process measurement solutions 4
123
Mobrey
Magnetic Safety Switch Data sheet
SS1
Type 30800 MK.4
The Mobrey Magnetic Safety Operation resistant. A special key provided with
Switch is an interlock switch When the guard is in position the each switch permits access for
recommended for use where a actuating magnet must be located in installation and maintenance. The
sealed switch is required. the 'T' shaped recess of the fixed switch housing is proofed to allow
It is the responsibility of the assembly. The two 'T' shaped hosing with hot water as required by
user to carry out a suitable magnets will repel each other through food processing and other allied
risk assessment exercise of the wall of the fixed assembly to industries.
the total safety system in activate the SPDT changeover switch
accordance with BSEN954-1. with a snap action. Features
The retaining magnet in the switch ◗ Deters deliberate
Function body provides a return force to reverse interference
The Solartron Mobrey safety the changeover switch when the ◗ No springs
switch is designed primarily actuating magnet is withdrawn. ◗ No mechanical linkages
for fitting to safety guards or ◗ Magnetic transmission
access doors of electrically Advantages ◗ Dust proof
driven machines, wired in The Solartron Mobrey safety switch is ◗ Hose proof IP66
series with the stop/start operated by a special 'T' shaped ◗ Rugged
button circuit it will prevent magnet designed to deter deliberate ◗ Works in any position
the machinery being started interference.
unless the safety guard is in The magnetic transmission system Typical Applications
position, and it will break the eleminates the necessity for ◗ Bacon slicers
circuit if the guard is mechanical linkage between the ◗ Bean slicing machines
inadvertently opened while safety guard and the switch; this ◗ Bottle decrating and recrating
the machine is running. The feature is particularly advantageous machines
safety switch may also be where, for operating reasons the ◗ Bread slicers and wrappers
wired to an audible or visual guard has to be completely removed. ◗ Confectionery wrapping machines
alarm to indicate that a safety The switch contacts (S.P.D.T. ◗ Dough mixers and dividers
guard or access door is open. changeover) are moved in both ◗ Fish skinning machines
directions entirely by magnetic forces ◗ Food wrapping machines
and are not dependent upon springs ◗ Band saw change speed pulley
or toggle arrangements. access door
The switch cover is secured by special ◗ Foundary sand batch mixers
lockshield screws to make it tamper ◗ Guards on mills
◗ Bag and sack print machinery
◗ Gates and doors of rooms housing
dangerous machinery or
equipment
◗ Removable hoppers on filling
machines
◗ Cake and pie making machines
◗ Strapping machines
Complies with the requirements of
the applicable European directives
and regulations for a safety
component.
Construction
The Solartron Mobrey safety switch has
two main components :
Fixed Assembly
Comprises a die-cast aluminium housing
containing the second 'T' shaped magnet,
retaining magnet, switch contacts and
terminals. The retaining magnet ensures
that the contacts changeover with a
positive action.
Actuating Assembly
This assembly is attached to the movable
guard or door. The 'T' shaped permanent
magnet is spring mounted in a bracket
providing sufficient flexibility to allow for
slight misalignment with the 'T' recess in
the fixed assembly.
Specification Conduit entry U.L. listed auxiliary device. For
The Mobrey Magnetic Safety Switch is Model 30800: M20 x 1.5 to B.S. 4568 standard pilot duty B 300. Rating code
an interlock switch recommended for Model U30800: ½" - 14 NPT as in U.L. 508. Enclosure Type 4.
use where sealed switch is required. It Model C30800: ½" - 14 NPT
is the responsibility of the user to carry Operating Characterisitics
out a suitable risk assessment exercise Rating Ambient temp:
of the total safety system. Voltage Rating Rec. Maximum 60°C /140°F
Fuse Minimum 0°C / 32°F
Electrical 240 V A.C Mounting :
The single-pole double throw Non Inductive 480 V.A. 2A The switch will operate in any position.
changeover switch is of the air break 440V A.C. Weight: 0.91 kg / 2 lb
type employing fine silver-faced Non Inductive 440 V.A. 1A
contacts. 24 V D.C. 1 V.A. 1A Spare Parts
Description Part No.
Connections Rating : UL, CSA Actuating magnet
Terminals : A-AB closed with guard in 240 V A.C sub-assembly : 2 off SK48
place. In series with stop button. Non Inductive 360 V.A. 1A Cover gasket } SK49
Terminals : B-AB open with guard in Cover screw }
place. May be used to operate 'guard If used as a cut-out for inductive circuits Cover screw key SK96
open' warning light. giving peak current in acces of the above
the switch contacts should be connected
through a suitable relay.
Installation and Wiring IMPORTANT - PLEASE READ THOROUGHLY
Electrical : A fuse must be fitted in the supply line. Maximum rating as above.
Mechanical Single Switch Multi - Switch
Mounting : the switch will operate in
any position. Solartron Mobrey magnetic safety
switches may be wired in series,
A suitable cable gland must be fitted provided that any common 'guard
to maintain the IP rating. The moving open' indicator device is operated by
and fixed parts of the machinery the contacts of the motor starter or
guard must line up accurately at the contactor. Alternatively, each safety
point of closure in order to avoid switch should be wired to a
damage to the 'T' shaped actuating dedicated 'guard open' indicator.
magnet.
The dimension 0.157/0.147 (see We do not recommend the use of a
diagram above) is of particular common indicating device wired in
importance. parallel with the switches.
The switch contacts are not suitable
Actuating magnets attached to for direct starting of motors.
removable hoppers and guard should
be positioned so as not to carry the
weight of the hopper or guard when Maintenance : Regular maintenance and inspection is essential
removed.
Particular care should be taken on a ensure it is free from damage. If
It is not intended as a guide for badly regular basis to ensure that the the fixed assembly is damaged or
constructed or maintained guards. actuating magnet does not fail to locate worn, it should be completely
If a pneumatic or hydraulic interlock as a result of inadequate maintenance replaced and a new actuating
bolt is incorporated in the guard of the moving guard or a build-up of magnet sub-assembly also fitted.
mechanism, ensure the bolt can be dirt and debris from the process in the
correctly located before the A-AB 'T' shaped slot on the switch body, and
contacts close. that the magnet is regularly checked to
Solartron Mobrey Limited
Authorised distributor: Ward Industries Limited 1 24
3
Tel: +44 (0)1933 624963
a Roxboro Group Company
Г
Fax: +44 (0)1933 625458
Email: sales@[Link]
Web: [Link]
SS1
The right is reserved to amend details
given in this publication without notice Jan 2004