TS16 Detector Configuration 170208 (IRay)

The document provides a comprehensive overview of the iRay detector configuration, including various sync solutions (AED, direct, hardware, software, hybrid) and dual-panel setups. It outlines the specifications for different iRay models, configuration steps for connecting detectors, and troubleshooting tips for maintaining connectivity. Additionally, it includes instructions for auto image recovery and Wi-Fi reconnection settings.

Uploaded by

Ervin John Yu Dy
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PPTX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
343 views19 pages

TS16 Detector Configuration 170208 (IRay)

The document provides a comprehensive overview of the iRay detector configuration, including various sync solutions (AED, direct, hardware, software, hybrid) and dual-panel setups. It outlines the specifications for different iRay models, configuration steps for connecting detectors, and troubleshooting tips for maintaining connectivity. Additionally, it includes instructions for auto image recovery and Wi-Fi reconnection settings.

Uploaded by

Ervin John Yu Dy
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PPTX, PDF, TXT or read online on Scribd

iRay

Detector
Configuration

E-COM Technology Limited


1F, Building 2, No.99 Kechuang 14 Street, BDA
Beijing 101111, P. R. China
TEL: (+86) 10 5975 5367
FAX: (+86) 10 5975 5360

March 31, 2025


Objectives
• iRay detector overview
• AED solution
• Direct sync solution
• Hardware sync solution
• Software sync solution
• Hybrid sync solution
• Dual-panel solutions
• Configurations
• Trouble shootings

2
Detector Overview
Venu 1717M(F) Mars 1717V Mars 1417V
Model
(40-150kV)
(14-bit A/D)

Pixel 139 μm 150 μm

Effective Pixel 3072 x 3072 2304 x 2800

Screen CsI GoS/CsI


Size (mm) 486 x 486 x 43 460 x 460 x 15 384 x 460 x 15
Weight 6.5 kg 4.8 kg 3.6 kg
Default IP [Link] [Link]
I/F Gigabit Ethernet 100M Ethernet, 2.4Ghz/5Ghz, 802.11 a/b/g/n
Sync Mode Sync box or Direct sync Software Sync & AED

3
AED Solution
• Mainly used for portable, mobile, or retrofit systems
• Any generator could be used for AED solution. To control Generator APRs by DROC, this
generator should be integrated by E-COM platform.
• The wireless router is not required if the Detector is configured as AP. For more about it,
please refer to iRay’s manual.

Generator

APR

Dongle

Wireless AP DROC Console


192.168.8.x [Link]
[Link]
iRay Mars Detectors

4
Direct Sync Solution
• In the “Direct” Sync mode, the Generator must be configured as direct exposure
without any sync.
• When DROC enters the Exam screen, it will let Detector enter the work mode.
• When the exposure switch
is pressed, Generator will
directly ask Detector to
open its exposure window.
RS-232
• The sync cable between the
Data
detector and the generator
should be wired by
Generator

Sync
professional electrical
engineers.
Ethernet
Sync (Mode 14)
DROC Console
iRay Venu 1717M(F)

5
Hardware Sync System
• Mainly used for fixed systems
• USB port or RS-232 port can be used for communication between E-COM Sync Box and
Computer.
• Ethernet cable between Detector and Computer is used for communication , e.g., image transfer

Data RS232 (Optional)

Sync Box USB


Sync 5V 500mA

1717M(F)
Ethernet
Generator
Hardware Sync DROC Console

6
Software Sync Solution
• Mainly used for portable or mobile systems.
• A generator supporting the software sync is required, for example, Sedecal or Mikasa. For
more information about wireless Mikasa Generator, please refer to PPT “Portable Solutions
[Mikasa]”.

[Link] Data & Sync

DROC Console c Wireless AP


n Mikasa E-COM
Sy 192.168.95.x Console Mate
a & Wi-Fi Generator 192.168.95.x
t
Da [Link]
(Optional)

192.168.95.x
(Coming soon …)
Iray Mars Detector

7
Hybrid Sync Solution (Coming soon …)
• Detector works in the software sync mode while Generator works in the hardware
sync mode.

RS-232 USB
APR Dongle
Generator
DVI/DP
RS-232
Sync USB

USB

[Link]

Wireless AP DROC LAN


192.168.8.x Console
[Link]
iRay Mars Detectors Hospital Network

8
Dual 1717M System (Coming soon …)
• Two Gigabit Ethernet adapter ports are required for DROC computer.

RS-232
Data
Generator

Sync RS-232 USB

Or USB Dongle
Sync Box

10.0.0.x/8
IRay 1717M
20.0.0.x/8

DROC Console

IRay 1717M

9
Venu + Mars System (Coming soon …)
• Two Gigabit Ethernet adapter ports are required for DROC computer.
• The Mars detector work in the AED/software mode while the Venu in the hardware sync
mode.

RS-232
Data
Venu 1717M Generator
[Link] USB
Sync RS-232
Or USB Dongle
Sync Box
10.0.0.x/8

[Link]

Wireless AP
[Link] 192.168.8.x DROC Console
iRay Mars Detectors

10
Configuration

11
Step 1. Connect Detector
• Connect iRay detector(s) by following iRay’s manual
• Configure IP address and related Wi-Fi if for Mars detectors
• Verify network connectivity by “ping”
• Test iRay detector with its service tool iDetector
• Calibrate iRay detector with iDetector

For more about the iRay detector service tool “iDetector”, please refer to
iRay’s manuals.

The iRay detector service tool “iDetector” has been packaged in “%DROC%\
IRAY\[Link]”

Quit the iDetector application whenever it is not in use.

Quit DROC and “PanelOprTest” before starting the iDetector application.

12
Step 2. DROC Configuration (V5.x)
• Go to “Config Tool > Hardware > Detector”

Specify an iRay detector


for your system

It is AED mode

Select it to connect the real


hardware. If not selected, DROC
will work in the demo mode

13
Step 3. Verify Connection (V5.x)
• In Config Tool > Hardware > Detector, click the button “Vefify connection” or run
“%DROC%\[Link]” application manually.

Quit “PanelOprTest” application whenever it is not in use.

Quit DROC and “iDetector” before starting the “PanelOprTest” application.

14
Trouble
E-COM

Shootings

15
Reconnect Wi-Fi
• When losing the communication with detector, i.e., goes out of AP range, or
replaces the battery, the Wi-Fi signal icon at the status bar of DROC bottom screen
will become grey.
• If this function is enabled, when the connection is lost,
an error message box will popup. When this physical connection is restored, this
Wi-Fi icon will become to green again, then close this error message window.

Lost Popup error Restore Close error


Connection Message Connection message

16
Configure Wi-Fi Reconnect
Version 5.x
• In the file “DROC\Conf\[Link]”, make sure
<Data key="Exam_DetectorCommunicationError_EnableExposure" value="NO" /
>
Version 6.x
• In the file “DROC\Client\[Link]”, make sure
<add key=“IsRequiredForDetectorReconnection" value=“True" />

Note: this function is enabled as default.

17
Auto Image Recovery (5.x)
• iRay detectos support auto image recovery during exam if the auto
reconnect is enabled.
• In the exam screen, if DROC lost communication with the panel after
pressed down the exposure switch:
– the acquired image by the panel cannot be transferred to DROC,
– an error message will popup, and
– the WiFi signal icon in the status bar will become grey.

• After the network physical link is restored, DROC can automatically


reconnect the panel and the Wi-Fi signal icon in the status bar will become
green. Then, click the Ok button on the message box now, the image in
the last exposure could be automatically retransmitted to DROC.

18
Q&A

19

You might also like