Structured Cabling System
Structured cabling system (SCS) is a set of
cabling and connectivity products that
integrates the voice, data, video, and various
management systems of a building
Contd..,
Building Space Cabling Sub System
Entrance Facility
Service Provider Cable
(OFC Room)
Equipment Room Main or Intermediate
(Server Room) Cross-Connect
Backbone Pathway
Backbone Cabling
(Vertical Shaft)
Telecommunications Room
Horizontal Cross-Connect
(Switch/Hub Room)
Horizontal Pathway
Horizontal Cabling
(Raceway)
Work Area Outlet
Components
Outlet for Data & Voice Desk Mounted
Cable (UTP & Fiber)
Patch Panel (UTP & Fiber)
Patch Cord(UTP & Fiber)
Rack
Wall Mounted
Outlets
RJ 45 Outlet will be used for DATA & Voice (VOIP)
RJ 11 Outlet will be used for Analogue Voice
Cables
HORIZONTAL
CAT 6 Cable will be used for DATA & Voice (VOIP)
2 Pair Cable will be used for Analogue Voice
Pair 1 = W/BL-BL
Pair 2 = W/O-O
Pair 3 = W/G-G
Pair 4 = W/BR-BR
CAT 6 Cable Color Coding as per TIA 568A
Contd..,
BACKBONE
Fiber Cable will be used for DATA & Voice (VOIP)
Multi Mode
Transmission
100 Mb 1 Gb 10 Gb 40 Gb 100 Gb
Standards
OM1 (62.5/125) 550 Mtrs 220 Mtrs 30Mtrs
Not supported
OM2 (50/125) 550 Mtrs 80 Mtrs
OM3 (50/125) 550 Mtrs 300 Mtrs 100 meters
OM4 (50/125) 550 Mtrs 1000 Mtrs 550 Mtrs 150 meters
Single Mode
Multi Pair Cable will be used for Analogue Voice
Patch Panel
COPPER
24 Port Patch Panel
48 Port Patch Panel
FIBER(SM/MM)
12 Port Patch Panel
24 Port Patch Panel
48 Port Patch Panel
Patch Cord
COPPER
CAT 6
2 Pair Cable
FIBER
Single Mode
Multi Mode
Design Needs
Customer's present and future requirements &
needs, in terms of
Performance
Density
Building blueprints (cabling spaces)
Site survey (if possible)
Knowledge of codes
Codes
Code Number Code Description
ANSI-TIA-EIA-568- Generic Telecommunication Cabling for
C.0 Customer Premises
Administration Standard for Commercial
ANSI-TIA-EIA-606-A
Telecommunication Infrastructure
Building Automation Systems Cabling Standard
ANSI-TIA-862
for Commercial Building
ANSI-TIA-942 Telecommunication Infrastructure Standard for
Data Center
Telecommunication Infrastructure Standard for
ANSI-TIA-1005 *
Industrial Premises
Telecommunications Distribution Methods
BICSI
Manual (TDMM)
NR Network Rail
Step 1:
To establish the No. of Data & Voice Points.
Step 2:
Calculate horizontal cabling & No.of Patch Panel
Step 3:
Calculate Backbone cabling & No.of Patch Panel
Step 4:
Calculate Rack Size
Data & VOIP Scheme
Data & VOIP Scheme
Copper Patch Cord Copper Patch Cord
Cat -5e/6/6A/7 Cat -5e/6/6A/7
4 Pair
Cat -5e/6/6A/7 Cable*
Fibre Patch Cord
Single / Multi Mode
Fibre Cable
Single / Multi Mode
* Cat Cable max 90 meters
Voice Cabling Scheme
?
?
?
?