Assumptions:
DEADLOAD
For slab:Thickness = 150 mm; Unit weight of concrete = 24KN/m
Descriptions ( Dormitory ) Uniform Load
Plumbing and electrical 0.50KPa
Ceramic or quarry tile (20mm) on 25mm mortar bed 1.10KPa
Ceiling 0.05
For stair:
Descriptions ( Dormitory ) Uniform Load
Handrails 0.05KPa
For wall:
Descriptions ( Dormitory ) Uniform Load
6” Concrete hollow block, full grout (exterior wall) 2.97KPa
4” Concrete hollow block, full grout (interior wall) 2.84KPa
Plaster each face 0.24KPa
Door (wooden door) 0.40KPa
Door (PVC) 0.30KPa
Window (analok) 0.38KPa
LIVELOAD:
Descriptions ( RESIDENTIAL ) Uniform Load
LL ROOM 2.0KPa
LL CR/RESTROOM 2.1KPa
LL HALLWAY/CORRIDOR 3.8KPa
LL ROOF DECK 1.9KPa
LL KITCHEN 1.9KPa
Computation
Computation of Deadload:
For slab:
𝑊𝑠 𝑊𝑠 𝑠
Ws= 3 ; Wl = 6 [3 – (𝐿) 2]
Wslab = unit weight of concrete (thickness) + Wtiles + Wplumbng and electrical
= (0.15m) (24KN/m3) + 1.10KPa + 0.50KPa
Wslab =5.20KPa
(5.20KPa)(1.50m)
Wslab1= = 2.60KN/m
3
(5.20KPa)(1.50m) 1.50m 2
Wslab2= [3 – ( ) ] = 3.74KN/m
6 4.5m
(5.20KPa)(2.30m)
Wslab3= = 3.99KN/m
3
(5.20KPa)(2.30m) 2.30m
Wslab4= [3 – (2.80m) 2] = 4.64KN/m
6
(5.2𝑜KPa)(1.50m)
Wslab5= = 2.60KN/m
3
(5.20KPa)(1.50m) 1.50m
Wslab6= [3 – (2.30m) 2] = 3.34KN/
6
(5.20KPa)(4.30m)
Wslab7= = 7.45KN/m
3
(5.20KPa)(2.0m)
Wslab8= = 3.47KN/m
3
(5.20KPa)(2.0m) 2.0m
Wslab9== [3 – (4.30m) 2] = 4.83KN/m
6
(5.20KPa)(2.0m) 2.0m 2
Wslab10= [3 – ( ) ] = 3.89KN/m
6 2.30m
(5.20KPa)(2.0m)
Wslab11= = 3.47KN/m
3
(5.20KPa)(1.0m) 1.0m
Wslab12= [3 – (3.0m) 2] = 2.5KN/m
6
(5.20KPa)(1.0m)
Wslab13= = 1.73KN/m
3
(5.20KPa)(2.0m) 2.0m
Wslab14= [3 – (2.8m) 2] =4.32KN/m
6
(5.20KPa)(2.0m)
Wslab15= = 3.47KN/m
3
Weight of Tank:
V= 2400L
Height= 2100mm
Diameter=1220mm
Thickness=200mm
ᵞs= 77.3 KN/m3
ᵞw=9.81 KN/m3
(2.4m3 )(9.81)= 23.544 KN
(0.05487m3)(77.3)= 4.242 KN
=27.786KN/4.3m
=6.462KN/m
FRAME A=FRAME G
For second floor:
Weightwall span 1= 3.45(2.9)
= 10.005 kN/m
For third floor:
Weightwall span 1= 3.45(2.8)
= 9.66 kN/m
For fourth floor:
Weightwall span 1= 3.45(2.7)
= 9.315 kN/m
For roofdeck:
Weightwall span 1=Weightwall span 4 =Weightwall span 5= Weightwall span 2=Weightwall span 3
= 3.45(0.6)
= 2.07 kN/m
FRAME B= FRAME C=FRAME D=FRAME E=FRAME F
For second floor:
Weightwall span 1= 3.32(2.9)
= 9.628 kN/m
For third floor:
Weightwall span 1= 3.32(2.8)
= 9.296 kN/m
For fourth floor:
Weightwall span 1= 3.32(2.7)
= 8.964 kN/m
For beam:
WB1= unit weight of concrete (AreaB1)
= (24KN/m) (0.50m x 0.30m)
WB1= 3.60KN/m
WB2= unit weight of concrete (AreaB2)
= (24KN/m) (0.40m x 0.20m)
WB2= 1.92KN/m
WB3= unit weight of concrete (AreaB2)
= (24KN/m) (0.40m x 0.15m)
WB2= 1.44KN/m
Wcantilever beam = unit weight of concrete (Areaintermedate beam)
= (24KN/m) (0.40m x 0.20m)
Wcantilever beam= 1.92KN/m
DEADLOAD PER FRAME:
FRAME A
FOR SECOND
WEIGHT FOR SPAN 1=W8 +WCB1 +WWALL
=15.395 Kn/m
WEIGHT FOR SPAN 2=W7 +WB1 +WWALL
=21.055 Kn/m
WEIGHT FOR SPAN 3
=21.055 Kn/m
WEIGHT FOR SPAN 4=W3 +WB1 +WWALL
=17.595 Kn/m
WEIGHT FOR SPAN 5=W1 +WCB1 +WWALL
=4.52 Kn/m
FOR Third
WEIGHT FOR SPAN 1=W8 +WCB1 +WWALL
=15.05 Kn/m
WEIGHT FOR SPAN 2=W7 +WB1 +WWALL
=20.71 Kn/m
WEIGHT FOR SPAN 3=20.71 Kn/m
WEIGHT FOR SPAN 4=W3 +WB1 +WWALL+WC3
=17.25 Kn/m
WEIGHT FOR SPAN 5=W1 +WCB1 +WWALL+WC1
=4.52 Kn/m
FOR fourth
WEIGHT FOR SPAN 1=W8 +WCB1 +WWALL
=14.705 Kn/m
WEIGHT FOR SPAN 2=W7 +WB1 +WWALL
=20.365 Kn/m
WEIGHT FOR SPAN 3=20.365 Kn/m
WEIGHT FOR SPAN 4=W3 +WB1 +WWALL
=16.905 Kn/m
WEIGHT FOR SPAN 5=W1 +WCB1 +WWALL
=4.52 Kn/m
FOR ROOFDECK
WEIGHT FOR SPAN 1=W8 +WCB1 +WWALL
=7.46 Kn/m
WEIGHT FOR SPAN 2=W7 +WB1 +WWALL
=13.12 Kn/m
WEIGHT FOR SPAN 3=13.12 Kn/m
WEIGHT FOR SPAN 4=W3 +WB1 +WWALL
=9.66 Kn/m
WEIGHT FOR SPAN 5=W1 +WCB1+WWALL
=6.59 Kn/m
FRAME B
FOR SECOND
WEIGHT FOR SPAN 1=W8 +WCB1 +WWALL
=15.018 Kn/m
WEIGHT FOR SPAN 2=W7 +WB1 +WWALL
=20.678 Kn/m
WEIGHT FOR SPAN 3=20.678 Kn/m
WEIGHT FOR SPAN 4=W3 +WB1 +WWALL
=17.218 Kn/m
WEIGHT FOR SPAN 5=W1 +WCB1 +WWALL
=4.52 Kn/m
FOR THIRD
WEIGHT FOR SPAN 1=W8 +WCB1 +WWALL
=14.686 Kn/m
WEIGHT FOR SPAN 2=W7 +WB1 +WWALL
=20.346 Kn/m
WEIGHT FOR SPAN 3=20.346 Kn/m
WEIGHT FOR SPAN 4=W3 +WB1 +WWALL
=16.886 Kn/m
WEIGHT FOR SPAN 5=W1 +WCB1 +WWALL
=4.52 Kn/m
FOR Fourth
WEIGHT FOR SPAN 1=W8 +WCB1 +WWALL
=14.354 Kn/m
WEIGHT FOR SPAN 2=W7 +WB1 +WWALL
=20.014 Kn/m
WEIGHT FOR SPAN 3=20.014 Kn/m
WEIGHT FOR SPAN 4=W3 +WB1 +WWALL
=16.554 Kn/m
WEIGHT FOR SPAN 5=W1 +WCB1 +WWALL
=4.52 Kn/m
FOR ROOFDECK
WEIGHT FOR SPAN 1=W8 +WCB1 +WWALL+WC8
=10.52Kn/m
WEIGHT FOR SPAN 2=W7 +WB1 +WWALL+WC7
=15.55 Kn/m
WEIGHT FOR SPAN 3=15.55 Kn/m
WEIGHT FOR SPAN 4=W3 +WB1 +WWALL+WC3
=10.55 Kn/m
WEIGHT FOR SPAN 5=W1 +WCB1+WC1
=5.39 Kn/m
FRAME C
FOR SECOND
WEIGHT FOR SPAN 1=W8 +WCB1 +WWALL
=15.018 Kn/m
WEIGHT FOR SPAN 2=W7 +WB1 +WWALL
=20.678 Kn/m
WEIGHT FOR SPAN 3=20.678 Kn/m
WEIGHT FOR SPAN 4=W3 +WB1 +WWALL
=17.218 Kn/m
WEIGHT FOR SPAN 5=W1 +WCB1 +WWALL
=4.52 Kn/m
FOR THIRD
WEIGHT FOR SPAN 1=W8 +WCB1 +WWALL
=14.686 Kn/m
WEIGHT FOR SPAN 2=W7 +WB1 +WWALL
=20.346 Kn/m
WEIGHT FOR SPAN 3=20.346 Kn/m
WEIGHT FOR SPAN 4=W3 +WB1 +WWALL
=16.886 Kn/m
WEIGHT FOR SPAN 5=W1 +WCB1 +WWALL
=4.52 Kn/m
FOR Fourth
WEIGHT FOR SPAN 1=W8 +WCB1 +WWALL
=14.354 Kn/m
WEIGHT FOR SPAN 2=W7 +WB1 +WWALL
=20.014 Kn/m
WEIGHT FOR SPAN 3=20.014 Kn/m
WEIGHT FOR SPAN 4=W3 +WB1 +WWALL
=16.554 Kn/m
WEIGHT FOR SPAN 5=W1 +WCB1 +WWALL
=4.52 Kn/m
FOR ROOFDECK
WEIGHT FOR SPAN 1=W8 +WCB1 +WWALL+WC8
=10.52Kn/m
WEIGHT FOR SPAN 2=W7 +WB1 +WWALL+WC7
=15.55 Kn/m
WEIGHT FOR SPAN 3=15.55 Kn/m
WEIGHT FOR SPAN 4=W3 +WB1 +WWALL+WC3
=10.55 Kn/m
WEIGHT FOR SPAN 5=W1 +WCB1+WC1
=5.39 Kn/m
FRAME D
FOR SECOND
WEIGHT FOR SPAN 1=W8 +WCB1 +WWALL
=15.018 Kn/m
WEIGHT FOR SPAN 2=W7 +WB1 +WWALL
=20.678 Kn/m
WEIGHT FOR SPAN 3=20.678 Kn/m
WEIGHT FOR SPAN 4=W3 +WB1 +WWALL
=17.218 Kn/m
WEIGHT FOR SPAN 5=W1 +WCB1 +WWALL
=4.52 Kn/m
FOR THIRD
WEIGHT FOR SPAN 1=W8 +WCB1 +WWALL
=14.686 Kn/m
WEIGHT FOR SPAN 2=W7 +WB1 +WWALL
=20.346 Kn/m
WEIGHT FOR SPAN 3=20.346 Kn/m
WEIGHT FOR SPAN 4=W3 +WB1 +WWALL
=16.886 Kn/m
WEIGHT FOR SPAN 5=W1 +WCB1 +WWALL
=4.52 Kn/m
FOR Fourth
WEIGHT FOR SPAN 1=W8 +WCB1 +WWALL
=14.354 Kn/m
WEIGHT FOR SPAN 2=W7 +WB1 +WWALL
=20.014 Kn/m
WEIGHT FOR SPAN 3=20.014 Kn/m
WEIGHT FOR SPAN 4=W3 +WB1 +WWALL
=16.554 Kn/m
WEIGHT FOR SPAN 5=W1 +WCB1 +WWALL
=4.52 Kn/m
FOR ROOFDECK
WEIGHT FOR SPAN 1=W8 +WCB1 +WWALL+WC8
=10.52Kn/m
WEIGHT FOR SPAN 2=W7 +WB1 +WWALL+WC7
=15.55 Kn/m
WEIGHT FOR SPAN 3=15.55 Kn/m
WEIGHT FOR SPAN 4=W3 +WB1 +WWALL+WC3
=10.55 Kn/m
WEIGHT FOR SPAN 5=W1 +WCB1+WC1
=5.39 Kn/m
FRAME E
FOR SECOND
WEIGHT FOR SPAN 1=W8 +WCB1 +WWALL
=15.018 Kn/m
WEIGHT FOR SPAN 2=W7 +WB1 +WWALL
=20.678 Kn/m
WEIGHT FOR SPAN 3=20.678 Kn/m
WEIGHT FOR SPAN 4=W3 +WB1 +WWALL
=17.218 Kn/m
WEIGHT FOR SPAN 5=W1 +WCB1 +WWALL
=4.52 Kn/m
FOR THIRD
WEIGHT FOR SPAN 1=W8 +WCB1 +WWALL
=14.686 Kn/m
WEIGHT FOR SPAN 2=W7 +WB1 +WWALL
=20.346 Kn/m
WEIGHT FOR SPAN 3=20.346 Kn/m
WEIGHT FOR SPAN 4=W3 +WB1 +WWALL
=16.886 Kn/m
WEIGHT FOR SPAN 5=W1 +WCB1 +WWALL
=4.52 Kn/m
FOR Fourth
WEIGHT FOR SPAN 1=W8 +WCB1 +WWALL
=14.354 Kn/m
WEIGHT FOR SPAN 2=W7 +WB1 +WWALL
=20.014 Kn/m
WEIGHT FOR SPAN 3=20.014 Kn/m
WEIGHT FOR SPAN 4=W3 +WB1 +WWALL
=16.554 Kn/m
WEIGHT FOR SPAN 5=W1 +WCB1 +WWALL
=4.52 Kn/m
FOR ROOFDECK
WEIGHT FOR SPAN 1=W8 +WCB1 +WWALL+WC8
=10.52Kn/m
WEIGHT FOR SPAN 2=W7 +WB1 +WWALL+WC7
=15.55 Kn/m
WEIGHT FOR SPAN 3=15.55 Kn/m
WEIGHT FOR SPAN 4=W3 +WB1 +WWALL+WC3
=10.55 Kn/m
WEIGHT FOR SPAN 5=W1 +WCB1+WC1
=5.39 Kn/m
FRAME F
FOR SECOND
WEIGHT FOR SPAN 1=W8 +WCB1 +WWALL
=15.018 Kn/m
WEIGHT FOR SPAN 2=W7 +WB1 +WWALL
=20.678 Kn/m
WEIGHT FOR SPAN 3=20.678 Kn/m
WEIGHT FOR SPAN 4=W3 +WB1 +WWALL
=17.218 Kn/m
WEIGHT FOR SPAN 5=W1 +WCB1 +WWALL
=4.52 Kn/m
FOR THIRD
WEIGHT FOR SPAN 1=W8 +WCB1 +WWALL
=14.686 Kn/m
WEIGHT FOR SPAN 2=W7 +WB1 +WWALL
=20.346 Kn/m
WEIGHT FOR SPAN 3=20.346 Kn/m
WEIGHT FOR SPAN 4=W3 +WB1 +WWALL
=16.886 Kn/m
WEIGHT FOR SPAN 5=W1 +WCB1 +WWALL
=4.52 Kn/m
FOR Fourth
WEIGHT FOR SPAN 1=W8 +WCB1 +WWALL
=14.354 Kn/m
WEIGHT FOR SPAN 2=W7 +WB1 +WWALL
=20.014 Kn/m
WEIGHT FOR SPAN 3=20.014 Kn/m
WEIGHT FOR SPAN 4=W3 +WB1 +WWALL
=16.554 Kn/m
WEIGHT FOR SPAN 5=W1 +WCB1 +WWALL
=4.52 Kn/m
FOR ROOFDECK
WEIGHT FOR SPAN 1=W8 +WCB1 +WWALL+WC8
=10.52Kn/m
WEIGHT FOR SPAN 2=W7 +WB1 +WWALL+WC7
=15.55 Kn/m
WEIGHT FOR SPAN 3=15.55 Kn/m
WEIGHT FOR SPAN 4=W3 +WB1 +WWALL+WC3
=10.55 Kn/m
WEIGHT FOR SPAN 5=W1 +WCB1+WC1
=5.39 Kn/m
FRAME G
FOR SECOND
WEIGHT FOR SPAN 1=W8 +WCB1 +WWALL
=15.395 Kn/m
WEIGHT FOR SPAN 2=W7 +WB1 +WWALL
=21.055 Kn/m
WEIGHT FOR SPAN 3=21.055 Kn/m
WEIGHT FOR SPAN 4=W3 +WB1 +WWALL
=17.595 Kn/m
WEIGHT FOR SPAN 5=W1 +WCB1 +WWALL
=4.52 Kn/m
FOR Third
WEIGHT FOR SPAN 1=W8 +WCB1 +WWALL
=15.05 Kn/m
WEIGHT FOR SPAN 2=W7 +WB1 +WWALL
=20.71 Kn/m
WEIGHT FOR SPAN 3=20.71 Kn/m
WEIGHT FOR SPAN 4=W3 +WB1 +WWALL+WC3
=17.25 Kn/m
WEIGHT FOR SPAN 5=W1 +WCB1 +WWALL+WC1
=4.52 Kn/m
FOR fourth
WEIGHT FOR SPAN 1=W8 +WCB1 +WWALL
=14.705 Kn/m
WEIGHT FOR SPAN 2=W7 +WB1 +WWALL
=20.365 Kn/m
WEIGHT FOR SPAN 3=20.365 Kn/m
WEIGHT FOR SPAN 4=W3 +WB1 +WWALL
=16.905 Kn/m
WEIGHT FOR SPAN 5=W1 +WCB1 +WWALL
=4.52 Kn/m
FOR ROOFDECK
WEIGHT FOR SPAN 1=W8 +WCB1 +WWALL
=7.46 Kn/m
WEIGHT FOR SPAN 2=W7 +WB1 +WWALL
WEIGHT FOR SPAN 3=13.12 Kn/m
WEIGHT FOR SPAN 4=W3 +WB1 +WWALL
=9.66 Kn/m
WEIGHT FOR SPAN 5=W1 +WCB1+WWALL
=6.59 Kn/m
LlVELOAD:
Descriptions ( Dormitory ) Uniform Load
LL ROOM 2.0KPa
LL CR/RESTROOM 2.1KPa
LL HALLWAY/CORRIDOR 3.8KPa
LL ROOF DECK 1.9KPa
LL KITCHEN 1.9KPa
(5.20KPa)(1.50m)
WLL1= = 2.60KN/m
3
(5.20KPa)(1.50m) 1.50m
WLL2= [3 – ( 4.5m ) 2] = 3.74KN/m
6
(1.9KPa)(2.30m)
WLL3= = 1.46KN/m
3
(1.9KPa)(2.30m) 2.30m
WLL4= [3 – (2.80m) 2] = 1.69KN/m
6
(2.1KPa)(1.50m)
WLL5= = 1.05KN/m
3
(2.1KPa)(1.50m) 1.50m
WLL6= [3 – (2.30m) 2] = 1.35KN/
6
(2.0KPa)(4.30m)
WLL7= = 2.87KN/m
3
(3.80KPa)(2.0m)
WLL8= = 2.53KN/m
3
(3.80KPa)(2.0m) 2.0m
WLL9== [3 – (4.30m) 2] = 3.53KN/m
6
(3.80KPa)(2.0m) 2.0m 2
WLL10= [3 – ( ) ] = 2.84KN/m
6 2.30m
(3.80KPa)(2.0m)
WLL11= = 2.53KN/m
3
(3.80KPa)(1.0m) 1.0m
WLL12= [3 – (3.0m) 2] = 1.83KN/m
6
(3.80KPa)(1.0m)
WLL13= = 1.27KN/m
3
(3.80KPa)(2.0m) 2.0m
WLL14= [3 – (2.8m) 2] =3.15KN/m
6
(3.80KPa)(2.0m)
WLL15= = 2.53KN/m
3
LIVELOAD PER FRAME:
FRAME A
FOR SECOND, THIRD FOURTH FLOOR
WEIGHT FOR SPAN 1=W LL8
=2.53Kn/m
WEIGHT FOR SPAN 2=W LL7
=2.87Kn/m
WEIGHT FOR SPAN 3=2.87Kn/m
WEIGHT FOR SPAN 4=W LL3
=1.46Kn/m
WEIGHT FOR SPAN 5=W LL1
=2.6Kn/m
FRAME B
FOR SECOND, THIRD FOURTH FLOOR
WEIGHT FOR SPAN 1=W LL8
=2.53Kn/m
WEIGHT FOR SPAN 2=W LL7
=2.87Kn/m
WEIGHT FOR SPAN 3=2.87Kn/m
WEIGHT FOR SPAN 4=W LL3
=1.35Kn/m
WEIGHT FOR SPAN 5=W LL1
=2.6Kn/m
FRAME C
FOR SECOND, THIRD FOURTH FLOOR
WEIGHT FOR SPAN 1=W LL
=2.53Kn/m
WEIGHT FOR SPAN 2=W LL7
=2.87Kn/m
WEIGHT FOR SPAN 3=2.87Kn/m
WEIGHT FOR SPAN 4=W LL3
=1.46Kn/m
WEIGHT FOR SPAN 5=W LL1
=2.6Kn/m
FRAME D
FOR SECOND, THIRD FOURTH FLOOR
WEIGHT FOR SPAN 2=W LL7
=2.87Kn/m
WEIGHT FOR SPAN 3= 2.87Kn/m
WEIGHT FOR SPAN 4=W LL6
=1.35Kn/m
WEIGHT FOR SPAN 5=W LL1
=2.6Kn/m
FRAME E
FOR SECOND, THIRD FOURTH FLOOR
WEIGHT FOR SPAN 1=W LL15
=2.53Kn/m
WEIGHT FOR SPAN 2=W LL7
=2.87Kn/m
WEIGHT FOR SPAN 3=2.87Kn/m
WEIGHT FOR SPAN 4=W LL3
=1.46Kn/m
WEIGHT FOR SPAN 5=W1
= 2.6Kn/m
SEISMIC LOAD:
FRAME A=FRAME G
Weightgroundfloor=11.48(4.3)(2)+8.74(2.3)
=118.83
Weightsecondfloor=Weightthirddfloor
=4.58(1.5)+16.89(2.3)+19.58(4.3)(2)+14.68(2)+33.91+12.36
=289.74 kN
Weightroofdeck=9.04(1.5)+10.52(2.3)(2)+15.55(4.3)(2)+13.64+25.61
=234.93 kN
Computation of seismic force applied:
Type of building: RCMRF
Zone 4
Weightgroundfloor=118.83 kN
Weightsecondfloor=289.74 kN
Weightthirddfloor=289.74kN
Weightroofdeck=234.93 kN
∑W=933.24 kN
hground floor= 3.20m
h2nd floor = 3.00m
h3rd floor = 3.00m
∑h=9.20 m
Distance from seismic source A 50km
Table 208-1 (Importance factor, I) 1.00
Table 208-2 (Soil profile type) SD
Table 208-3 (Seismic zone factor, z) 0.40
Table 208-5 (Near source factor, Na) 1.00
Table 208-6 (Near source factor, Nv) 1.00
Table 208-11 (Numerical coefficient, R) 8.5
Table 208-7 (Seismic coefficient, Ca) 0.44Na
Table 208-8 (Seismic coefficient, Cv) 0.64Nv
Total seismic dead loads, W KN
Total height of the building, h 9.20m
T= 0.0731(∑h) ¾
= 0.0731(9.2) ¾
T= 0.3862sec
Ca= 0.44Na
= 0.44(1.00)
Ca= 0.44
Cv= 0.64Nv
= 0.64(1.00)
Cv= 0.64
CvIW 0.64(1)(933.24KN)
V= = = 181.95KN
RT 8.5(0.3862sec)
V not less than:
Vminimum= 0.11(CaIW)
= 0.11(0.44) (1) (933.24KN)
Vminimum= 45.17KN
For zone 4:
0.8z(Nv)Iw
Vminimum=
R
0.8(0.40)(1.0)(1.0)(933.24KN)
=
8.5
Vminimum = 35.13KN
V not exceed:
2.5CaIW
Vmaximum=
R
2.5(0.44)(1)(933.24KN)
=
8.5
Vmaximum = 120.77KN
Vminimum< V <Vmaximum
45.17KN < 181.95KN < 120.77KN
35.13KN < 181.95KN < 120.77KN
Therefore:
UseVmaximum = 120.77KN
When: T < 0.70s, Ft= 0
0.3862< 0.70s
Therefore: Ft= 0
(Vmaximum−Ft)Wxhx
Fx= ∑n
𝑖−1 Wihi
Level Wx, KN hx, m Wxhx, KN-m Fx,KN
Roof 234.93 9.2 2161.356 53.4353
3rd 289.74 6.2 1796.388 44.4122
2nd 289.74 3.2 927.168 22.9224
Ground 118.83 0 0 0
∑= 4884.912 ∑= 120.77
VERTICAL IRREGULARITY:
WEIGHT(MASS) IRREGULARITY
1.5 WGROUNDFLOOR > WSECONDFLOOR
1.5(118.83kN) > 289.74 kN
178.25 kN> 289.74 kN
178.25 kN< 289.74 kN
Therefore: There is no weight irregularity exist.
FRAME B=FRAME F
Weight for each floor
Weightgroundfloor=16.36(4.3)(2)+12.25(2.3)
=168.87 kN
Weightsecondfloor=4.58(1.5)+15.93(2.3)+20.13(4.3)(2)+12.65(2)+33.91+12.36+33.91
=290.49kN
Weightthirddfloor=290.49
Weightroofdeck=4.58(1.5)+12.07(2.3)(2)+16.27(4.3)(2)+9.82(2)+14.28+25.61
=234.08kN
Computation of seismic force applied:
Type of building: RCMRF
Zone 4
Weightgroundfloor=168.87
Weightsecondfloor=290.49 kN
Weightthirddfloor=290.49kN
Weightthirddfloor=234.08 kN
∑W=983.93kN
∑h=9.20 m
Distance from seismic source A 50km
Table 208-1 (Importance factor, I) 1.00
Table 208-2 (Soil profile type) SD
Table 208-3 (Seismic zone factor, z) 0.40
Table 208-5 (Near source factor, Na) 1.00
Table 208-6 (Near source factor, Nv) 1.00
Table 208-11 (Numerical coefficient, R) 8.5
Table 208-7 (Seismic coefficient, Ca) 0.44Na
Table 208-8 (Seismic coefficient, Cv) 0.64Nv
Total seismic dead loads, W KN
Total height of the building, h 9.20m
T= 0.0731(∑h) ¾
= 0.0731(9.2) ¾
T= 0.3862sec
Ca= 0.44Na
= 0.44(1.00)
Ca= 0.44
Cv= 0.64Nv
= 0.64(1.00)
Cv= 0.64
CvIW 0.64(1)(983.93KN)
V= = = 191.83KN
RT 8.5(0.3862sec)
V not less than:
Vminimum= 0.11(CaIW)
= 0.11(0.44) (1) (983.93KN)
Vminimum= 47.62KN
For zone 4:
0.8z(Nv)Iw
Vminimum=
R
0.8(0.40)(1.0)(1)(983.93KN)
=
8.5
Vminimum = 37.04KN
V not exceed:
2.5CaIW
Vmaximum=
R
2.5(0.44)(1)(983.93KN)
=
8.5
Vmaximum = 127.93KN
Vminimum< V <Vmaximum
47.62KN < 191.83KN < 127.93KN
37.04KN < 191.83KN < 127.93KN
Therefore: useVmaximum = 127.93KN
When: T < 0.70s, Ft= 0
0.3862< 0.70s
Therefore: Ft= 0
(Vmaximum−Ft)Wxhx
Fx= ∑n
𝑖−1 Wihi
Level Wx, KN hx, m Wxhx, KN-m Fx,KN
Roof 234.08 9.2 2153.536 56.4074
3rd 290.49 6.2 1801.038 47.1745
2nd 290.49 3.2 929.568 24.3481
Ground 168.87 0 0 0
∑= 4884.142 ∑= 127.93
VERTICAL IRREGULARITY:
WEIGHT(MASS) IRREGULARITY
1.5 WGROUNDFLOOR > WSECONDFLOOR
1.5(168.87kN) > 290.49kN
253.31kN> 290.49kN
253.31kN< 290.49kN
Therefore: There is no weight irregularity exist.
FRAME C
Weight for each floor
Weightgroundfloor=16.35(4.3)(2)+12.25(2.3)
=168.79 kN
Weightsecondfloor= 4.58(1.5)+15.13(2.3)+20.13(4.3)(2)+5.47(2)+23.11+12.36
=261.2 kN
Weightthirdfloor=261.2kN
Weightroofdeck=5.17(1.5)+12.73(2.3)+16.27(4.3)(2)+6.06(2)+13.63+25.61
=217.36kN
Computation of seismic force applied:
Type of building: RCMRF
Zone 4
Weightgroundfloor=168.79 kN
Weightsecondfloor=261.2 kN
Weightthirddfloor=261.2 kN
Weightroofdeck= 217.46 kN
∑W=908.65 kN
∑h=9.20 m
Distance from seismic source A 50km
Table 208-1 (Importance factor, I) 1.00
Table 208-2 (Soil profile type) SD
Table 208-3 (Seismic zone factor, z) 0.40
Table 208-5 (Near source factor, Na) 1.00
Table 208-6 (Near source factor, Nv) 1.00
Table 208-11 (Numerical coefficient, R) 8.5
Table 208-7 (Seismic coefficient, Ca) 0.44Na
Table 208-8 (Seismic coefficient, Cv) 0.64Nv
Total seismic dead loads, W KN
Total height of the building, h 9.20m
T= 0.0731(9.2) ¾
T= 0.3862sec
Ca= 0.44Na
= 0.44(1.00)
Ca= 0.44
Cv= 0.64Nv
= 0.64(1.00)
Cv= 0.64
CvIW 0.64(1)(908.65KN)
V= = = 177.15KN
RT 8.5(0.3862sec)
V not less than:
Vminimum= 0.11(CaIW)
= 0.11(0.44) (1) (908.65KN)
Vminimum= 43.98KN
For zone 4:
0.8z(Nv)Iw
Vminimum=
R
0.8(0.40)(1.0)(1)(908.65KN)
=
8.5
Vminimum = 34.21KN
V not exceed:
2.5CaIW
Vmaximum=
R
2.5(0.44)(1)(908.65KN)
=
8.5
Vmaximum = 117.59KN
Vminimum< V <Vmaximum
43.98KN < 177.15KN < 117.59KN
34.21KN < 177.15KN < 117.59KN
Therefore:
useVmaximum = 117.59KN
When: T < 0.70s, Ft= 0
0.3862s< 0.70s
Therefore: Ft= 0
(Vmaximum−Ft)Wxhx
Fx= ∑n
𝑖−1 Wihi
Level Wx, KN hx, m Wxhx, KN-m Fx,KN
Roof 217.46 9.2 2000.632 52.796
3rd 261.2 6.2 1619.44 42.7365
2nd 261.2 3.2 835.84 22.0575
Ground 168.79 0 0 0
∑= 4455.912 ∑= 117.59
VERTICAL IRREGULARITY:
WEIGHT(MASS) IRREGULARITY
1.5 WGROUNDFLOOR > WSECONDFLOOR
1.5(168.79kN) > 261.2kN
253.19kN> 261.2kN
253.19kN< 261.2kN
Therefore: There is no weight irregularity exist
FRAME D
Weight for each floor
Weightgroundfloor=16.35(4.3)(2)+12.25(2.3)
=168.79 kN
Weightsecondfloor= 4.58(1.5)+15.93(2.3)+20.13(4.3)(2)+13.64
=230.27 kN
Weightsecondfloor=230.27 kN
Weightroofdeck=5.17(1.5)+(2.3)(12.73)+16.27(4.3)(2)+5.47(2)+13.04+11.19
=212.13 kN
Computation of seismic force applied:
Type of building: RCMRF
Zone 4
Weightgroundfloor=168.79 kN
Weightsecondfloor= 230.27 kN
Weightthirddfloor=230.27 kN
Weightroofdeck=212.13k
∑W=841.46 kN
∑h=9.20 m
Distance from seismic source A 50km
Table 208-1 (Importance factor, I) 1.00
Table 208-2 (Soil profile type) SD
Table 208-3 (Seismic zone factor, z) 0.40
Table 208-5 (Near source factor, Na) 1.00
Table 208-6 (Near source factor, Nv) 1.00
Table 208-11 (Numerical coefficient, R) 8.5
Table 208-7 (Seismic coefficient, Ca) 0.44Na
Table 208-8 (Seismic coefficient, Cv) 0.64Nv
Total seismic dead loads, W KN
Total height of the building, h 9.20m
T= 0.0731(∑h) ¾
= 0.0731(9.2) ¾
T= 0.3862sec
Ca= 0.44Na
= 0.44(1.00)
Ca= 0.44
Cv= 0.64Nv
= 0.64(1.00)
Cv= 0.64
CvIW 0.64(1)(841.46KN)
V= = =164.05KN
RT 8.5(0.3862sec)
V not less than:
Vminimum= 0.11(CaIW)
= 0.11(0.44) (1) (841..46KN)
Vminimum= 40.73 KN
For zone 4:
0.8z(Nv)Iw
Vminimum=
R
0.8(0.40)(1.0)(1)(841.46KN)
=
8.5
Vminimum = 31.68 KN
V not exceed:
2.5CaIW
Vmaximum=
R
2.5(0.44)(1)(841.46KN)
=
8.5
Vmaximum = 108.89 KN
Vminimum< V <Vmaximum
47.4524KN < 164.05KN < 108.89KN
27.4020KN < 164.05KN < 108.89KN
Therefore:
useVmaximum = 108.89 KN
When: T < 0.70s, Ft= 0
0.3862s< 0.70s
Therefore: Ft= 0
(Vmaximum−Ft)Wxhx
Fx= ∑n
𝑖−1 Wihi
Level Wx, KN hx, m Wxhx, KN-m Fx,KN
Roof 212.13 9.2 1951.596 51.6284
3rd 230.27 6.2 1427.674 37.7683
2nd 230.27 3.2 736.864 19.4933
Ground 168.79 0 0 0
∑= 4116.134 ∑= 108.89
VERTICAL IRREGULARITY:
WEIGHT(MASS) IRREGULARITY
1.5 WGROUNDFLOOR > WSECONDFLOOR
1.5(168.79kN) > 230.27kN
253.19kN> 230.27kN
253.19kN< 230.27kN
Therefore: There is no weight irregularity exist
FRAME E
Weight for each floor
Weightgroundfloor=16.35(4.3)(2)+12.25(2.3)
=168.79
Weightsecondfloor=4.58(1.5)+16.89(2.3)+20.13(4.3)(2)+5.47(2)+23.97+12.36
=265.42kN
Weightthirdfloor=265.42kN
Weightroofdeck=5.17(1.5)+12.73(2.3)(2)+16.27(4.3)(2)+5.47(2)+11.19+16.03
=216.3 kN
Computation of seismic force applied:
Type of building: RCMRF
Zone 4
Weightgroundfloor=168.79
Weightsecondfloor=265.42
Weightthirddfloor=265.42kN
Weightroofdeck=216.3 kN
∑W=915.93
∑h=9.20 m
Distance from seismic source A 50km
Table 208-1 (Importance factor, I) 1.00
Table 208-2 (Soil profile type) SD
Table 208-3 (Seismic zone factor, z) 0.40
Table 208-5 (Near source factor, Na) 1.00
Table 208-6 (Near source factor, Nv) 1.00
Table 208-11 (Numerical coefficient, R) 8.5
Table 208-7 (Seismic coefficient, Ca) 0.44Na
Table 208-8 (Seismic coefficient, Cv) 0.64Nv
Total seismic dead loads, W KN
Total height of the building, h 9.20m
T= 0.0731(∑h) ¾
= 0.0731(9.2) ¾
T= 0.3862sec
Ca= 0.44Na
= 0.44(1.00)
Ca= 0.44
Cv= 0.64Nv
= 0.64(1.00)
Cv= 0.64
CvIW 0.64(1)(915.93KN)
V= = = 178.57KN
RT 8.5(0.3862sec)
V not less than:
Vminimum= 0.11(CaIW)
= 0.11(0.44) (1) (915.93KN)
Vminimum= 44.33KN
For zone 4:
0.8z(Nv)Iw
Vminimum=
R
0.8(0.40)(1.0)(1)(915.93KN)
=
8.5
Vminimum = 34.48KN
V not exceed:
2.5CaIW
Vmaximum=
R
2.5(0.44)(1)(915.93KN)
=
8.5
Vmaximum = 118.53KN
Vminimum< V <Vmaximum
44.33KN < 178.57KN < 118.53KN
34.48KN < 178.57KN < 118.53KN
Therefore:
UseVmaximum = 118.53KN
When: T < 0.70s, Ft= 0
0.3862< 0.70s
Therefore: Ft= 0
(Vmaximum−Ft)Wxhx
Fx= ∑n
𝑖−1 Wihi
Level Wx, KN hx, m Wxhx, KN-m Fx,KN
Roof 216.3 9.2 1989.96 52.5919
3rd 265.42 6.2 1645.604 43.4911
2nd 265.42 3.2 849.344 22.447
Ground 168.79 0 0 0
∑= 4484.908 ∑= 118.53
VERTICAL IRREGULARITY:
WEIGHT(MASS) IRREGULARITY
1.5 WGROUNDFLOOR > WSECONDFLOOR
1.5(168.79kN) > 265.42kN
253.19kN> 265.42kN
253.19kN< 265.42kN
Therefore: There is no weight irregularity exis
LIVELOAD:
Descriptions ( Dormitory ) Uniform Load
LL ROOM 2.0KPa
LL CR/RESTROOM 2.1KPa
LL HALLWAY/CORRIDOR 3.8KPa
LL ROOF DECK 1.9KPa
LL KITCHEN 1.9KPa
(5.20KPa)(1.50m)
WLL1= = 2.60KN/m
3
(5.20KPa)(1.50m) 1.50m
WLL2= [3 – ( 4.5m ) 2] = 3.74KN/m
6
(1.9KPa)(2.30m)
WLL3= = 1.46KN/m
3
(1.9KPa)(2.30m) 2.30m
WLL4= [3 – (2.80m) 2] = 1.69KN/m
6
(2.1KPa)(1.50m)
WLL5= = 1.05KN/m
3
(2.1KPa)(1.50m) 1.50m
WLL6= [3 – (2.30m) 2] = 1.35KN/
6
(2.0KPa)(4.30m)
WLL7= = 2.87KN/m
3
(3.80KPa)(2.0m)
WLL8= = 2.53KN/m
3
(3.80KPa)(2.0m) 2.0m
WLL9== [3 – (4.30m) 2] = 3.53KN/m
6
(3.80KPa)(2.0m) 2.0m
WLL10= [3 – (2.30m) 2] = 2.84KN/m
6
(3.80KPa)(2.0m)
WLL11= = 2.53KN/m
3
(3.80KPa)(1.0m) 1.0m
WLL12= [3 – (3.0m) 2] = 1.83KN/m
6
(3.80KPa)(1.0m)
WLL13= = 1.27KN/m
3
(3.80KPa)(2.0m) 2.0m
WLL14= [3 – (2.8m) 2] =3.15KN/m
6
(3.80KPa)(2.0m)
WLL15= = 2.53KN/m
3
LIVELOAD PER FRAME:
FRAME A
FOR SECOND AND THIRD FLOOR
WEIGHT FOR SPAN 1=W LL8
=2.53Kn/m
WEIGHT FOR SPAN 2=W LL7
=2.87Kn/m
WEIGHT FOR SPAN 3=2.87Kn/m
WEIGHT FOR SPAN 4=W LL3
=1.46Kn/m
WEIGHT FOR SPAN 5=W LL1
=2.6Kn/m
FRAME B
FOR SECOND AND THIRD FLOOR
WEIGHT FOR SPAN 1=W LL8
=2.53Kn/m
WEIGHT FOR SPAN 2=W LL7
=2.87Kn/m
WEIGHT FOR SPAN 3=2.87Kn/m
WEIGHT FOR SPAN 4=W LL3
=1.35Kn/m
WEIGHT FOR SPAN 5=W LL1
=2.6Kn/m
FRAME C
FOR SECOND AND THIRD FLOOR
WEIGHT FOR SPAN 1=W LL
=2.53Kn/m
WEIGHT FOR SPAN 2=WLL7
=2.87Kn/m
WEIGHT FOR SPAN 3=2.87Kn/m
WEIGHT FOR SPAN 4=W LL3
=1.46Kn/m
WEIGHT FOR SPAN 5=W LL1
=2.6Kn/m
FRAME D
FOR SECOND AND THIRD FLOOR
WEIGHT FOR SPAN 2=W LL7
=2.87Kn/m
WEIGHT FOR SPAN 3= 2.87Kn/m
WEIGHT FOR SPAN 4=W LL6
=1.35Kn/m
WEIGHT FOR SPAN 5=W LL1
=2.6Kn/m
FRAME E
FOR SECOND AND THIRD FLOOR
WEIGHT FOR SPAN 1=W LL15
=2.53Kn/m
WEIGHT FOR SPAN 2=W LL7
=2.87Kn/m
WEIGHT FOR SPAN 3=2.87Kn/m
WEIGHT FOR SPAN 4=W LL3
=1.46Kn/m
WEIGHT FOR SPAN 5=W1
= 2.6Kn/m
******************************************************************************
******************************************************************************
**************************************************
**********
******************************************************************************
******************************************************************************
**************************************************
**********
******************************************************************************
******************************************************************************
**************************************************
**********