KOCETAL® K700
Polyacetal, General Purpose, Injection Molding, Low Viscosity
Properties Measurement condition Test Method Unit Typical value
Physical
Specific Gravity ASTM D792 - 1.41
Melt Flow Index 190 ℃, 2.16 kg ASTM D1238 g/10min 27.0
Shrinkage ASTM D955 % 1.8-2.2
Water Absorption 23 ℃, H2O, 24 hr ASTM D570 % 0.22
Mechanical
Tensile Strength at Yield (3.2mm) 50 mm/min ASTM D638 MPa 65
Nominal Strain at Break(3.2mm) 50 mm/min ASTM D638 % 35
Flexural Strength (3.2mm) 2 mm/min ASTM D790 MPa 97
Flexural Modulus (3.2mm) 2 mm/min ASTM D790 MPa 2,700
Izod Impact Strength (6.4mm) ASTM D256
(Notched) 23 ℃ J/m 55
-30 ℃ J/m -
Rockwell Hardness M scale ASTM D785 - 80
Thermal
Melting Point 20 ℃/min ASTM D3418 ℃ 167
Heat Deflection Temperature 1.8 MPa ASTM D648 ℃ 110
-5
Coefficient of linear expansion ASTM D696 × 10 cm/cm·℃ 13
Flammability (0.8mm) UL94 Class HB
Electrical
Dielectric Strength IEC 60243 kV/mm -
Volume Resistivity IEC 60093 Ω·cm -
Surface Resistivity IEC 60093 Ω/sq -
※ 1Mpa = 10.197162 Kgf/cm2, 1J/m = 0.10197 Kgf·cm/cm, ( Test specimen Thickness )
Updated: 2017-10-31
The values of each item in this document provide general information about the product and may be different from actual ones as reference dimensions for
customer's convenience of material selection. This information cannot be viewed as a Certificate of Analysis(COA) issued by the Company to customers, nor can it
be used as a basis for legal disputes such as lawsuits. The value of each item cannot be compared with the measurement result of other environment, equipment
and method because it is measured under the specific condition using the existing measurement equipment and external authorized agency equipment. The
characteristics described above are subject to change, and you are solely responsible for the determination and use of this product. In addition, these materials do
not apply when adding pigments and other additives to the product depending on the customer's purpose of use. The value of the shrinkage factor in the above
data is the value measured under the specific injection condition using our standard test piece and may be changed according to other test piece (product) and
condition. Therefore, it is the customer's responsibility to apply the correction by considering the required characteristics of the molded product, the mold design
condition,the product shape, the injection conditions, etc. Even if there is a difference in the shrinkage rate of the product in the mold manufactured by applying
this shrinkage ratio, we also assume no guarantee or liability.
Processing Guide (Injection Molding)
Drying Temperature(℃) 80 ~ 90
(Dehumidifying Dryer)
Drying Time(hr) 3~5
Processing Moisture
≤ 0.1
Contents(%)
Nozzle Front Middle Rear
Cylinder Temperature(℃)
180 ~ 200 180 ~ 200 170 ~ 190 160 ~ 180
Mold Temperature(℃) 60 ~ 80
Contact Us www.kolonplastics.com
Domestic Sales Domestic Sales(Yeongnam)
TEL : +82-2-3677-3621 / FAX :+82-2-3677-3556 TEL : +82-53-253-3792 / FAX : +82-53-253-3793
Global Sales R&D Division
TEL : +82-2-3677-3623 / FAX : 02-3677-3558 TEL : +82-54-421-1490 / FAX : +82-54-421-1449
Updated: 2017-10-31
The values of each item in this document provide general information about the product and may be different from actual ones as reference dimensions for
customer's convenience of material selection. This information cannot be viewed as a Certificate of Analysis(COA) issued by the Company to customers, nor can it
be used as a basis for legal disputes such as lawsuits. The value of each item cannot be compared with the measurement result of other environment, equipment
and method because it is measured under the specific condition using the existing measurement equipment and external authorized agency equipment. The
characteristics described above are subject to change, and you are solely responsible for the determination and use of this product. In addition, these materials do
not apply when adding pigments and other additives to the product depending on the customer's purpose of use. The value of the shrinkage factor in the above
data is the value measured under the specific injection condition using our standard test piece and may be changed according to other test piece (product) and
condition. Therefore, it is the customer's responsibility to apply the correction by considering the required characteristics of the molded product, the mold design
condition,the product shape, the injection conditions, etc. Even if there is a difference in the shrinkage rate of the product in the mold manufactured by applying
this shrinkage ratio, we also assume no guarantee or liability.