Electrical Ref

The document outlines the electrical installation requirements for a building, adhering to the Philippine Electrical Code and local regulations. It specifies service voltage, materials, wiring types, conduit sizes, and installation practices, including grounding and mounting heights. All electrical work must be supervised by a registered electrical engineer or master electrician, and only one service entrance drop is permitted for the building.

Uploaded by

yconron070
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
38 views3 pages

Electrical Ref

The document outlines the electrical installation requirements for a building, adhering to the Philippine Electrical Code and local regulations. It specifies service voltage, materials, wiring types, conduit sizes, and installation practices, including grounding and mounting heights. All electrical work must be supervised by a registered electrical engineer or master electrician, and only one service entrance drop is permitted for the building.

Uploaded by

yconron070
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd

GENERAL NOTES a

1. ALL ELECTRICAL WORKS SHALL BE DONE 21800


IN ACCORDANCE WITH THE 4080 175 1225 925 435656 4283 2131 1120 2620 1150
PROVISION OF THE LATEST EDITION OF THE 3000 5279 1760 4790 2030 3790
PHILIPPINE ELECTRICAL CODE (PEC),
THE RULES AND REGULATIONS OF LOCAL
AND NATIONAL AUTHORITIES

2000

2000
CONCERNED WITH ENFORCEMENT OF RULES
AND REGULATIONS OF LOCAL
UTILITY COMPANY.

1152
2050

2050
7152
2. THE SERVICE VOLTAGE TO THE BUILDING SHALL
BE SINGLE PHASE, THREE WIRE

1025

1025
5200
230 VOLTS, 60 HERTZ SYSTEM. 2
PP1

975

820 975
3
3. THE INSTALLATION SHALL BE DONE AS FOLLOWS: PP1

b b

13000
a.) RIGID STEEL CONDUIT (RSC) ----- POWER

1130 670330 820

3301150
SERVICE ENTRANCE FEEDERS
b.) POLYVINYL CHLORIDE (PVC) -----
LIGHTING, POWER BRANCH CIRCUITS, AND

1130
2800
AUXILIARY LAYOUT.

1000

1000
1
PP1

4. ALL WIRES TO BE USED SHALL BE COPPER

900
4000
AND THERMOPLASTIC HEAT
INSULATED TYPE "THHN' UNLESS NOTED

2100
OTHERWISE SPECIFIED.

5. ALL MATERIALS TO BE USED SHALL BE BRAND


NEW AND OF THE APPROVED TYPE
FOR THE LOCATION AND PURPOSED INTENDED.
3000 4130
4079 175 1225
3850
925 435655
21800
2300
4285
1700
2130 1120
6821
2620 1150 a
21800
6. THE MINIMUM SIZE OF WIRE AND CONDUIT TO 4080 175 1225 925 435656 4283 2131 1120 2620 1150
555 2445 4279 3200 4500 3371 2300
BE USED SHALL BE 1.6 mm THHN
AND 15 mm dia. RESPECTIVELY.
a
7. WHENEVER NECESSARY PULL BOX SHALL BE

2000
PROVIDED EVEN NOT INDICATED IN
THE PLAN.

2050

2050
8. BRANCH CIRCUIT HOMERUNS SHALL NOT BE

3075

5200
COMBINED IN THE SAME RACEWAY
AND RACEWAY FOR AUXILIARY LINES SHALL NOT

1130 670330 820 975 1025

1025
CONTAINS POWER LINES.

5144

1130 670330645 1150


9. MOUNTING HEIGHTS SHALL BE AS FOLLOWAS:
b b

13000

13000
a.) 0.30m ABOVE FLOOR FINISH ----- 4
PP1
5
PP1

3925
C.O. OUTLET & AUX. OUTLET
b.) 1.40m ABOVE FLOOR FINISH -----
LIGHT CONTROL SWITCH
c.) 1.70m ABOVE FLOOR FINISH @ CENTER
PANELBOARDS
-----
L E GE ND:

1000
1000

1000
6
PP1
d.) ALL OTHER HEIGHTS -----
VERIFY TO THE ARCHITECT

3000
10.) ALL SERVICE ENTRANCE EQUIPMENTS SUCH
AS PANELBOARD SHALL BE
PROPERLY GROUNDED IN ACCORDANCE WITH THE
PROVISION OF THE PHILIPPINE ELECTRICAL CODE.
6820
3000 4130 2300 5550 5671
4080 175 1225 925 435655 4285 2130 1120 2620 1150
11.) THERE SHALL ONLY BE ONE SERVICE 21800
ENTRANCE DROP FOR THE BUILDING.

12.) ALL ELECTRICAL WORKS AND INSTALLATIONS


HEREIN SHALL BE DONE UNDER a
THE DIRECT SUPERVISION OF A DULY
REGISTERED ELECTRICAL ENGINEER
OR MASTER ELECTRICIAN.
DONE IN THE OFFICE OF: DESIGN BY: NOTE SHEET CONTENT SHEET NO.

WI L L I AM MARCOS
ALL DESIGNS, DRAWINGS, SPECIFICATIONS
& COPIES PREPARED AND FURNISHED BY
THE ARCHITECT IN CONNECTION WITH THE
T WO S T OR E Y R E S I DE NC E MR. & MRS. EDGARDO R. DATINGALING III 1
E3
PROJECT ARE INSTRUMENTS OF
3 D V I S U A L I Z A T I O N PROFESSIONAL SERVICE, THEY ARE THE

CONTACT NO:
0939 936 0596
EMAIL ADDRESS:
williammarcos007@[Link] PTR NO.: --
ARCHITECT

REG. NO.: --
PROPERTY OF THE ARCHITECT, WHETHER
THEY ARE EXECUTED OR NOT, THEY ARE
NOT TO BE REPRODUCED OR USE ON OTHER
BLK. 26 LOT 19 KAMAGONG ST CORNER MACOPA ST. GOLDRIDGE ESTATE PHASE II STA. CRUZ GUIGUINTO BULACAN 3015 O W N E R A S S H O W N
WORK EXCEPT IF WRITTEN AGREEMENT
FACEBOOK:[Link]/williammarcosdesign ISSUED AT: -- T.I.N.: -- WITH THE ARCHITECT.
ISSUED ON:-- -- RA 9266, ART 4, SEC 33 PROJECT TITLE OWNER
a a
21800 21800
4080 175 1225 925 435656 4283 2131 1120 2620 1150 4080 175 1225 925 435656 4283 2131 1120 2620 1150
3000 5279 1760 4790 2030 3790 555 2445 4279 3200 4500 3371 2300
2000

2000

2000
4
PP2
2050

2050

2050

2050
3075
3
PP2 6
PP2

7
5 PP2
PP2
1130 670330 820 975 1025

1025

1130 670330 820 975 1025

1025
5200

5144
7000

820 975

1000 1130 670330645 1150


1

b b b b
PP2
13000

13000

13000

13000
3301150

3925
1130
2800

5200
2
1000

1000

1000
1000
PP2

900
8 9
PP2 PP2
4000

3000
2100
6820
3000 4130 3850 2300 1700 6821 3000 4130 2300 5550 5671
4079 175 1225 925 435655 4285 2130 1120 2620 1150 4080 175 1225 925 435655 4285 2130 1120 2620 1150
21800 21800

a a

CONDUIT RUN FOR LIGHTING DISTRIBUTION IN ONE CIRCUIT CONDUIT ON BOX INSTALLATION DETAIL
( FOR EXPOSED OR INSIDE DROP - CEILING INSTALLATION )

DONE IN THE OFFICE OF: DESIGN BY: NOTE SHEET CONTENT SHEET NO.

WI L L I AM MARCOS
ALL DESIGNS, DRAWINGS, SPECIFICATIONS
& COPIES PREPARED AND FURNISHED BY
THE ARCHITECT IN CONNECTION WITH THE
T WO S T OR E Y R E S I DE NC E MR. & MRS. EDGARDO R. DATINGALING III 2
E3
PROJECT ARE INSTRUMENTS OF
3 D V I S U A L I Z A T I O N PROFESSIONAL SERVICE, THEY ARE THE

CONTACT NO:
0939 936 0596
EMAIL ADDRESS:
williammarcos007@[Link] PTR NO.: --
ARCHITECT

REG. NO.: --
PROPERTY OF THE ARCHITECT, WHETHER
THEY ARE EXECUTED OR NOT, THEY ARE
NOT TO BE REPRODUCED OR USE ON OTHER
BLK. 26 LOT 19 KAMAGONG ST CORNER MACOPA ST. GOLDRIDGE ESTATE PHASE II STA. CRUZ GUIGUINTO BULACAN 3015 O W N E R A S S H O W N
WORK EXCEPT IF WRITTEN AGREEMENT
FACEBOOK:[Link]/williammarcosdesign ISSUED AT: -- T.I.N.: -- WITH THE ARCHITECT.
ISSUED ON:-- -- RA 9266, ART 4, SEC 33 PROJECT TITLE OWNER
pp1 load schedule and computation
LOAD SCHEDULE : PP-1
circuit breaker rating outlet va per ckt ampere load
ckt
ac c.o.
no at af pole volt type 60w 32w 28w 14w 7w other load amp service wire ground wire conduit wire SERVICE ENTRANCE
180w LOCAL POWER SOURCE
1 20 50 2p 230 bo 4 18 80w ceiling lamp 713 3.10 2- 3.5 sqmm thhn 2.0 sqmm thhn 20 mm, dia. pvc 230 Vac, 60Hz, 2P , 3wire
2 20 50 2p 230 bo 4 16 3 80w ceiling lamp (2) 805 3.50 2- 3.5 sqmm thhn 2.0 sqmm thhn 20 mm, dia. pvc
3 20 50 2p 230 bo 3 26 680.8 2.96 2- 3.5 sqmm thhn 2.0 sqmm thhn 20 mm, dia. pvc
4 20 50 2p 230 bo 12 19 100w chandelier 1357 5.90 2- 3.5 sqmm thhn 2.0 sqmm thhn 20 mm, dia. pvc
5 20 50 2p 230 bo 48 839.5 3.65 2- 3.5 sqmm thhn 2.0 sqmm thhn 20 mm, dia. pvc
6 30 50 2p 230 bo 24 16 558.9 2.43 2- 3.5 sqmm thhn 2.0 sqmm thhn 20 mm, dia. pvc
7 20 50 2p 230 bo SPARE 1200 5.22 2- 3.5 sqmm thhn 2.0 sqmm thhn 20 mm, dia. pvc
M KW-HR METER

8 20 50 2p 230 bo SPARE 1200 5.22 2- 3.5 sqmm thhn 2.0 sqmm thhn 20 mm, dia. pvc
USE: 2-100 [Link] THHN
total 7354.2 31.98 1-30.0 Sq. mm THW
IN 65mm Ø RSC
1 TOTAL =5883.36VA @ 80% DF + 25% (3000VA) use: 2-22 sqm thhn & 1-14 sq. mm. thhn in 32
230V MCB
mm dia. rsc28.84A/100A)
1 TOTAL =28.84A PP1: 125at/100af, 2pcb, 230v 42 kaic
note: plug in type outlet 225 AT, 2P
230 V

USE: 2-100 [Link] THHN

pp2 load schedule and computation 1-30.0 Sq. mm THW


IN 65mm Ø RSC
225 AT, 2P
230V, 60HZ.
LOAD SCHEDULE: PP-2
circuit breaker rating outlet va per ampere load
ckt
ac c.o. ckt 125 AT, 2P 125 AT,2P
no at af pole volt type 60w 32w 28w 14w 7w amp service wire ground wire conduit wire
180w other load
1 20 50 2p 230 bo 5 2249.4 9.78 2- 3.5 sqmm thhn 2.0 sqmm thhn 20 mm, dia. pvc
2 20 50 2p 230 bo 7 3151 13.70 2- 3.5 sqmm thhn 2.0 sqmm thhn 20 mm, dia. pvc
3 20 50 2p 230 bo RANGE HOOD 3180 13.82 2- 3.5 sqmm thhn 2.0 sqmm thhn 20 mm, dia. pvc
30.0 SQ MM BCW
4 20 50 2p 230 bo 1500 WATTS REF 1800.9 7.83 2- 3.5 sqmm thhn 2.0 sqmm thhn 20 mm, dia. pvc GROUND LINE
5 30 50 2p 230 bo 1.5 HP ACU 2300 10.00 2- 3.5 sqmm thhn 2.0 sqmm thhn 20 mm, dia. pvc
6 30 50 2p 230 bo 1.5 HP ACU 2300 10.00 2- 3.5 sqmm thhn 2.0 sqmm thhn 20 mm, dia. pvc
7 30 50 2p 230 bo 1.5 HP ACU 2300 10.00 2- 3.5 sqmm thhn 2.0 sqmm thhn 20 mm, dia. pvc
8 30 50 2p 230 bo 1.5 HP ACU 2300 10.00 2- 3.5 sqmm thhn 2.0 sqmm thhn 20 mm, dia. pvc
125 AT, 2P
9 30 50 2p 230 bo 1.5 HP ACU 2300 10.00 2- 3.5 sqmm thhn 2.0 sqmm thhn 20 mm, dia. pvc 230 V, 60HZ
LIGHTING LIGHTING
10 20 50 2p 230 bo SPARE 1200 5.22 2- 3.5 sqmm thhn 2.0 sqmm thhn 20 mm, dia. pvc OUTLET 15 A 15 A OUTLET
11 20 50 2p 230 bo SPARE 1200 5.22 2- 3.5 sqmm thhn 2.0 sqmm thhn 20 mm, dia. pvc
C1 C2
total 26581.3 105.57 225 A
CONVENIENCE CONVENIENCE
LIGHTING LIGHTING
1 TOTAL =21265.04VA @ 80% DF + 25% (3000VA) use: 2-22 sqm thhn & 1-14 sq. mm. thhn in 32 mm OUTLET 15 A 15 A OUTLET
OUTLET OUTLET
dia. rsc95.71A/125A) 20 A 20 A
230V
C3 C4
1 TOTAL =95.71A PP2: 125at/150af, 2pcb, 230v 42 kaic C1 C2
note: plug in type outlet
LIGHTING LIGHTING RANGE HOOD REFRIGERATOR
OUTLET 15 A 15 A OUTLET OUTLET 40 A 40 A OUTLET

mcb load schedule and computation C5 C6


C3 C4

LIGHTING LIGHTING
load schedule : MDP OUTLET 15 A 15 A OUTLET
ACU
OUTLET 30 A 30 A
ACU
OUTLET

circuit breaker rating outlet C7 C8


ckt va per ckt ampere load C5 C6
ac c.o.
no at af pole volt type 60w 32w 28w 14w 7w amp service wire ground wire conduit wire
180w other load ACU ACU
1 125 150 2p 230 bo PP1 7354.2 31.98 2- 22 sqmm thhn 14.0 sqmm thhn 32 mm. dia. pvc 14.00 SQ MM BCW OUTLET 30 A 30 A OUTLET
GROUND LINE
2 125 150 2p 230 bo PP2 26581.3 105.57 2- 22 sqmm thhn 14.0 sqmm thhn 32 mm. dia. pvc C7 C8

total 33935.5 137.55 ACU


OUTLET 30 A 20 A SPARE

1 TOTAL =27148.40VA @ 80% DF + 25% (3000VA) use: 2-22 sqm thhn & 1-14 sq. mm. thhn in 32
230V mm dia. rsc121.30A
( /225a) C9 C10
pp1/pp2/pp3: 125at/150af, 2pcb, 230v 42
1 TOTAL =121.30 a kaic SPARE 20 A
note: plug in type outlet
C11

14.00 SQ MM BCW
GROUND LINE

DONE IN THE OFFICE OF: DESIGN BY: NOTE SHEET CONTENT SHEET NO.

WI L L I AM MARCOS
ALL DESIGNS, DRAWINGS, SPECIFICATIONS
& COPIES PREPARED AND FURNISHED BY
THE ARCHITECT IN CONNECTION WITH THE
T WO S T OR E Y R E S I DE NC E MR. & MRS. EDGARDO R. DATINGALING III 3
E3
PROJECT ARE INSTRUMENTS OF
3 D V I S U A L I Z A T I O N PROFESSIONAL SERVICE, THEY ARE THE

CONTACT NO:
0939 936 0596
EMAIL ADDRESS:
williammarcos007@[Link] PTR NO.: --
ARCHITECT

REG. NO.: --
PROPERTY OF THE ARCHITECT, WHETHER
THEY ARE EXECUTED OR NOT, THEY ARE
NOT TO BE REPRODUCED OR USE ON OTHER
BLK. 26 LOT 19 KAMAGONG ST CORNER MACOPA ST. GOLDRIDGE ESTATE PHASE II STA. CRUZ GUIGUINTO BULACAN 3015 O W N E R A S S H O W N
WORK EXCEPT IF WRITTEN AGREEMENT
FACEBOOK:[Link]/williammarcosdesign ISSUED AT: -- T.I.N.: -- WITH THE ARCHITECT.
ISSUED ON:-- -- RA 9266, ART 4, SEC 33 PROJECT TITLE OWNER

You might also like