1 Appearance

OK Key
USB Interface Keypad Descriptions
Exiting Key ESC OK OK Key: Press to confirm operations. Hold the key for 2 s to enter the login interface.
Fingerprint Recognition Area
Network Interface Deleting Key: Press the key to delete the entered letter or number.
155 mm Direction Keys
Doorbell Button: Press the doorbell button and the doorbell rings.
1 2 3 Deleting Exiting Key: Press the key to exit the menu.
ABC DEF
Key
Display Screen Direction Keys: Press , , and to move the cursor.
4 5 6 Doorbell Numeric Keys/Letter Keys: Enter numbers or letters.
GHI JKL MNO
Button

140 mm
ESC OK Key 0 can also represent a space key except you are using the number input method.
Fingerprint Access Control Terminal 7
PQRS
8
TUV
9
WXYZ
0 Editing Key: Press the key to enter the number 0. Hold the key to shift among
1 2 3
numbers/lowercases, numbers/uppercases and symbols.
Keypad
ABC DEF

4
GHI
5
JKL
6
MNO
Wiring Terminal Numeric Keys/ Editing Key Notes:
Quick Start Guide 7
PQRS
8
TUV
9
WXYZ
0
Letter Keys 1. The pictures here are for reference only. Some models do not support card swiping
function. For details, refer to the actual products.
30 mm
Card Swiping Area Power Interface 2. If you enable the attendance status function, the OK key, the direction key, and the
UD12126B-B exiting key can be the shortcut key of the attendance status.

2 Installation
M4 Expansion Bolt

With Gang Box Without Gang Box


Expansion Sleeve
Device Mounting Gang Box
Plate

1
2
3
120 mm

4
Steps:
68.1 mm
Steps: 1. Stick a mounting template on the wall at a required height, and drill 4 holes according to the mounting
1. Install the gang box on the wall. template on the wall.
130.6 mm

36.5 mm
Note: Make sure the gang box screw holes match the mounting plate’s. The gang box here Note: The suggested distance between the device lower edge and the ground is 1.3 m.
2. Insert 4 supplied expansion sleeves of the setscrews (4_KA4×22-SUS) in the drilled holes.
83.65 mm

is for reference only. Select an appropriate gang box to install. The gang box is not supplied.
©2019 Hangzhou Hikvision Digital Technology Co., Ltd.
66.6 mm
The recommanded gang box dimension is 78 × 78 mm or 100 × 62 mm. 3. Fix and fasten the expansion bolts in the expansion sleeves respectively.
53.2 mm

It includes instructions on how to use the Product. The software embodied in the Note: Reserve 5.2 mm to 5.5 mm of expansion bolts outside the wall for hanging the device.
25.15 mm

2. Fix the mounting plate on the gang box with two supplied screws (SC-PM4X10-IMP).
Product is governed by the user license agreement covering that Product. 3. Route the device cable through the cable hole of the mounting plate and insert the cables 4. Align four holes of the device rear panel with the fixed screws and hang the device on the wall.
About this Manual Note: The additional force shall be equal to three times the weight of the equipment but not less than
This Manual is subject to domestic and international copyright protection. Hangzhou in the gang box.
Hikvision Digital Technology Co., Ltd. (“Hikvision”) reserves all rights to this manual. 4. Align the terminal with the mounting plate, and secure the terminal on the mounting plate 50 N. The equipment and its associated mounting means shall remain secure during the test. After the
This manual cannot be reproduced, changed, translated, or distributed, partially or with two supplied socket hexagon screws (SC-KM3X10_3-SUS). test, the equipment, including any associated mounting plate, shall not be damaged.
wholly, by any means, without the prior written permission of Hikvision.

3
Trademarks
and other Hikvision marks are the property of Hikvision and are
registered trademarks or the subject of applications for the same by Hikvision and/or

Activation
its affiliates. Other trademarks mentioned in this manual are the properties of their
respective owners. No right of license is given to use such trademarks without express
permission.
Legal Disclaimer
TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW, THE PRODUCT
DESCRIBED, WITH ITS HARDWARE, SOFTWARE AND FIRMWARE, IS PROVIDED “AS IS”,
WITH ALL FAULTS AND ERRORS, AND HIKVISION MAKES NO WARRANTIES, EXPRESS OR
Activating via Device Activating via SADP
IMPLIED, INCLUDING WITHOUT LIMITATION, MERCHANTABILITY, SATISFACTORY Power on and wire the network cable after installation. 1. Download SADP Software: Get the SADP software from the supplied disk or the official website. Install and run the software.
QUALITY, FITNESS FOR A PARTICULAR PURPOSE, AND NON-INFRINGEMENT OF THIRD You should activate the device before the first login. 2. Activate Device: Check the inactive device from the device list. Create a password in the right side of the interface and confirm the password.
PARTY. IN NO EVENT WILL HIKVISION, ITS DIRECTORS, OFFICERS, EMPLOYEES, OR 3. Edit Device IP Address: Check the device and manually edit the device IP address, Port No., Subnet Mask, Gateway, etc.
AGENTS BE LIABLE TO YOU FOR ANY SPECIAL, CONSEQUENTIAL, INCIDENTAL, OR After powering on, the interface will be displayed as follows.
INDIRECT DAMAGES, INCLUDING, AMONG OTHERS, DAMAGES FOR LOSS OF BUSINESS You can create the device password and confirm the password to activate.
PROFITS, BUSINESS INTERRUPTION, OR LOSS OF DATA OR DOCUMENTATION, IN
CONNECTION WITH THE USE OF THIS PRODUCT, EVEN IF HIKVISION HAS BEEN
ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. Device Activation
REGARDING TO THE PRODUCT WITH INTERNET ACCESS, THE USE OF PRODUCT SHALL
BE WHOLLY AT YOUR OWN RISKS. HIKVISION SHALL NOT TAKE ANY RESPONSIBILITIES Activation Password (8 to 16 Characters)
Activating via Client Software
FOR ABNORMAL OPERATION, PRIVACY LEAKAGE OR OTHER DAMAGES RESULTING
FROM CYBER ATTACK, HACKER ATTACK, VIRUS INSPECTION, OR OTHER INTERNET 1. Get the client software from the supplied disk or the official website. Install and run the client software.
SECURITY RISKS; HOWEVER, HIKVISION WILL PROVIDE TIMELY TECHNICAL SUPPORT IF 2. Click Device Management to enter the Device Management interface.
REQUIRED. 3. Select an inactive device from the Online Device list. Click Activate to pop up the Activation interface.
SURVEILLANCE LAWS VARY BY JURISDICTION. PLEASE CHECK ALL RELEVANT LAWS IN 4. Create a password and confirm the new password. Click OK to activate the device.
YOUR JURISDICTION BEFORE USING THIS PRODUCT IN ORDER TO ENSURE THAT YOUR OK Next. Input Method
5. Click Modify Netinfo to set the device IP address, mask address, gateway address, and port No.
USE CONFORMS THE APPLICABLE LAW. HIKVISION SHALL NOT BE LIABLE IN THE EVENT
THAT THIS PRODUCT IS USED WITH ILLEGITIMATE PURPOSES.
IN THE EVENT OF ANY CONFLICTS BETWEEN THIS MANUAL AND THE APPLICABLE LAW, [Number]
THE LATER PREVAILS.
Data Protection
During the use of device, personal data will be collected, stored and processed. To
protect data, the development of Hikvision devices incorporates privacy by design
principles. For example, for device with facial recognition features, biometrics data is STRONG PASSWORD RECOMMENDED–
stored in your device with encryption method; for fingerprint device, only fingerprint We highly recommend you create a strong password of your own choosing (using a minimum of 8 characters, including upper case letters, lower case letters,
template will be saved, which is impossible to reconstruct a fingerprint image. The default values of the terminal are as follows:
numbers, and special characters) in order to increase the security of your product. And we recommend you reset your password regularly, especially in the high
As data controller, you are advised to collect, store, process and transfer data in • The default IP address: 192.0.0.64
security system, resetting the password monthly or weekly can better protect your product.
accordance with the applicable data protection laws and regulations, including • The default port No.: 8000
without limitation, conducting security controls to safeguard personal data, such as, • The default user name: admin
implementing reasonable administrative and physical security controls, conduct
periodic reviews and assessments of the effectiveness of your security controls.
4 Device Wiring 5 Configuration
External Device Wiring Terminal Description User Management and Attendance Configuration are two main parts of the Access Control Terminal.

1 User Management
Line Terminal Manage User: In the New (New User) interface, enter the new user ID No., the user name, the card No. Register the fingerprint, set the password, select the department, set the user permission, select schedule template, set
No. Function Color Description
Group Name the authentication mode and set the duress card. Save the parameters to confirm adding.
Line A1 Power Input Red +12V 12V DC Power Supply
Group A A2 Black GND GND 2 Attendance Configuration
Line B1 Lock White/Purple NC Lock Wiring
Configure the shift via the device. You are able to schedule shift by department or by individual depending on the user property. The working flows are as follows:
Group B B2 White/Yellow COM Scheduling Shift by Department: Add User (See Step 1) - Edit Department - Configure Shift - Add Holiday - Configure Shift Schedule (by Department).
B3 White/Red NO Scheduling Shift by Individual: Add User (See Step 1) - Configure Shift - Add Holiday - Configure Shift Schedule (by Individual).
B4 Yellow/Green SENSOR Door Contact Signal Edit Department:
Input Select a department to edit in the department list. Select “Edit”and edit the department name. Save the parameters.
B5 Black GND GND
Configure Shift
B6 Yellow/Grey BUTTON Exit Door Wiring Normal Shift: In the Normal Shift page, configure the attendance rule, the normal shift attendance. Save the parameters to confirm setting.
Man-Hour Shift: In the Man-Hour Shift page, configure the man-hour shift parameters. Save the parameters to confirm setting.
Line C1 Door Bell Red BELL+
Group C Door Bell Wiring Add Holiday
C2 Yellow BELL- In the New (New Holiday) interface, enter the holiday No, the holiday name, the holiday start time and the holiday end time. Save the parameters.

Configure Shift Schedule


Schedule Shift by Department: Select a department to configure in the By Dept. (Schedule by Department) interface. Configure the shift, the start date, the end date and the holiday. Save the parameters.
Schedule Shift by Individual: Select New Individual Shift in the By Indiv. (Schedule by Individual) interface. Select a person to schedule in the New Individual Shift page. Configure the shift, the schedule start date and the
end date. Save the parameters.

Attendance Report
External Device Wiring Overview Plug the USB flash drive in the device. Enter Attendance - Report, select a table type, create a device ID, select start date and end date. Press OK to export.
The device will automatically check the USB flahs drive memory. If there is no enough space for exporting, a prompt will be popped up. You can configure the record over threshold prompt and record delete
pafarmeters in the System page.
Record over Threshold Pop up Prompt (%): If the attendance record memory reaches the configured value, the system pops up a prompt to remind you. If configure the threshold to 99%, the system will pop
up a prompt to remind you to delete the attendance data when the capacity reaches the threshold.
The available value: 1 to 99.
B1 Record Delete: When the function is enabled, the terminal will delete the first 3000 attendance records when the memory is full, in order to save the new attendance records. By default, the function is enabled. See
B2 Section 5.2 Attendance Record Delete Rule in User Manual of Fingerprint Time Attendance Terminal.
B3
B4 View License:
Black
B5 You can view the device License via the website: http://opensource.hikvision.com/Home/List?id=46
B6 Door Magnetic Contact
Gourp B
3 Other Settings
Manage Data: Enter System - Data page, and select Delete Event Only, Delete Attendance Data Only, Delete User Only, or Clear Permisison to manage the system data.
C1 Red
Factory Defualts: Enter System - Reset page, and select Factory Defaults. All device parameters will restore to the factory settings.
C2 Yellow
Default Settings: Enter System - Reset page, and select Default Settings. All parameters, excluding the communication parameters, and the remote user management paramters, will restore to factory settings.
Gourp C
Upgrage Device: Plug an USB flash drive to the device USB falsh drive interface. Tap System - Upgrade and tap OK to upgrade the device. The device will reboot automatically after upgrading is completed.
Notes:
1. The upgrading file should be in the root directoy in the USB flash drive.
Note: The external power supply and the access control terminal should use the same GND cable. 2. The upgrading file name should be digicap.dav.
3. Do not power off when device is upgrading.
Hik-Connect: You can operate the device via the Hik-Connect mobile client.

Regulatory Information This product and - if applicable - the supplied accessories too are
marked with "CE" and comply therefore with the applicable
Industry Canada ICES-003 Compliance
This device meets the CAN ICES-3 (B)/NMB-3(B) standards requirements.
Use only power supplies listed in the user instructions:

Model Manufacturer Standard


FCC Information harmonized European standards listed under the RE Directive This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two
Please take attention that changes or modification not expressly approved by the party responsible for compliance could 2014/53/EU, the EMC Directive 2014/30/EU, the RoHS Directive conditions: DSA-12PFT-12FUK 120100 Dee Van Enterprise Co., Ltd. BS
void the user’s authority to operate the equipment. 2011/65/EU. (1) this device may not cause interference, and
FCC compliance: This equipment has been tested and found to comply with the limits for a Class B digital device,
(2) this device must accept any interference, including interference that may cause undesired operation of the device.
pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful DSA-12PFT-12FAU 120100 Dee Van Enterprise Co., Ltd. AS
2006/66/EC (battery directive): This product contains a battery that Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radioexempts de licence.
interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if
cannot be disposed of as unsorted municipal waste in the European L'exploitation est autorisée aux deux conditions suivantes :
not installed and used in accordance with the instructions, may cause harmful interference to radio communications. DSA-12PFT-12FIN 120100 Dee Van Enterprise Co., Ltd. IS
Union. See the product documentation for specific battery (1) l'appareil ne doit pas produire de brouillage, et
However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause
information. The battery is marked with this symbol, which may (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible
harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the
include lettering to indicate cadmium (Cd), lead (Pb), or mercury (Hg). d'en compromettre le fonctionnement. DSA-12PFT-12FUS 120100 Dee Van Enterprise Co., Ltd. IEC
user is encouraged to try to correct the interference by one or more of the following measures:
For proper recycling, return the battery to your supplier or to a Under Industry Canada regulations, this radio transmitter may only operate using an antenna of a type and maximum
—Reorient or relocate the receiving antenna.
designated collection point. For more information see: (or lesser) gain approved for the transmitter by Industry Canada. To reduce potential radio interference to other users,
—Increase the separation between the equipment and receiver. DSA-12PFT-12 FBZ 120100 Dee Van Enterprise Co., Ltd. NBR
www.recyclethis.info the antenna type and its gain should be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more
—Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
than that necessary for successful communication.
—Consult the dealer or an experienced radio/TV technician for help.
Conformément à la réglementation d'Industrie Canada, le présent émetteur radio peut Scan the QR code to get the CAUTION
This equipment should be installed and operated with a minimum distance 20cm between the radiator and your body. 2012/19/EU (WEEE directive): Products marked with this symbol
FCC Conditions cannot be disposed of as unsorted municipal waste in the European
fonctionner avec une antenne d'un type et d'un gain maximal (ou inférieur) approuvé pour l'émetteur par Industrie user manual for detailed RISK OF EXPLOSION IF BATTERY IS
Canada. Dans le but de réduire les risques de brouillage radioélectrique à l'intention des autres utilisateurs, il faut information. REPLACED BY AN INCORRECT TYPE.
This device complies with part 15 of the FCC Rules. Operation is subject to the following two Union. For proper recycling, return this product to your local
choisir le type d'antenne et son gain de sorte que la puissance isotrope rayonnée équivalente (p.i.r.e.) ne dépasse pas
conditions: supplier upon the purchase of equivalent new equipment, or Note that mobile data DISPOSE OF USED BATTERIES
l'intensité nécessaire à l'établissement d'une communication satisfaisante.
1. This device may not cause harmful interference. dispose of it at designated collection points. For more information
This equipment should be installed and operated with a minimum distance 20cm between the radiator and your body. charges may apply if Wi-Fi is ACCORDING TO THE INSTRUCTIONS.
2. This device must accept any interference received, including interference that may cause see: www.recyclethis.info unavailable.
Cet équipement doit être installé et utilisé à une distance minimale de 20 cm entre le radiateur et votre corps.
undesired operation.
EU Conformity Statement

You might also like