Fusion Building Systems has conducted a thermal modeling assessment of their light steel framing system, revealing significantly lower heat loss through junction details compared to generic thermal bridging data. The analysis confirmed that the linear thermal transmittance values were calculated correctly, leading to improved energy performance for buildings. The findings suggest that using accurate psi-values can enhance the assessment of building energy efficiency and sustainability certifications.

Uploaded by

john
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
20 views1 page

CaseStudy Fusion

Fusion Building Systems has conducted a thermal modeling assessment of their light steel framing system, revealing significantly lower heat loss through junction details compared to generic thermal bridging data. The analysis confirmed that the linear thermal transmittance values were calculated correctly, leading to improved energy performance for buildings. The findings suggest that using accurate psi-values can enhance the assessment of building energy efficiency and sustainability certifications.

Uploaded by

john
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd

www.steel-sci.

com

SCI ENGINEERING CONSULTANCY


THERMAL

9HULÀFDWLRQRIWKHUPDOPRGHOOLQJZRUN
7KH6&,DVVHVVHGDQGYHULÀHGWKHUPDOPRGHOOLQJZRUNFDUULHGRXWE\)XVLRQ%XLOGLQJ6\VWHPVIRUWKH
various junction details of its light steel framing system. Results from the thermal modelling showed
WKDWKHDWORVVWKURXJKWKHMXQFWLRQGHWDLOVLQWKH)XVLRQV\VWHPLVVLJQLÀFDQWO\ORZHUWKDQJHQHULF
Client: thermal bridging data for light steel construction suggests.

Fusion Building Systems was To assess the thermal performance of a building it is necessary to calculate the amount of heat
established in 2002 and is now loss through the building envelope which includes heat losses through thermal bridges that exist at
Europe’s leading provider of the various junction details as well as heat losses through the planar elements such as walls, roof,
pre-insulated Light Gauge windows and doors. Heat loss at a thermal bridge is measured by the linear thermal transmittance
Steel frame structures DOVRNQRZQDVWKHSVLYDOXH 

www.fusionbuild.com

Wall corner junction detail Wall corner thermal model

$VVHVVPHQWRIMXQFWLRQGHWDLOV
6&,XQGHUWRRNWKHDVVHVVPHQWRIGLIIHUHQWMXQFWLRQGHWDLOVIRUWKH)XVLRQV\VWHPDQGYHULÀHGWKDW
Fusion had followed appropriate procedures and methods and that the linear thermal transmittance
values and temperature factor values were calculated correctly.
7KH)XVLRQOLQHDUWKHUPDOWUDQVPLWWDQFHYDOXHVDUHVLJQLÀFDQWO\ORZHUWKDQWKRVHSXEOLVKHGIRU
JHQHULFOLJKWVWHHOFRQVWUXFWLRQ HJ$FFUHGLWHG&RQVWUXFWLRQ'HWDLOV +HQFHWKHWKHUPDOPRGHOOLQJ
DQGLWVYHULÀFDWLRQKDVEHHQH[WUHPHO\EHQHÀFLDOWR)XVLRQDVEXLOGLQJHQHUJ\SHUIRUPDQFHPRGHOV
can use accurate and improved psi-values. Thereby, producing better results when buildings are
DVVHVVHGIRU7KH&RGHIRU6XVWDLQDEOH+RPHV%XLOGLQJ(QHUJ\3HUIRUPDQFH&HUWLÀFDWHVDQG
Building Energy Ratings.

,QGHSHQGHQWFHUWLÀFDWLRQ DQDO\VLV
)XVLRQ%XLOGLQJ6\VWHP·V7HFKQLFDO'LUHFWRUFRPPHQWHG¶:HEHOLHYHWKDWWKHVDOHVDQGPDUNHWLQJ
SRWHQWLDORIRXUV\VWHPLVJUHDWO\LQFUHDVHGWKURXJKKDYLQJSURSHULQGHSHQGHQWFHUWLÀFDWLRQDQG
DQDO\VLVWKDWSURYHVLWGRHVZKDWLWLVGHVLJQHGWRGR:HXVH6&,IRUPDQ\DUHDVRIZRUNUHODWHGWR
the use of steel in construction, including technical support and guidance.’