AUTOMATION FOR

SMART MANUFACTURING

[Link]
SS2 series
General Vector Control Inverter

17
Product Range

kW 0.4 0.75 1.5 2.2 3.7 5.5


Model
(HP) (0.5) (1) (2) (3) (5) (7.5)
021 1 phase 220V
SS2 023 3 phase 220V
043 3 phase 440V

Main Features

* Built-in shuttle knob to adjust output frequency and set parameters easily
* Built-in RS485 communication interface
* Support MODBUS and Shihlin communication protocol
* Built-in proportion linkage control function to support multi inverters connection
* Maximum 599Hz frequency output
* Support DIN rail mount
* The resolution of frequency setting: digital 0.01Hz ; analog 1/1000
* The accuracy of output frequency: 0.01%
* Multi-function input/output terminals
* Support 2 analog setting types: 0-10V and 4-20mA

Model Identification

SS2 043 0.75K XY

Series Voltage level Capacity Version

043 : three phase 440V None : General model


SS2 series 023 : three phase 220V 0.75kW -xy : Customized or specialized or region
021 : single phase 220V difference

SS2

18
SS2 series General Vector Control Inverter

Product Features

General Flux Vector Control Technique PID Feedback Control Function


• General flux vector control technique.
• A 32-bit RISC CPU for high-speed computation.
• Starting torque, 150%3Hz.

Triangular Wave Function (traverse)


• This is suitable for operations that need traversing and winding
movements such as textile operations.

• Speed accuracy is within 1% (0%~100% loading changes).

f0 : Setting value of frequency


f1 : Generated amplitude for setting frequency (f0 X P.235 )
f2 : Compensation from acceleration to deceleration ( f1 X P.236 )
• Motor parameter auto-tuning function. f3 : Compensation from deceleration to acceleration ( f1 X P.237 )
• Stalling protection level reaches to 250%.

High Performance And Function Built-in Frequency And Parameter Setting Knob
• The maximum output frequency up to 599Hz.
• Soft-PWM functions for eliminating motor noises and
preventing the temperature of IGBT module too high.
• Built-in energy-saving control function, inverter will control
the output voltage automatically in order to reduce the
output power losses when inverter is running.
• Cooling fan operation method is selectable.

Built-in Proportion Linkage Function

19
Product Features

PWM Control Function Easy To Install Design


• The operating frequency can be controlled with the PWM • Din rail design for multiple inverters side by side installation.
signals output from PLC.
• The terminal M2 can be set as PWM signal input.

• Built-in standard RJ45 port for RS485 communication.


• Screwless terminal blocks designed

Programmed Operation Mode With Manual Operation

• The cooling fan is removable and easy to clean.

Equipped With Grid Power Frequency Switching


Mechanism
• It provides automatic switch between the grid power and
frequency conversion.
• If the motor is running at rated frequency, using grid power
frequency has a much better efficiency.

20
SS2 series General Vector Control Inverter

Electric Specifications

220V Series Single-Phase

Frame A B
Model SS2-021- □□□ K 0.4K 0.75K 1.5K 2.2K
HP 0.5 1 2 3
Applicable Motor Capacity
kW 0.4 0.75 1.5 2.2
Rated output capacity kVA (Note) 0.95 1.5 2.5 4.2
Output

Rated output current A (Note) 2.7 4.5 8 11


Overload current rating 150% 60 seconds; 200% 1 second (inverse time characteristics)
Maximum output voltage 3 Phase 200~240V AC
Rated power voltage Single phase 200~240V 50Hz/ 60Hz
supply
Power

Power voltage permissible fluctuation Single phase 170~264V 50Hz / 60Hz


Power frequency permissible fluctuation ±5%
Power source capacity kVA 1.5 2.5 3.5 6.4
Cooling Method Self-cooling Forced air cooling
Inverter weight (kg) 1.2 1.2 1.6 1.7

220V Series Three-Phase

Frame A B
Model SS2-023- □□□ K 0.4 0.75 1.5 2.2 3.7
HP 0.5 1 2 3 5
Applicable Motor Capacity
kW 0.4 0.75 1.5 2.2 3.7
Rated output capacity kVA (Note) 1.2 2 3.2 4.2 6.7
Output

Rated output current A (Note) 3 5 8 11 17.5


Overload current rating 150% 60 seconds; 200% 1 second (inverse time characteristics)
Maximum output voltage 3 Phase 200~240V AC
Rated power voltage 3 Phase 200~240V 50Hz/60Hz
supply
Power

Power voltage permissible fluctuation 3 Phase 170~264V 50Hz/60Hz


Power frequency permissible fluctuation ±5%
Power source capacity kVA 1.5 2.5 4.5 6.4 10
Cooling Method Self-cooling Forced air cooling
Inverter weight (kg) 1.1 1.2 1.2 1.6 1.7

440V Series Three-Phase

Frame A B
Model SS2-043- □□□ K 0.4 0.75 1.5 2.2 3.7 5.5
HP 0.5 1 2 3 5 7.5
Applicable Motor Capacity
kW 0.4 0.75 1.5 2.2 3.7 5.5
Rated output capacity kVA (Note) 1 2 3 4.6 6.9 9.2
Output

Rated output current A (Note) 1.5 2.6 4.2 6 9 12


Overload current rating 150% 60 Seconds; 200% 1 Second (inverse time characteristics)
Maximum output voltage Three-phase 380~480V
Rated power voltage 3 Phase 380~480V 50Hz / 60Hz
supply
Power

Power voltage permissible fluctuation 323~528V 50Hz/60Hz


Power frequency permissible fluctuation ±5%
Power source capacity kVA 1.5 2.5 4.5 6.9 10.4 13.8
Cooling Method Self-cooling Self-cooling Forced air cooling
Inverter weight (kg) 1.1 1.1 1.2 1.6 1.7 1.7

Note:
The test conditions of rated output current, rated output capacity and inverter power consumption are: the carrier frequency (P.72)
is at factory setting value; the inverter output voltage is at 220V/440V; the output frequency is at 60Hz, and the ambient temperature is 50℃ .

21
Common Specifications

Control Method SVPWM control, V/F control, general flux vector control.
Output Frequency Range 0.1~599Hz (The starting frequency setting range is betwee 0 and 60Hz).
If the frequency value is set below 100Hz, the resolution will be 0.01Hz.
Digital setting
If the frequency value is set above 100Hz, the resolution will be 0.1Hz.
Frequency Resolution
When setting the signal DC 0~5V, the resolution will be 1/500;
Analog setting
When setting the signal DC 0~10V or 4~20mA, the resolution will be 1/1000.
Output Frequency Digital setting Maximum target frequency±0.01%.
Accuracy Analog setting Maximum target frequency±0.5%.
Base voltage (P.19), base frequency (P.3) can be arbitrarily set.
Voltage / Frequency output Characteristics
Constant torque model and applicable load model can be selected (P.14).
Starting Torque 150% 3Hz, 200% 5Hz: when using the general flux vector control.
The torque boost setting range between 0 and 30% (P.0), auto boost, slip
Torque Boost
compensation.
The resolution (0.01s/0.1s) of acceleration/deceleration time (P.7, P.8) is switched
Acceleration / Deceleration Curve Characteristics by P.21. The setting range has 0~360s or 0~3600s for selection. And different
acceleration/deceleration curve model can be selected by P. 29.
The DC braking action frequency range between 0 and 120Hz (P.10); the DC
DC Braking braking time is 0~60 Seconds (P.11); and the DC braking voltage is 0~30% (P.12).
Linear braking and idling braking selection (P.71).
Stall current protection The stalling protection level can be set between 0 and 250% (P. 22).
Keypad setting, DC 0~5V signal setting, DC 0~10V signal setting, DC 4~20mA
Target Frequency Setting signal setting, Multi-speed stage levels setting, communication setting, pulse
frequency setting.
PID Control Please refer to P.170~P.183 in Chapter 5.
Motor starting (STF, STR), the second function (RT), '16-speed operation' (RL,
Multifunction Control Terminals RM, RH, REX), external thermal relay (OH), reset (RES), etc. (can be set by the user
(P.80~P.84, P.86)
Multi-function output Inverter running (RUN), output frequency detection (FU), Up to output
SO, SE P.40 frequency(SU), overload detection (OL), zero current detection (OMD),
terminals
alarm (ALARM), Section detection (PO1), Periodical detection (PO2), and
Multiple Output Terminals Pause detection (PO3), Inverter output (BP), Commercial power-supply
Multi-function output relay A, B, C P85
output (GP).
Analog output AM, 5 Multi-function DC (0~10V) Output: output frequency, output current (P.54).
Output frequency monitoring, output current monitoring, and output voltage
Running status monitoring
monitoring, alarm record
HELP mode Alarm history monitoring.
Keypad
Run indicator, frequency monitoring indicator, voltage monitoring indicator,
LED indicator (6) current monitoring indicator, mode switching indicator, and PU control
indicator.
Communication Function RS485 Build-in RS485 communication, RJ-45 connector.
Output short circuit protection, Over-current protection, (+/P)-(-/N)over-
voltage protection, under-voltage protection, motor over heat protection
Protection Mechanism / Alarm function
(P.9), IGBT module over-heat protection, communication abnormality
protection, etc.
Ambient temperature -10 ~ +50C (non-freezing), installation side by side -10~ +40℃ .
Ambient humidity Below 90%Rh (non-condensing)
Storage temperature -20 ~ +65℃
Surrounding environment Indoor, no corrosive gas, no flammable gas, no flammable dust
Environmental Condition
Altitude and vibration Altitude:below 1000 m, Vibration:below 5.9m/s2 (0.6G).
Enclosure Rating IP20
Pollution level 2
Class of protection Class 1
Certification

22
SS2 series General Vector Control Inverter

Wiring Diagram

Digital signal input

NOTE
1. For the usage of the external thermal relay, please refer to P.80~P.84, P.86 in Chapter 5 (OH) on the manual.
2. Make sure not to short circuit the PC and SD.
3. In the above figure, dotted line area, please refer to 3.5.7on the manual.
4. The SO terminal can select to FM or 10X function, please refer to P.64, P.74.
5. For single-phase series inverters, there is no T/L3 terminal, and the corresponding wiring(dotted line) doesn' t need to be connected.

23
Dimensions

Unit : mm
Frame A

Frame A

H H1 W W1 D
Model
(mm) (mm) (mm) (mm) (mm)
SS2-021-0.4K
SS2-021-0.75K
SS2-023-0.4K
SS2-023-0.75K
174 165 80 58 134
SS2-023-1.5K
SS2-043-0.4K
SS2-043-0.75K
SS2-043-1.5K

Frame B 43.5 2×R2.5


4.5

H2

DANGER:Risk of injure and electric shock


H1

Read the manual and follow the safety


H

instructions before use


Isolate from supply and wait 10 minutes
before removing this cover
Ensure proper earth connection

CAUTION:Risk of fire
D

Mount the inverter on a non combustible


surface

W1
W

Frame B

H H1 W W1 D
Model
(mm) (mm) (mm) (mm) (mm)
SS2-021-1.5K
SS2-021-2.2K
SS2-023-2.2K
SS2-023-3.7K 174 165 110.5 58 134
SS2-043-2.2K
SS2-043-3.7K
SS2-043-5.5K