0% found this document useful (0 votes)
134 views1 page

25NB X Heavy

This document is a test certificate from APL Apollo Tubes Ltd. for steel tubes supplied to Ali Steel and Tubes Co. in Chennai, confirming compliance with IS 1239 (Part-I) 2004 in terms of chemical composition and mechanical properties. The certificate includes test results, dimensional characteristics, and confirms that the tubes have passed hydrostatic testing.

Uploaded by

Sarvanan Nb
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
134 views1 page

25NB X Heavy

This document is a test certificate from APL Apollo Tubes Ltd. for steel tubes supplied to Ali Steel and Tubes Co. in Chennai, confirming compliance with IS 1239 (Part-I) 2004 in terms of chemical composition and mechanical properties. The certificate includes test results, dimensional characteristics, and confirms that the tubes have passed hydrostatic testing.

Uploaded by

Sarvanan Nb
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd

ANNEXURE - 1 IS 1239( Part-1) Format No:F/QA-18

(Para 5 of the Scheme of Testing and Inspection) Rev No:02


APL APOLLO TUBES LTD.,UNIT-II,HOSUR Issue Date:01/09/14
CML/3323544
Manufacturer of : ERW GALVANIZED & BLACK STEEL TUBES & PIPES & HOLLOW SECTIONS
No. 332-338,Alur, Perandapalli-Po,Hosur - 635109 ( TN) INDIA , Email : hosur@[Link] Website : [Link]
TEST CERTIFICATE FOR STEEL TUBES
M/S…ALI STEEL AND TUBES CO - CHENNAI Test certificate No. APL/QA..2024-25/8251
Certificate Date…02.03.2025
Invoice no…2402021785
We certify that material described below fully confirms to IS 1239 (Part-I) 2004 Chemical composition & Mechanical properties of the products tested in accordance with the scheme of testing and inspection contained
in BIS certification mark license No. CM/L 3323544 as indicate against each order No. etc
(Please refer to IS 1239 (Part-I) 2004 for detail of specification requirements)
TEST RESULTS
CHEMICAL COMPOSITION MECHANICAL PROPERTIES GALVANIZING

Tensile % Elongation Zinc coating Uniformity 5


LENGTH Cast No./Heat Batch No./Coil Quantity Mn% (Size ≤25mm Bend test/
Order No. SIZE NB. MM CLASS/TYPE C% max- S% max- P% max- Strength Mpa weight g/m² Dip
( MM ) No. No. (Mt/Pcs.) max- Min-12%& size Flattening REMARKS
0.20 0.040 0.040 (min-320 (Min - (1Dip/
1.30 ≥ 150mm Min test
Mpa) 20%) 360g/m²) Minute)

25mmNB BLK - HEAVY /PE 6000 D993225 25010842 4.200 0.062 0.30 0.006 0.016 382 32% PASS NA NA

80mmNB BLK -MEDIUM /PE 6000 I100518 25202131 2.980 0.070 0.37 0.015 0.022 378 33% PASS NA NA

This is to certify that dimensional characteristic (outside diameter / thickness / straightness / length / end condition) and workmanship confirms the requirement of IS : 1239 (Part-I) 2004
This is to certified that each tube have been hydrostatically tested as a leak tightness test at a pressure of 5 MPa for 3 seconds and found satisfactory

SHIPPING ADVICE NO : SIGNATURE OF AUTHORISED SIGNATORY


WAGON NO : DESIGNATION -SENIOR MANAGER

TRUCK NO…TN54B7788 For APL APOLLO TUBES LTD

1. Abbreviations : [Link] - Screwed tubes & socketed,pipe threads conforming to IS:554-1999 ,2. PE- Plain square cut ends [Link] - Beveled ends, 4. SWS - Screwed with caps threads conforming to IS 554- 1999.