FIELD FRESH, LUDHIANA
Design of Intermediate Stiffeners:
Max Shear Force = 224 KN
Depth of the Web = 1250 mm
Thickness of the Web = 8 mm
Yield Strength of Steel = 345 N/mm2
1. UnStiffened Web :
For Unstiffened Web Minimum Thickness Required.
Case-1 :
t = dx Tva,cal
816
Tva,cal = V / (d x t) = 22.4 N/mm2
t = 7.25 mm
Case-2 :
t = d x Fy = 17.3 mm
1344
Case-3 :
t = d / 85 = 14.7 mm
UNSTIFFENED WEB IS [NOT APPLICABLE]
2. Stiffened Web :
Vertical Stiffener :
For Vertical Stiffened Web Minimum Thickness Required.
Case-1 :
t = d x Fy = 7.3 mm
3200
Case-2 :
t = d / 200 = 6.25 mm
VERTICAL STIFFENERS ARE [ONLY VERTICAL STIFFENER REQUIRED]
Horizontal Stiffener :
For Horizontal Stiffened Web Minimum Thickness Required.
Case-1 :
t = d x Fy = 5.8 mm
4000
Case-2 :
t = d / 250 = 5 mm
HORIZONTAL STIFFENERS ARE [NOT REQUIRED]
VERTICAL STIFFENER DESIGN :
Maximum Clear Spacing between Stiffeners = 180x Thickness of Web
= 1440 mm
Provide Vertical Stiffeners at = 1410 mm C/C 95 mm
d/t = 156.25 WEB
From Table 6.6B of IS:800-1984
c = 1.5d
Tva = 98 > 22.4 N/mm2 [SAFE] 1410 mm
- Minimum Thickness Required for Vertical Stiffener
t = V / (d x Tva) = 1.82 mm
8 mm
Provide a Flat Section as Vertical Stiffener of Thickness = t = 8 mm
- Maximum Out Stand of Vertical Stiffener = 12x t = 96 mm
Provide a Flat Section as Vertical Stiffener of Length = L = 95 mm
- Minimum Moment of Inertia Required = (1.5x d^3 x t^3) / c^2
= 8883.769 mm4
Moment of Inertia Provided = (t x L^3)/12 + t x L x ( L /2)^2
= 2286333 mm4 [SAFE]
Provide a Flat Section of Size 8 x 95 @ 1410 mm
Thickness Length Spacing
CONNECTIONS:
Shear Force = 125x t^2 / L = 84.21 N/mm
Let us Provide a 3 mm Thick intermitted Fillet Weld.
Stength of the Weld /mm = 226.8 N/mm [SAFE]
Length of the Weld = 10 x t = 80 mm
Spacing of Weld = 16 x t = 128 mm
Provide Intermitted Fillet Weld of 3 x 80 @ 128 mm
Thickness Length Spacing