0% found this document useful (0 votes)
43 views4 pages

Itca& Hitachi Certif.

The document outlines air-conditioning design parameters for both summer and winter conditions, including temperature and pressure specifications. It details the proposed Hitachi VRF system, including outdoor and indoor unit specifications, features, and technical details. Additionally, it includes terms and conditions regarding the manufacturer, warranty, pricing, and delivery timelines.

Uploaded by

Kareem Al-Shaami
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
43 views4 pages

Itca& Hitachi Certif.

The document outlines air-conditioning design parameters for both summer and winter conditions, including temperature and pressure specifications. It details the proposed Hitachi VRF system, including outdoor and indoor unit specifications, features, and technical details. Additionally, it includes terms and conditions regarding the manufacturer, warranty, pricing, and delivery timelines.

Uploaded by

Kareem Al-Shaami
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd

ITCA

Air-conditioning design parameters


Air-conditioning design parameters
Summer atmospheric pressure 100846.2 Pa
Summer outdoor DB 48.0 ℃ 48 ℃
Summer Summer indoor DB 24.0 ℃ 24 ℃
Summer indoor WB 17.4 17.4 ℃
Winter Winter atmospheric pressure 100846.2 Pa
Winter outdoor DB 1 ℃
Winter
Winter Outdoor WB 0 ℃
Winter indoor DB 23 ℃
Altitude 0 m

TERMS AND CONDITIONS

1 AC Manufacturer: TICA / CHINA


2 Working Ambient Temperature: (T3) 56°C.
3 All Compressors are Mitsubishi DC inverter Made in Thailand .
4 Price: ex-warehouse in aghdad.
5 Validity: 30 days.
6 Delivery: Within (90-120) days.
7 Warranty: 1 years for installa on , 4 years for compressor in the event of a factory defect.
8 No accessories / options of the units other than what is clearly stated in our offer included.
Hitachi VRF system
1. PROPOSED SOLUTION SUMMARY:

Outdoor Units • Set free Model HNBCMQ


Indoor Unit • Air Handily Unit • DX Kit
Nominal Cooling Capacity (TR) MEKAR DX-AHU Units • AHU Units Load (19.5 Ton)
Nominal Cooling Capacity (TR) HITACHI VRF Dx-Condensing Units • VRF Condensing Units Load (22.3 Ton)
Controllers • Wired controller
VRF system Origin • Hitachi Factory in China

2. Proposed Systems
Description
1. HITACHI VRF SYSTEM HNBCMQ
HITACHI VRF system and outdoor units Features
• Outdoor units are supplied with R410A HITACHI inverter scroll compressor(s)
• Outdoor units have standard coating that can withstand 500 hours salt resistance test, Heavy
Anti corrosion coating that can withstand 1500 hours salt resistance test is available as option.

• Powerful propeller fan and DC inverter fan motor


• 60 Pa Maximum external static pressure for outdoor units
• Smart refrigerant temperature control
• Rotational and back up operation
• Continuous system operation in case of power failure of indoor unit

HITACHI Indoor units Features

DX Kit (DX-A1)

DX-KIT Air Handling Unit Integration to Hitachi VRF

FEATURES

(1) Wide range of capacity


(2) Flexible installation
(3) Flexible configuration

Wired Remote Controller (HCWA10NEGQ)


Features:
• Temperature Setting Rate: °C (0.5/1) °F (1)
• Indoor Fan Speed (*2) (*3) 3/4/6 Taps.
• Louver Direction (*2)
• Individual Louver Setting (*2)
• Automatic Reset Temperature (Cooling / Heating)
• Temperature Indication (*4)
• Filter Sign
• Filter Sign Reset
• Alarm Sign
• Sensor Condition Check
• Alarm History Display
• Operation Lock / Set
• Lower Limit for Cooling Operation
• Upper Limit for Heating Operation
• Built-in Timer (On / Off)
• Adjusting Date / Time Setting

3. Proposed system technical details


Unit Qty Rated Rated Power Max Air Depth Width Height weight
Cooling Heating Input Operatio Flow
Capacity Capacity n PI
KW KW KW KW m3/min mm mm mm kg
Indoor Unit
DXF-20.0A1 2 33.5 37.0 0.000 0
8
Outdoor
Unit
RAS- 1 33.5 37.5 8.27 8.27 190 782 958 1725 248
12HNBCMQ
RAS- 1 45 50.0 13.43 13.43 256 782 1218 1725 310
16HNBCMQ
AHU

1.1Air Handling Units General Features


› Maximum energy efficiency and indoor air quality

› Wide range of functions and options

› High quality components

› Innovative technology: Unique features and state of the art technology for short payback

› Operation efficiency and energy savings

› Outstanding reliability and performance

› Various applications are possible including air conditioning applications, industry-type process
cooling, and large-scale district heat source systems.

› Plug and play concept for easy installation and commissioning.

› Unique Daikin fresh air package available for connection of AHU to VRV or ERQ

Certifications
› Euro vent certified performances

› Exceeding 2018 Erp – ECODESIGN requirements

› Certified according to the Hygiene Directive VDI 6022 (Modular L and Professional ranges)

› Certified according to the Hygiene Directive DIN 1946 (Professional range)

› RLT certified performances

Unit S. A (m3/h) Supply ESP R. A Qty. Cooling Capacity (Kw)


(Pa) (m3/h)
AHU.01 (23MK-60-020026) 5000 300 4500 1 30.2
AHU.02 (23MK-60-018030) 6840 300 6160 1 39.9

Validity: 30 days.
Delivery: Within (90-130) days.