A B C D
COLUMN DETAIL
NOT DRAWN TO SCALE
WF CF WF CF
06 CF
06 L
WF WF WF
05 CF CF CF
05
W
WF WF
CF
04 CF WF WF
04 TYPICAL FOOTING PLAN DETAIL
NOT DRAWN TO SCALE
WF
WF
03 CF 03
NATURAL GRADE LINE
02 CF WF CF
02
4" thick CONCRE HOLLOW BLOCKS
DEPTH(D)
CF CF
01 01 Natural Grade Line
SPACED @ 400 MM ON
10 MM ø VERTICAL BARS
CENTER WITH 10 MM ø
THIRD LAYER OF
HORIZONTAL BAR IN EVERY
THICKNESS(T)
A C D
0.60
B CONCRETE HOLLOBLOCK
FOOTING LENGTH
FOUNDATION PLAN COLUMN FOOTING DETAIL SECTION
NOT DRAWN TO SCALE
3-12 MMø STRAIGHT BARS WITH
12 MM ø CROSS BAR SPACED AT
0.20 m 300 MM ON CENTER
0.40 m
FOOTING DETAILS
DESCRIPTION DEPTH(D) LENGTH(L) WIDTH(W) THICKNESS(T) SIZE OF DSB NO. OF DSB ALONG LENGTH NO. OF RSB ALONG WIDTH
F1(13PCS) 2.00 MTR 1.500 MTR 1.500 MTR 0.30 MTR 16 MM ø 10 PCS (150 MM SPACEING) 10 PCS (150 MM SPACEING) WALL FOOTING
COLUMN DETAILS
DETAIL SECTION
DESCRIPTION LENGTH(L) WIDTH(W) CLEAR COV. SIZE AND NO. OF DSB TO USED LATERAL TIES SIZE AND SPACING
C1(13PCS) SINGLE 10 MM ø DSB SPACED AT 4
SCALE: 1:100
0.35 MTR 0.25 MTR 0.04 MTR 6 PCS - 16MM ø
PCS @ 50 MM. 4PCS @ 100 MM,4PCS
@ 150 MM AND REST @ 200 MM 0.C,
JRMSU-COE SUBMITTED BY: YEAR: III SEAL: PROJECT: SUBMITTED TO: SHEET CONTENT: SET NO.: SHEET NO.:
BLOCK: B
ID NO.: 22-A-01216 PROPOSED 2-STOREY RESIDENTIAL BUILDING FOUNDATION PLAN, COLUMN & 5
A
NIÑA MICHELE P. COQUILLA
DATE: 04/25/25 ENGR. JOHN PAUL BATOCAEL WALL FOOTING SCHEDULE A
STUDENT PLATE NO: LOCATION: INSTRUCTOR