Lighting
Ecofit Ledtubes T8
Ecofit LEDtube 1200mm 16W 865 T8 I
Upgrade to efficient, long-lasting LED tubes with the Ecofit LED tubes. Ecofit LED
tubes are a fast and easy way to replace your old fluorescent tubes with modern,
efficient LED technology. Good quality of light with a natural lighting effect for use in
general lighting applications with low initial investment – an environmentally
friendly solution.
Product data
General Information Starting Time (Nom) 0.5 s
Cap-Base G13 [Medium Bi-Pin Fluorescent] Warm-up time to 60% light 0.5 s
Nominal lifetime 15,000 hour(s) Power Factor (Fraction) 0.5
Switching Cycle 50,000 Voltage (Nom) 220-240 V
Lighting Technology LED
Flux measurement reference Sphere Temperature
T-Case Maximum (Nom) 55 °C
Light Technical
Color Code 865 [CCT of 6500K] Controls and Dimming
Beam Angle (Nom) 240 degree(s) Dimmable No
Luminous Flux 1,600 lm
Color Designation Cool Daylight Mechanical and Housing
Correlated Color Temperature (Nom) 6500 K Bulb Material Glass
Luminous Efficacy (rated) (Nom) 100.00 lm/W Product Length 1,200 mm
Color Consistency <6 Bulb Shape T8
Color rendering index (CRI) 80 Net Weight (Piece) 0.215 kg
LLMF At End Of Nominal Lifetime (Nom) 70 %
Approval and Application
Operating and Electrical Energy Efficiency Class F
Line Frequency 50 to 60 Hz Energy Saving Product Yes
Input Frequency 50 to 60 Hz Approval Marks RoHS compliance CE marking KEMA Keur
Power Consumption 16 W certificate
Datasheet, 2024, November 6 data subject to change
Ecofit Ledtubes T8
Energy Consumption kWh/1000 h 16 kWh Order code 929001276122
EPREL Registration Number 491854 Material Nr. (12NC) 929001276122
EU RoHS compliant Yes Numerator - Quantity Per Pack 1
Ambient temperature range -20 °C to 45 °C EAN/UPC - Product/Case 8718699697020
Numerator - Packs per outer box 20
Product Data EAN/UPC - Case 8718699697037
Order product name Ecofit LEDtube 1200mm 16W 865 T8 I
Full product name Ecofit LEDtube 1200mm 16W 865 T8 I
Full product code 871869969702000
Dimensional drawing
Product D1 D2 A1 A2 A3
Ecofit LEDtube 1200mm 16W 865 T8 I 25.7 mm 28 mm 1,198 mm 1,205 mm 1,212 mm
Photometric data
150o 180o 150o General Uniform Lighting
1 x TLED 16W 6500K 240D 9290012761
200 1 x 1600 lm
Polaro intensityo diagramo Quantity estimation diagram UGR diagram
150 180 150 nr. of luminaires
16.0
200 hroom: 2.8 m hroom : 2.8 m
Reflectances: 0.70, 0.50, 0.20 22 Refl: 0.70 0.50 0.20
m
150
150 Maintenance factor: 1.0
60 25
Ceiling mounted
120o 120o Ceiling mounted
100
12.0 : viewed endwise
750 lx
50 45 Y : viewed crosswise
90o 90o
o
Y : Parallel to viewing dir.
120o
500 lx
120
50 30
8.0
19
60o 100 60o 300 lx 22
15
150
100
γ
200 4.0
0
(cd/1000lm) 0o 10 30 50 70 90 (m2) 4.0 8.0 12.0 m 16.0
X
0-180o 90-270o
Utilisation factor table Luminance Table
Light output ratio 1.00
Service upward 0.27 Reflectances (%) for ceiling, walls and working plane (CIE) Plane 0.0 15.0 30.0 45.0 60.0 75.0 90.0
Room Cone
Service downward 0.73 0.80 0.80 0.70 0.70 0.70 0.70 0.50 0.50 0.30 0.30 0.00
45.0 5495 5468 5447 5497 5709 6300 7671
Index 0.50 0.50 0.50 0.50 0.50 0.30 0.30 0.10 0.30 0.10 0.00
50.0 5311 5269 5221 5228 5376 5902 7379
50
CIE flux code 36 64 85 73 100 k 0.30 0.10 0.30 0.20 0.10 0.10 0.10 0.10 0.10 0.10 0.00
55.0 5150 5100 5022 4979 5040 5471 7030
60.0 5020 4962 4863 4765 4725 5031 6648
UGRcen (4Hx8H, 0.25H) 23 0.60 0.40 0.38 0.38 0.37 0.36 0.29 0.27 0.22 0.25 0.21 0.17
0.80 0.50 0.47 0.47 0.46 0.44 0.37 0.34 0.29 0.31 0.27 0.22 65.0 4911 4859 4728 4578 4434 4555 6150
1.00 0.58 0.53 0.54 0.53 0.51 0.43 0.40 0.35 0.36 0.32 0.27 70.0 4839 4789 4637 4441 4198 4074 5569
1.25 0.65 0.60 0.62 0.59 0.57 0.50 0.46 0.41 0.42 0.38 0.31 75.0 4821 4766 4602 4378 4019 3590 4802
1.50 0.72 0.65 0.67 0.65 0.62 0.55 0.50 0.45 0.46 0.42 0.35 80.0 4838 4777 4625 4362 3914 3130 3678
2.00 0.81 0.72 0.76 0.72 0.69 0.63 0.57 0.53 0.52 0.49 0.41
85.0 4876 4794 4658 4416 3899 2819 2103
2.50 0.87 0.77 0.82 0.78 0.74 0.68 0.62 0.58 0.57 0.54 0.46
90.0 4958 4875 4734 4500 4022 2845 1531
o o
3.00 0.92 0.81 0.86 0.81 0.77 0.72 0.66 0.62 0.60 0.57 0.49
2
4.00 0.98 0.85 0.92 0.86 0.81 0.77 0.71 0.67 0.65 0.62 0.53 (cd/m )
90 90
5.00 1.02 0.88 0.96 0.90 0.84 0.80 0.74 0.71 0.68 0.65 0.56
Ceiling mounted
2017-02-20
50
o
60o 100 60
150
200
(cd/1000lm) 0o
0-180o 90-270o
CalcuLuX Photometrics 4.5 Philips Lighting B.V. Page: 1/1
Light Distribution Diagram - Ecofit LEDtube 1200mm 16W 865 T8 I General uniform lighting - Ecofit LEDtube 1200mm 16W 865 T8 I
100
Intensity (%)
80
60
40
20
0
200 300 400 500 600 700 800
[nm]
Spectral Power Distribution Colour - Ecofit LEDtube 1200mm 16W 865 T8 I
Datasheet, 2024, November 6 2 data subject to change
Ecofit Ledtubes T8
Lifetime
100% 100
Lumen in %
95
98%
Lumen (%)
90
96% 85
80
94% 75
70
92% 0 5000 10000 15000 20000
45 50 55 60 65
Burning hours
Tc(°C)
Lumen Maintenance Diagram - Ecofit LEDtube 1200mm 16W 865 T8 I Lumen Maintenance Diagram - Ecofit LEDtube 1200mm 16W 865 T8 I
100 20000
Failure rate in %
80
15000
60 Life time (Hours)
B10L70
10000
40
B50L70
20 5000
0
0 5000 10000 15000 20000 25000 30000 0
50 55 60 65 70 75 80
Time (hours) Tc(°C)
LEDtube Ecofit 16W G13 840 24D ND LEDtube Ecofit 16W G13 840 24D ND
80
Failure rate in %
70
60 60
50
40 70
30
80
20
10
0
0 5000 10000 15000 20000
Time (hours)
LEDtube Ecofit 16W G13 840 24D ND
Datasheet, 2024, November 6 3 data subject to change
Ecofit Ledtubes T8
© 2024 Signify Holding All rights reserved. Signify does not give any representation or warranty as to the accuracy or
completeness of the information included herein and shall not be liable for any action in reliance thereon. The
information presented in this document is not intended as any commercial offer and does not form part of any
quotation or contract, unless otherwise agreed by Signify. Philips and the Philips Shield Emblem are registered [Link]
trademarks of Koninklijke Philips N.V. 2024, November 6 - data subject to change