
• Pressure and flow control
• Used for high demand regulation conditions
Electrical parameters:
Coil Insulation: H YCLT81(brass) YCLT81(SS304)
Electrical connection: 6.3*0.8 Plug
Protection class: IP65 *The appearance may change according to the specific situation of our
Voltage: 12VDC,24VDC
PWM frequency: PWM Frequency 600-800Hz
Hysteresis: ≤15%(max)
Flow regulation: Repetition≤1%;Sensitivity≤ 0.1%
Coil Data
Type Resistance (Ω) Voltage (V) Max current(A) Maximum power(W)
22
Proportional valve YCLT81
Dimension
YCLT81(G3/8)
depth 8
depth 15
YCLT81(G1/2)
depth 8
depth 15
YCLT81-SE71B
Max flow rate VS pressure & orifice:
YCLT81G
Flow rate L/min
Pressure bar
23
Proportional valve YCLT81
Current-flow curve
Current mA Current mA
Current mA Current mA
Note *: There may be slight differences in product flow due to individual differences and different pipeline conditions. Please refer to the pressure
flow curve and select products that fully meet the flow requirements according to the requirements, leaving a standard with margin to select the model.
24
Proportional PWM Controller
Working mechanism:
After the proportional valve controller is powered on, the controller continuously supplies
power and power off to the proportional valve at a certain frequency through the switching
device, thereby changing the current flowing through the proportional valve. By collecting
this current signal and changing the on/off frequency, the proportional valve constant
current drive function is achieved under voltage source power supply.condtions.
Method or application:
The controller uses standard signals from industrial sites for control (0-5V voltage, 0-10V
voltage, 0-20mA current, 4-20mA current, with one of the control signals selected) to
proportionally adjust the valve body current.
When using the controller, it is necessar y to connect the power line, ground wire, signal
wire, and connect the proportional valve wire to the proportional valve. After selecting
the appropriate voltage based on the proportional valve model and powering it on, the
adjustment of the proportional valve opening can be achieved by adjusting the current or
voltage of the signal line.
For example, a certain controller has an input of 0-5V and an output current of 1A. When
the control signal is detected to be 4V (80%), the controller executes the action. At this
time, the current flowing through the proportional valve is 0.8A (80%), and the flow rate
can be obtained by quer ying the proportional valve specification book .
Time Time
Comparison:PWM Controller
Totally open
Flowrate increasing
Start open
25
Proportional PWM Controller
Differences:
There are only two states: on and off, which are manifested Powered on, solenoid valve working;
Solenoid valve externally as on and off states Power off, solenoid valve stop
Can continuously and proportionally adjust the opening, and Using continuously adjustable current
proportional valve can control the pressure and flow rate of the fluid. to control the opening of the
proportional valve
Due to conventional industrial equipment only providing a fixed voltage source (such as DC 24V) and not equipped with an adjustable
current source (such as 0-1A current source) Therefore, customers need to use a proportional valve controller or design their own
proportional valve control circuit when using proportional valves
Wiring Instructions:
yellow signal line - signal line - Ground Optional, current control signal
26