XMO2pro
Oxygen Analyzer
Applications Benefits
• Inerting/blanketing liquid storage tanks • Accurate measurements from 0.01% to 100% O2 in gases
• Reactor feed gases • Compact design for cost-effective integration into the
process
• Centrifuge gases
• Explosion-proof and flameproof certified with weatherproof
• Catalyst regeneration
protection allows sensor to be remotely mounted at the
• Solvent recovery measurement point
• Landfill/Biogas processing • Unique, temperature-controlled dual-chamber cell design
• Sewage wastewater digester gas that is resistant to contamination and flow fluctuations
• Oxygen purity • Compact, rugged sensor design with no moving parts
provides long term reliability and trouble-free operation
• Reaction optimization
• High-contrast display, large magnetic buttons for easy
control under different environmental conditions
• Intuitive user interface enables easy and flexible use
• The MODBUS communication port provides extended
information with configurable options
• Minimal on-site/user-controllable maintenance
Thanks to the perfectly matched interaction between the Top performance and ease of use
paramagnetic oxygen property and temperature, the Safety
The compact, weatherproof, explosion-proof and flameproof
Integrity Level (SIL) certified XMO2pro is contamination
XMO2pro is specifically designed to be field installed
resistant, requires minimal maintenance and needs no
at the process measurement point, thus minimizing
consumables. This makes it the ultimate choice for highly
sampleconditioning requirements while ensuring the best
accurate oxygen measurements for widespread use in harsh
sample and the fastest possible response. The XMO2pro
environment industrial and oil & gas applications.
requires no consumables, has no moving parts, is insensitive
Advanced Oxygen Analyzer to vibration and therefore has excellent long-term reliability.
Designed for stability and longevity in hazardous area Choice of enclosures and ranges
locations, the XMO2pro provides high accuracy percent-level
The XMO2pro requires 24 VDC power and provides a 4 to 20
measurements and brings the user:
mA output signal with fully programmable zero and span
• Innovative sensor design for durable and highly accurate settings. The output is proportional to oxygen concentration
measurements and internally compensated for background gas and/or
• Intuitive operating interface allows for easy adoption and atmospheric pressure variations. The additional 4-20 mA
use output can be configured by the operator to provide an
alternative concentration range using the calibration of the
• Data transfer over the MODBUS digital communication port
first 4-20mA output. The weatherproof and explosion-proof
• Minimal maintenance and high level of reliability with SIL 2 options are available in a wide variety of measurement
by design ranges.
• Compact design for cost-effective Integration into the
Sample System
process
Sample systems deliver a clean, representative sample to
the XMO2pro at optimal temperatures, pressures and flow
6 7 rates. Panametrics offers sample systems for a wide variety of
Magnet
5 Wind generating
thermistor
applications.
Upper measurement
chamber
For assistance in designing your own sample system, please
consult our application engineering team.
4 8
Sample Gas
diffuses Wind receiving
thermistor
2
Lower flow-
through chamber
1 3
Sample 9 Sample
Inlet outlet
Induced gas flow
“magnetic wind”
Flow diagram of the XMO2pro measuring cell
Sample gas continually flows through the lower flow-through
chamber (1)(2)(3). This chamber acts as a pass-through
and protects the sensor from contamination. A portion of
the sample gas diffuses (4) into the upper chamber (5). The
oxygen molecules are drawn into the center by the magnet Automatic background gas compensation
(6) and leave across the heated matched thermistor pairs
An onboard microprocessor gives the XMO2pro the computing
(7)(8) creating a “magnetic wind” (9). These thermistor pairs
power to provide advanced online signal conditioning and
form part of a Wheatstone bridge, which generates a signal
MODBUS digital communications. Integrated signal-processing
proportional to the oxygen concentration in the sample gas.
algorithms provide improved linearity and accuracy, and
automatic compensation for background gas variations and/ or
atmospheric pressure effects. A fast response software routine
provides typical response time of less than 15 seconds.
Technical Specifications
4 1 Configuration and certification information
Functional and Physical
2 Mounting holes
3
5
3 Cable entries Warm-up time
6
4 Removable top cover 30 minutes
2
5 Removable front cover
1 7 Functional Safety
6 Multi-parameter display
IEC61508 SIL 2 (optional)
7 Magnetic keypad
8 8 Flame arrestors (gas inlet/outlet) and breather Analog output
Two 4 to 20 mA isolated, 550 Ω maximum load,
field-programmable
Performance
Digital output
Accuracy
Modbus RS232/RS485
• ±1% of span
Power
• ±2% of span for 0 to 1% range
24 VDC ±4 VDC, 2.5 A
Linearity
Ambient temperature range (Sample conditions)
±0.5% of span
• –20 to 40°C (–4 to 104°F), standard operating temperature
Repeatability
• –5 to 55°C (23 to 131°F), optional operating temperature
±0.2% of span
Operating pressure
Zero stability
• Close to atmospheric
±1% of span per month (±2% for 0 to 1% range)
• Max 2 barg (29 psig)
Span stability
Wetted sensor materials
±0.4% of span per month (±0.8% for 0 to 1% range)
• Standard: 316 stainless steel, glass and Viton® O-rings
Measurement Ranges
• Optional: Hastelloy® C276 and Chemraz® O-rings
• 0% to 1%
• Optional: 316 Stainless steel, glass and Chemraz® O-Rings
• 0% to 2%
Dimensions
• 0% to 5%
• Wp. (H x D x W): 228 x 178 x 142mm (9 x 7 x 6in)
• 0% to 10%
• Ex-proof (H x D x W): 252 x 178 x 142mm (10 x 7 x 6in)
• 0% to 21%
• 0% to 25% Weight
• 0% to 50%* • Aluminum version: 4.5kg / 9.9 lb
• 0% to 100%* • Stainless Steel version: 11.0 kg / 24.2 lb
• 80% to 100%* Environmental
• 90% to 100%* • IP66, Type 4X
Pressure effect IECEx compliance
• ±0.2% of span per mm Hg • Ex db IIC T6 Gb, Ex tb IIIC T78°C Db IP66
(without atmospheric pressure compensation) • -20°C < Tamb < +55°C
• Option available for atmospheric pressure compensation
European Union Compliance
Required sample flow rate • EMC Directive 2014/30/EU
• Nominal: 500 cc/min (1.0 SCFH) • ATEX 2014/34/EU: II 2 GD Ex db IIC T6 Gb, Ex tb IIIC T78°C Db
• Range: 50–1000 cc/min (0.1–2.0 SCFH) IP66
• Max: 1250 cc/min (2.7 SCFH)** • -20°C < Tamb < +55°C
Sample flow rate effect NEC/CEC
• Less than 1% of span for flow range of 50 to 1000 cc/min • Cl I, II, III Div 1/Div 2. Groups ABCDEFG, T6
(0.1 to 2.0SCFH) • -20°C < Tamb < +55°C
Response time, 90% step change
• Standard: 70 seconds
• EN50104: 45 seconds
• Fast-Response Option: 15 seconds
*Pressure compensation required
**Maximum permitted per Annex G of IEC60079-1
Aluminum Version
Stainless Steel Version
Ordering information
Model XMO2pro, Thermoparamagnetic Oxygen Analyzer
Enclosure Package
1 Aluminium enclosure, weatherproof, with display
2 Aluminium enclosure, explosion proof, with display
3 Stainless steel enclosure, weatherproof, with display
Installation Site Requirements
4 Stainless steel enclosure, explosion proof , with display
5 Aluminium enclosure, weatherproof, no display
6 Aluminium enclosure, explosion proof, no display
7 Stainless steel enclosure, weatherproof, no display
8 Stainless steel enclosure, explosion proof , no display
9 Without enclosure
Wetted Material
1 316 Stainless Steel, Viton O-Rings
2 Hastelloy, Chemraz O-Rings,
3 316 Stainless Steel, Chemraz O-Rings
Certification
1 Safe Area/General Purpose Area
2 USA/CAN Div 1, Zone 1/21
3 USA/CAN Div 2, Zone 2/22
4 ATEX/IECEx
Cell Temperature Set Point
0 Standard Operating Temperature
1 High Operating Temperature
Response Time
0 Standard Response
1 EN 50104 (45 seconds)
2 Fast Response
Oxygen Output Range
1 0 to 1%
2 0 to 2%
Analytical Performance, Software, and Specials
3 0 to 5%
4 0 to 10%
5 0 to 21%
6 0 to 25%
7 0 to 50%
8 0 to 100%
9 80 to 100%
10 90 to 100%
S OTHER
Compensation Signal
0 Background Gas Compensation, N2/CO2
1 Atmospheric Pressure Compensation, N2
2 Background Gas Compensation, Special Gas
3 Atmospheric Pressure Compensation, Special Range
4 Atmospheric Pressure & Standard Background Gas
5 Biogas CH4 and CO2
6 0-21% O2 in N2 and 14% CO2 in N2
S Special
Safety Level
SIL SIL2 By Design
STN Standard Industry Model
Special
0 No Special
S Special
XMO2PRO - 2 -1 -4 -0 -0 -6 -1 - SIL -0
Panametrics, a Baker Hughes business, provides solutions in the toughest
applications and environments for moisture, oxygen, liquid and gas flow
measurement.
Experts in flare management, Panametrics technology also reduces flare
emissions and optimizes performance.
With a reach that extends across the globe, Panametrics’ critical
measurement solutions and flare emissions management are enabling
customers to drive efficiency and achieve carbon reduction targets
across critical industries including: Oil & Gas; Energy; Healthcare; Water
and Wastewater; Chemical Processing; Food & Beverage and many others.
Join the conversation and follow us on LinkedIn
linkedin.com/company/panametricscompany
Copyright 2025 Baker Hughes Company. All rights reserved.
BHMADS05V10 (07/2025) panametrics.com