SIPROTEC 7UM85
Generator protection
[Link]/siprotec
Description
The generator protection device SIPROTEC 7UM85 has
been designed specifically for the protection of generators
and power units. It contains all necessary main protection
functions and a large number of other protection and
monitoring functions. With its modular structure, flexibi-
lity, and the high-performance DIGSI 5 engineering tool,
SIPROTEC 7UM85 offers futureoriented solutions for pro-
tection, control, automation, monitoring, and Power Qua-
lity – Basic. For motors in explosive environments, the
SIPROTEC 7UM85 Generator Protection (width: 1/3 x 19”
SIPROTEC 7UM85 is also available with EN 60079-14 or to 2 x 19”)
VDE 0165, Part 1, ATEX (Verband der Elektrotechnik, El-
ektronik und Informationstechnik) certification In more complex power units (unit connection with
Main function Typical generator protection func-
generator circuit breaker and several auxiliary trans-
tions formers), additional SIPROTEC 5 devices are used, for
example, 7UT8x, 7SJ82, or 7SJ85 and 7SA, SD, SL86,
Inputs and outputs 5 predefined standard variants with at the upper-voltage side of the generator trans-
up to 16 current transformers and 8
former.
voltage transformers, 7 to 15 binary
inputs, 9 to 20 binary outputs 4 fast Using motor and generator protection functions (for
measuring transducer inputs (10 V or example, underexcitation protection) to protect syn-
20 mA)
chronous motors
Hardware flexibility Flexibility adjustable and expandable
I/O quantity structure within the
Detection and recording of power-quality data in the
scope of the modular SIPROTEC 5 mediumvoltage and subordinate low-voltage power
system; 1/6 expansion modules can system
be added, available with large or
small display, or without display Functions
DIGSI 5 permits all functions to be configured and com-
Housing width 1/3 × 19 inches to 2 × 19 inches
bined as required.
Applications Short-circuit protection (overcurrent protection, im-
Protection of generators in busbar connection of dif- pedance protection, differential protection)
ferent power, with directional stator ground-fault pro- Stator ground-fault protection (90% non-directional or
tection. directional, 100% with 3rd harmonic, real 100% pro-
Protection of generators in unit connection of differ- tection with 20-Hz voltage interference)
ent power (using the 100 % stator ground fault (20 Rotor ground-fault protection with different measur-
Hz) with larger generators) ing methods (ground current or ground-resistance
Protection of power units with one device per protec- monitoring)
tion group. In the generator transformer variant, the Underexcitation and overexcitation protection
7UM85 implements both generator and transformer
protection.
Efficient and modular
PQ-Basic: voltage unbalance; voltage changes: over-
High-precision reverse-power protection and universal
voltage, dip, interruption; TDD, THD and Harmonics
power protection
Extensive cybersecurity functionality, such as role-
Unbalanced-Load Protection
based access control (RBAC), protocolling security-re-
Overload protection and temperature supervision via lated events, signed firmware or authenticated net-
external RTD unit (with PT 100, for example) work access IEEE 802.1X
Universal overvoltage and undervoltage protection Simple, fast and secure access to the device via a stan-
with different measuring methods dard Web browser to display all information and diag-
nostic data, as well as vector diagrams, single-line and
Overfrequency and underfrequency protection, fre-
device display pages
quency change protection and monitoring of dwell
time in frequency bands as turbine protection (protec- Phasor Measurement Unit (PMU) for synchrophasor
tion against abnormal frequencies) measured values and IEEE C37.118 protocol
Protection functions for network decoupling (voltage Time synchronization using IEEE 1588
and frequency protection, directional reactive power
Capturing operational measured variables and protec-
undervoltage protection (QU protection) and vector-
tion function measured values for the evaluation of
jump protection)
the system, to support commissioning, and to analyze
Inadvertent energization protection to detect incorrect faults
activation of the circuit breaker
Frequency tracked protection functions over a wide
Circuit-breaker failure protection frequency range (10 Hz to 80 Hz) and the option to
assign the protection functions in a single device to
Circuit breaker reignition monitoring
different frequency tracking groups.
Single-channel parallel connection function (synchro- Powerful fault recording (buffer for a max. record time
nization) with adjustment commands for rotational of 80 sec. at 8 kHz or 320 sec. at 2 kHz)
speed (frequency) and voltage
Flexibly adjustable I/O quantity structure within the
Graphical logic editor to create powerful automation
scope of the SIPROTEC 5 modular system
functions in the device
Benefits
Integrated electrical Ethernet RJ45 for DIGSI 5 and IEC
61850 (reporting and GOOSE) Safe and reliable automation and control of your sys-
tems
Up to 4 pluggable communication modules, usable for
different and redundant protocols (IEC 61850-8-1, IEC Purposeful and easy handling of devices and software
61850-9-2 Client, IEC 60870-5-103, IEC 60870-5-104, thanks to a user-friendly design
Modbus TCP, DNP3 serial and TCP, PROFINET IO, PROFI- Cybersecurity in accordance with NERC CIP and BDEW
NET IO S2 redundancy) Whitepaper requirements
Virtual network sharing (IEEE 802.1Q - VLAN) Highest availability even under extreme environmen-
Reliable data transmission via PRP and HSR redun- tal conditions by standard coating of the populated
dancy protocols printed circuit boards
For all products using
security features of
Siemens For the U.S. published by OpenSSL, the
Siemens Industry Inc. following shall apply:
Smart Infrastructure
Electrification & 100 Technology Drive This product includes
software developed
Automation Alpharetta, GA 30005
by the OpenSSL Pro-
Mozartstraße 31 C United States ject for use in the
91052 Erlangen, OpenSSL Toolkit
Germany ([Link]),
cryptographic soft-
ware written by Eric
Customer Support: [Link]
Young
(eay@[Link])
© Siemens 2020. Subject to changes and errors. and software devel-
oped by Bodo
Moeller.