0% found this document useful (0 votes)
210 views27 pages

Proportional Solenoid Valve Catalogue 20240819

The document is a product catalog for precision proportional solenoid valves manufactured by Yuyao Yongchuang Solenoid Valve Co., Ltd. It details various models, including their characteristics, typical applications, electrical parameters, technical data, and coil specifications. The catalog emphasizes the valves' reliability, high precision, and suitability for various applications such as ventilators and mass flow controllers.

Uploaded by

Rega Primasta
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
210 views27 pages

Proportional Solenoid Valve Catalogue 20240819

The document is a product catalog for precision proportional solenoid valves manufactured by Yuyao Yongchuang Solenoid Valve Co., Ltd. It details various models, including their characteristics, typical applications, electrical parameters, technical data, and coil specifications. The catalog emphasizes the valves' reliability, high precision, and suitability for various applications such as ventilators and mass flow controllers.

Uploaded by

Rega Primasta
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd

Precision proportional solenoid valve

YUYAO YONGCHUANG SOLENOID VALVE CO.,LTD.

No.65 Beixing Rd.Mazhu,Yuyao,Zhejiang,China 315400 www.ycdcf.com


> PRODUCT CATALOGUE <

YCLT11 / Proportional valve P2-5

YCLT21 / Proportional valve P6-10

YCLT33 / Micro proportional valve P11-14

YCLT51 / Proportional valve P15-17

YCLT71 / Proportional valve P18-21

YCLT81 / Proportional valve P22-24

YCPW11 / Proportional PWM Controller P25-26

1
Proportional valve YCLT11

Characteristics:
• Higher pressure,1 million cycles test
Reliable quality, ideal for high precision flow control
• Suitable for oxygen service, performance is verified
• Sensitive reaction, excellent adjustment range
• Compact design

Typical Applications:

• Ventilator YCLT11(G1/8") YCLT11(M5)


Injection equipment
• Anaesthetic delivery
• Mass flow controller
• Pressure and flow rate control

Electrical parameters:
Coil Insulation: H
Electrical connection: 6.3*0.8 Plug
YCLT11(1F) YCLT11(2F) YCLT11(3F)
Protection class: IP65
Voltage: 12VDC,24VDC
*The appearance may change according to the specific situation of our
PWM frequency: PWM Frequency 1200-2000Hz
Hysteresis: ≤15%(max)
Flow regulation: Repetition≤1%;Sensitivity≤ 0.1%

Technical data *customized service is on option

Orifice Max pressure Max flow Response


PART NO Model Port size Seal Body Coil Medium
(mm) (Bar) (L/min) time

0.4 8Bar 11

G(NPT)1/8'' 0.6 6Bar 18

G(NPT)1/4'' 0.8 6Bar 36


nuetral gas
VITON BRASS
YCLT11 2/2NC 1F(1Flange) 1.0 6Bar 51 SB91B 20-40ms and
NBR SUS316L
liquid
2F(2Flange) 1.2 4Bar 44

3F(3Flange) 1.6 3Bar 45

2.0 2Bar 48

Working Temp.:-10℃~90℃ Ambient Temp.:-30℃~90℃

Coil Data

Type Resistance (Ω) Voltage (V) Max current(A) Maximum power(W)

SB91B-DC12V-2W 72Ω DC12V 0.15 2W

SB91B-DC24V-2W 289Ω DC24V 0.07 2W

SB91B-DC12V-4W 36Ω DC12V 0.28 4W

SB91B-DC24V-4W 144Ω DC24V 0.14 4W

SB91B-DC12V-6W 24Ω DC12V 0.4 6W

SB91B-DC24V-6W 96Ω DC24V 0.2 6W

2
Proportional valve YCLT11

Dimension

YCLT11(M5)

YCLT11(G1/8")

depth 8

YCLT11(1F)

outlet
Oring

Oring

YCLT11(2F)

Oring thorough hole

3
Proportional valve YCLT11

YCLT11(3F)

Oring
quick fitting

Pressure flow curve

YCLT11-SB91B
Max flow rate VS pressure & orifice:
Flow rate L/min

Pressure bar

4
Proportional valve YCLT11

Current-flow curve

YCLT11B-Orifice Φ0.4mm YCLT11B-Orifice Φ0.6mm


Flow rate L/min

Flow rate L/min


Current mA Current mA

YCLT11B-Orifice Φ0.8mm YCLT11B-Orifice Φ1.0mm


Flow rate L/min

Flow rate L/min

Current mA Current mA

YCLT11B-Orifice Φ1.2mm YCLT11B-Orifice Φ1.6mm YCLT11B-Orifice Φ2.0mm


Flow rate L/min

Flow rate L/min

Flow rate L/min

Current mA Current mA Current mA

Note *: There may be slight differences in product flow due to individual differences and different pipeline conditions. Please refer to the pressure
flow curve and select products that fully meet the flow requirements according to the requirements, leaving a standard with margin to select the model.

5
Proportional valve YCLT21

Characteristics:
• Higherpressure,1 millioncycles test
Reliablequality,idealforhighprecisionflowcontrol
• Suitableforoxygenservice, performanceis verified
• Sensitivereaction,highprecision
• Compactdesign

Typical Applications:

• Ventilator
YCLT21(G1/8") YCLT21(G1/4")
• Injection equipment
• Pressure and flow rate control
• Mass flow controllerfor anesthesiadelivery

Electrical parameters:
Coil Insulation: H
Electrical connection: 6.3*0.8 Plug
Protection class: IP65
Voltage: 12VDC,24VDC YCLT21(1F) YCLT21(2F) YCLT21(3F)

PWM frequency: PWM Frequency 1200-2000Hz


Hysteresis: ≤15%(max) *The appearance may change according to the specific situation of our

Flow regulation: Repetition≤1%;Sensitivity≤ 0.1%

Technical data *customized service is on option

Orifice Max pressure Max flow Response


PART NO Model Port size Seal Body Coil Medium
(mm) (Bar) (L/min) time

0.8 7Bar 41

1.0 6Bar 48

YCLT21B 1.2 5Bar 57


(low
1.6 4Bar 91
pressure
version) G(NPT)1/8''
2.0 3Bar 90
G(NPT)1/4'' 2.4 1.5Bar 70

1F(1 Flange) 3.0 1Bar 60 nuetral


2/2NC VITON BRASS
SC11B 20-40ms gas and
NBR SUS316L
2F(2 Flange) 0.8 12Bar 53 liquid

3F(3 Flange) 1.0 10Bar 70

YCLT21G 1.2 8Bar 86


(High
pressure 1.6 6.5Bar 126
version)
2.0 5Bar 155

2.4 3Bar 115

3.0 2Bar 107

Working Temp.:-10℃~90℃ Ambient Temp.:-30℃~90℃

6
Proportional valve YCLT21

Coil Data

Type Resistance (Ω) Voltage (V) Max current(A) Maximum power(W)

SC21B-DC12V-6.5W 22Ω DC12V 0.55 6.5W

SC21B-DC24V-6.5W 89Ω DC24V 0.25 6.5W

Dimension

YCLT21B(G1/8") YCLT21G(G1/8")

depth 6 depth 6

YCLT21B(G1/4") YCLT21G(G1/4")

depth 6

depth 6

YCLT21B(1F) YCLT21G(1F)

Oring Oring
thorough hole × × Oring Oring
thorough hole × ×

7
Proportional valve YCLT21

YCLT21B(2F) YCLT21G(2F)

Oring Oring
thorough hole thorough hole
× ×

Oring Oring
× ×

YCLT21B(3F) YCLT21G(3F)

thorough hole

thorough hole

Pressure flow curve

YCLT21-SC11B
Max flow rate VS pressure & orifice:

YCLT21B(low pressure version)-SC11B YCLT21G(High pressure version)-SC11B


Flow rate L/min

Flow rate L/min

Pressure bar Pressure bar

8
Proportional valve YCLT21

Current-flow curve
YCLT21B(low pressure version):

YCLT21B-Orifice Φ0.8mm YCLT21B-Orifice Φ1.0mm


Flow rate L/min

Flow rate L/min

Current mA Current mA

YCLT21B-Orifice Φ1.2mm YCLT21B-Orifice Φ1.6mm


Flow rate L/min

Flow rate L/min

Current mA Current mA

YCLT21B-Orifice Φ2.0mm YCLT21B-Orifice Φ2.4mm YCLT21B-Orifice Φ3.0mm


Flow rate L/min

Flow rate L/min

Flow rate L/min

Current mA Current mA Current mA

9
Proportional valve YCLT21

YCLT21G(High pressure version):

YCLT21G-Orifice Φ0.8mm YCLT21G-Orifice Φ1.0mm


Flow rate L/min

Current mA Flow rate L/min Current mA

YCLT21G-Orifice Φ1.2mm YCLT21G-Orifice Φ1.6mm


Flow rate L/min

Flow rate L/min

Current mA Current mA

YCLT21G-Orifice Φ2.0mm YCLT21G-Orifice Φ2.4mm YCLT21G-Orifice Φ3.0mm


Flow rate L/min

Flow rate L/min

Flow rate L/min

Current mA Current mA Current mA

Note *: There may be slight differences in product flow due to individual differences and different pipeline conditions. Please refer to the pressure
flow curve and select products that fully meet the flow requirements according to the requirements, leaving a standard with margin to select the model.

10
Proportional valve YCLT33

Characteristics:
• Special magnetic material heat treatment and special design of flat butterfly spring.
• Ultra small, light weight, low power consumption (Max.2W), high-performance
single power supply.
• Higher working pressure range, 10 millions cycles tests, performance is verified.
• Hysteresis (Min as low as 6%),excellent repetition (< 1%),
ideal for high precision flow control.

Typical Applications:
• Gas chromatographic analyzer
• Mass spectrum analyzer
• Oxygen generator/reservoir
• Ventilator
• Anesthesia delivery instrument
• Mass flow controller
• Pressure and flow control

Electrical parameters:
Coil Insulation: F
Electrical connection: 24 AWG L=500mm
Protection class: IP50
YCLT33(2F) YCLT33(3FB)
Voltage: 12VDC,24VDC
PWM frequency: PWM Frequency >4000Hz
*The appearance may change according to the specific situation of our
Hysteresis: Hysteresis 6%(min), ≤15%(full scale)
Flow regulation: Repetition≤1%;Sensitivity ≤0.1%

Technical data *customized service is on option

Orifice Max pressure Max flow Response


PART NO Model Port size Seal Body Coil Medium
(mm) (Bar) (L/min) time

0.08 10bar ——

0.15 10bar ——
G(NPT)1/8'' 0.25 10bar ——
nuetral
gas
G(NPT)1/4'' (Filter level:
0.6 10bar ——
0.08mm :
VITON BRASS 5μ);
YCLT33 2/2NC 1F(1 Flange) 0.8 10bar —— YJ2B 20ms
NBR SUS316L 0.2-0.6mm :
2F(2 Flange) 1.0 7bar —— 17μ);
0.8mm≥ :
3F(3 Flange) 1.2 6bar —— 40μ))

1.4 5bar ——

1.6 4bar ——

Working Temp.:-10℃~90℃ Ambient Temp.:-30℃~90℃

Coil Data

Type Resistance (Ω) Voltage (V) Max current(A) Maximum power(W)

YJ2B-DC12V-1W 144Ω DC12V 70 1W

YJ2B-DC24V-1W 576Ω DC24V 35 1W

YJ2B-DC12V-2W 72Ω DC12V 150 2W

YJ2B-DC24V-2W 288Ω DC24V 75 2W

11
Proportional valve YCLT33

Dimension

depth 8
orifice depth 10

depth 8
orifice depth 10

YCLT33(2F) YCLT33(3F)

thorough hole thorough hole

12
Proportional valve YCLT33

YCLT33(5F)

thorough hole

Pressure flow curve

YCLT33-(12V)-Orifice Φ0.8mm-0.15mm YCLT33-(12V)-Orifice Φ0.25mm-1.6mm


Flow rate L/min

Flow rate L/min

Pressure bar Pressure bar

Current-flow curve

YCLT33-Orifice Φ0.08mm YCLT33-Orifice Φ0.1mm


Flow rate L/min

Flow rate L/min

Current mA Current mA

13
Proportional valve YCLT33

YCLT33-Orifice Φ0.15mm YCLT33-Orifice Φ0.25mm


Flow rate L/min

Flow rate L/min


Current mA Current mA

YCLT33-Orifice Φ0.6mm YCLT33-Orifice Φ0.8mm YCLT33-Orifice Φ1.0mm


Flow rate L/min

Flow rate L/min

Flow rate L/min

Current mA Current mA Current mA

YCLT33-Orifice Φ1.2mm YCLT33-Orifice Φ1.4mm YCLT33-Orifice Φ1.6mm


Flow rate L/min

Flow rate L/min

Flow rate L/min

Current mA Current mA Current mA

Note *: There may be slight differences in product flow due to individual differences and different pipeline conditions. Please refer to the pressure
flow curve and select products that fully meet the flow requirements according to the requirements, leaving a standard with margin to select the model.

14
Proportional valve YCLT51

Characteristics:
• Flow of air and inert gas can be controlled proportionally
by changing the input electrical signal of the coil
• Maximum flow rate up to 200L/min, maximum pressure up to 60psi
• High repeatability and precision within its operating range
• Low power consumption, small size, reducing quality
generated during long-term use

Typical Applications:
• Ventilator
• Oxygen generator/reservoir
• Anesthesia delivery instrument
• Mass flow controller
• Pressure and flow contro

Electrical parameters:
Coil Insulation: F
Electrical connection: 24 AWG L=500mm
Protection class: IP50
*The appearance may change according to the specific situation of our
Voltage: 12VDC,24VDC
PWM frequency: PWM Frequency >4000Hz
Hysteresis: Hysteresis ≤15%(full scale)
Flow regulation: Repetition≤1%;Sensitivity ≤0.1%

Technical data *customized service is on option

Orifice Max pressure Max flow Response


PART NO Model Port size Seal Body Coil Medium
(mm) (Bar) (L/min) time

BRASS
YCLT51 —— F(Flange) 5.0 —— —— VITON YJ2B 20-40ms nuetral gas
SUS316L

Working Temp.:-10℃~90℃ Ambient Temp.:-30℃~90℃

Coil Data
Type Resistance (Ω) Voltage (V) Max current(A) Maximum power(W)

YJ2B -DC12V-2W 72Ω DC12V 150 2W

YJ2B -DC24V-2W 288Ω DC24V 75 2W

15
Proportional valve YCLT51

Dimension

thorough hole

Ori n g

Optional Mounting Valve Block (6061)

O-ring size(2 for each valve body) Cross head screw M3x20(2 for each valve body)

16
Proportional valve YCLT51

Pressure flow curve

YCLT51-Orifice Φ5.0mm

Flow rate L/min

Current mA

Current-flow curve

YCLT51
Flow rate L/min

Pressure bar

Note *: There may be slight differences in product flow due to individual differences and different pipeline conditions. Please refer to the pressure
flow curve and select products that fully meet the flow requirements according to the requirements, leaving a standard with margin to select the model.

17
Proportional valve YCLT71

Characteristics:
• Higherpressure,1 millioncycles test
Reliablequality,idealforhighprecisionflowcontrol
• Suitableforoxygenservice, performanceis verified
• Sensitivereaction,highprecision
• Compactdesign

Typical Applications:
• Ventilator
• Oxygen generator/reservoir
• Anesthesia delivery instrument
• Mass flow controller
• Pressure and flow contro

Electrical parameters: YCLT71(SS304) YCLT71(brass)

Coil Insulation: H
Electrical connection: 6.3*0.8 Plug *The appearance may change according to the specific situation of our

Protection class: IP65


Voltage: 12VDC,24VDC
PWM frequency: PWM Frequency 1200-2000Hz
Hysteresis: ≤15%(max)
Flow regulation: Repetition≤1%;Sensitivity≤ 0.1%

Technical data *customized service is on option

Orifice Max pressure Max flow Response


PART NO Model Port size Seal Body Coil Medium
(mm) (Bar) (L/min) time

1.2 6 82

1.6 5 120

2.0 4 148
YCLT71B
2.4 2.5 130
(low
pressure 3.0 1.75 130
version)
M5 4.0 1 117
G(NPT)1/8'' BARSS nuetral gas
1.2 12 108
VITON 20-40ms and
2/2NC 1F(1 Flange) SUS316L SC92B
NBR
1.6 10 190 AL liquid
2F(2 Flange)
3F(3 Flange) 2.0 8 290

YCLT71G 2.4 5 260


(High
3.0 3.5 260
pressure
version) 4.0 2 212

5.0 0.8 150

6.0 0.5 122

Working Temp.:-10℃~90℃ Ambient Temp.:-30℃~90℃

18
Proportional valve YCLT71

Coil Data

Type Resistance (Ω) Voltage (V) Max current(A) Maximum power(W)

SC92B-DC12V-13W 11Ω DC12V 0.8 13W

SC92B-DC24V-13W 44Ω DC24V 0.4 13W

Dimension

YCLT71B/G(G1/4)

depth 8

YCLT71B/G(G3/8)

YCLT71B/G(1F)

Oring Oring
× ×

19
Proportional valve YCLT71

Pressure flow curve

YCLT71-SB92B
Max flow rate VS pressure & orifice:

YCLT71G (High pressure version) YCLT71B(low pressure version):


Flow rate L/min

Flow rate L/min

Pressure bar Pressure bar

Current-flow curve

YCLT71B(low pressure version):

YCLT71B-Orifice Φ1.2mm YCLT71B-Orifice Φ1.6mm YCLT71B-Orifice Φ2.0mm


Flow rate L/min

Flow rate L/min

Flow rate L/min

Current mA Current mA Current mA

YCLT71B-Orifice Φ2.4mm YCLT71B-Orifice Φ3.0mm YCLT71B-Orifice Φ4.0mm


Flow rate L/min

Flow rate L/min

Flow rate L/min

Current mA Current mA Current mA

20
Proportional valve YCLT71

YCLT71G(High pressure version):

YCLT71G-Orifice Φ1.2mm YCLT71G-Orifice Φ1.6mm YCLT71G-Orifice Φ2.0mm


Flow rate L/min

Flow rate L/min

Flow rate L/min


Current mA Current mA Current mA

YCLT71G-Orifice Φ2.4mm YCLT71G-Orifice Φ3.0mm YCLT71G-Orifice Φ4.0mm


Flow rate L/min

Flow rate L/min

Flow rate L/min

Current mA Current mA Current mA

YCLT71G-Orifice Φ5.0mm YCLT71G-Orifice Φ6.0mm


Flow rate L/min

Flow rate L/min

Current mA Current mA

Note *: There may be slight differences in product flow due to individual differences and different pipeline conditions. Please refer to the pressure
flow curve and select products that fully meet the flow requirements according to the requirements, leaving a standard with margin to select the model.

21
Proportional valve YCLT81

Characteristics:
• Higherpressure,1 millioncycles test
Reliablequality,idealforhighprecisionflowcontrol
• Suitableforoxygenservice, performanceis verified
• Sensitivereaction,highprecision
• Compactdesign

Typical Applications:
• Mass flow controller
• Pressure and flow control
• Used for high demand regulation conditions

Electrical parameters:
Coil Insulation: H YCLT81(brass) YCLT81(SS304)
Electrical connection: 6.3*0.8 Plug
Protection class: IP65 *The appearance may change according to the specific situation of our

Voltage: 12VDC,24VDC
PWM frequency: PWM Frequency 600-800Hz
Hysteresis: ≤15%(max)
Flow regulation: Repetition≤1%;Sensitivity≤ 0.1%

Technical data *customized ser vice is on option

Orifice Max pressure Max flow Response


PART NO Model Port size Seal Body Coil Medium
(mm) (Bar) (L/min) time

2.0 25Bar 130

3.0 10Bar 550


G(NPT)3/8"
4.0 8Bar 620 nuetral gas
VITON BRASS
YCLT81 2/2NC SE71B 20-40ms and
NBR SUS316L
6.0 4Bar 550 liquid
G(NPT)3/8"
G(NPT)1/2" 8.0 2Bar 350

9.5 0.7Bar 200

Working Temp.:-10℃~90℃ Ambient Temp.:-30℃~90℃

Coil Data
Type Resistance (Ω) Voltage (V) Max current(A) Maximum power(W)

SE71B-DC24V-21W 27.5Ω DC24V 0.875 21W

22
Proportional valve YCLT81

Dimension

YCLT81(G3/8)

depth 8

depth 15

YCLT81(G1/2)

depth 8

depth 15

Pressure flow curve

YCLT81-SE71B
Max flow rate VS pressure & orifice:
YCLT81G
Flow rate L/min

Pressure bar

23
Proportional valve YCLT81

Current-flow curve

YCLT81G-Orifice Φ2mm YCLT81G-Orifice Φ3mm


Flow rate L/min

Flow rate L/min


Current mA Current mA

YCLT81G-Orifice Φ4mm YCLT81G-Orifice Φ6mm


Flow rate L/min

Flow rate L/min

Current mA Current mA

YCLT81G-Orifice Φ8mm YCLT81G-Orifice Φ9.5mm


Flow rate L/min

Flow rate L/min

Current mA Current mA

Note *: There may be slight differences in product flow due to individual differences and different pipeline conditions. Please refer to the pressure
flow curve and select products that fully meet the flow requirements according to the requirements, leaving a standard with margin to select the model.

24
Proportional PWM Controller

Working mechanism:
After the proportional valve controller is powered on, the controller continuously supplies
power and power off to the proportional valve at a certain frequency through the switching
device, thereby changing the current flowing through the proportional valve. By collecting
this current signal and changing the on/off frequency, the proportional valve constant
current drive function is achieved under voltage source power supply.condtions.

Method or application:
The controller uses standard signals from industrial sites for control (0-5V voltage, 0-10V
voltage, 0-20mA current, 4-20mA current, with one of the control signals selected) to
proportionally adjust the valve body current.

When using the controller, it is necessar y to connect the power line, ground wire, signal
wire, and connect the proportional valve wire to the proportional valve. After selecting
the appropriate voltage based on the proportional valve model and powering it on, the
adjustment of the proportional valve opening can be achieved by adjusting the current or
voltage of the signal line.

For example, a certain controller has an input of 0-5V and an output current of 1A. When
the control signal is detected to be 4V (80%), the controller executes the action. At this
time, the current flowing through the proportional valve is 0.8A (80%), and the flow rate
can be obtained by quer ying the proportional valve specification book .

Comparison:solenoid valve driver

Voltage Voltage back to 0,


increasing, solenoid valve
Current solenoid valve Current closed
start work

Time Time

Comparison:PWM Controller

Totally open

Flowrate increasing

Start open

25
Proportional PWM Controller

Differences:

Function Control method

There are only two states: on and off, which are manifested Powered on, solenoid valve working;
Solenoid valve externally as on and off states Power off, solenoid valve stop

Can continuously and proportionally adjust the opening, and Using continuously adjustable current
proportional valve can control the pressure and flow rate of the fluid. to control the opening of the
proportional valve

Due to conventional industrial equipment only providing a fixed voltage source (such as DC 24V) and not equipped with an adjustable
current source (such as 0-1A current source) Therefore, customers need to use a proportional valve controller or design their own
proportional valve control circuit when using proportional valves

Internal functional block diagram of the driver: Dimensions:

Wiring Instructions:

Wire define Signal difine


Determine voltage based
Red Power + Power + 12VDC/24VDC on proportional valve
Power supply ground/
Blue Power - Power - Ground analog ground

yellow signal line - signal line - Ground Optional, current control signal

White signal line + signal line + 0~5V/0~10V or 0~20mA/4~20mA

Connect the drive end


Black Proportional valve drive Proportional valve drive of the proportional valve
Connect the drive end
Black Proportional valve drive Proportional valve drive of the proportional valve

26