Schneider Electric ATV320U15M2C - Overhead Crane Parameter Settings
1. Motor Parameters (Motor Nameplate Settings)
UnS - Rated Motor Voltage: 400V (check motor plate)
nCr - Rated Motor Current: e.g., 4.5A
FrS - Rated Motor Frequency: 50Hz
nSP - Rated Motor Speed (RPM): e.g., 1440 RPM
tFr - Motor Thermal Protection: Enabled
2. Ramp Settings (Smooth Acceleration/Deceleration)
ACC - Acceleration Time: 2-5 sec
DEC - Deceleration Time: 2-5 sec
dEC2 - Second Deceleration Time: Optional (Emergency stop)
3. Brake Control Settings
bLF - Brake Control Function: Enabled
tbr - Brake Release Delay: 200-300 ms
tbd - Brake Application Delay: 200 ms
brS - Brake Sequence Management: Enabled if needed
4. Torque Control / Load Handling Settings
LAC - Auto-tuning: Run Auto-Tune
ttr - Torque Limit: 120-150%
nOL - Current Limit: Set as needed
5. Protections Settings (Safety Related)
OLT - Overload Timeout: 60 sec
tHt - Motor Overheat Alarm: Active
SCS - Safe Torque Off (STO): Connect to E-Stop
Schneider Electric ATV320U15M2C - Overhead Crane Parameter Settings
6. Application Specific (Advanced Settings)
APF - Application Profile: Profile 2 (Hoisting)
Anti-rollback: Enable if needed
Preset Speeds: Optional Multi-speed operation
Summary of Example Values (1.5kW Motor)
UnS: 400V
FrS: 50Hz
nCr: 4.5A
ACC: 3 sec
DEC: 3 sec
tbr: 250 ms
tbd: 200 ms
OLT: 60 sec
ttr: 150%