DESIGN DETAILS
1. CLEAR COVER TO REINFORCEMENT FOR
FOOTINGS 40 MM , COLUMN 25 MM , BEAM 25
MM , SLAB 20 MM. CONSIDER GRADE OF
CONCRETE (RCC) - M25
2. REINFORCED STEEL TO BE USED IS IS1786
AND GRADE OF STEEL SHOULD BE FE-500 OR
G.L. HIGHER.
3. ALL THE PRECAUTIONS SUCH AS WATER
COLUMN CEMENT RATIO AND WORKABILITY OF THE
CONCRETE SHOULD BE ENSURED AT SITE.
REINFORCEMENT
A A 4. THE LAP LENGTH OF 50D SHOULD BE
REINFORCEMENT IN 'B' DIRECTION ENSURED.
IN 'L' DIRECTION 5. THE PLINTH BEAM SHOULD BE TESTED OR
PEDESTAL ONLY.
6. THE PLINTH BEAM SHOULD BE IN PERFECT
HORIZONTAL BEAM.
'D' 12" 12"
4" NOTE
4"
PLAN P.C.C. [Link]
THOUGH THE STRUCTURAL DESIGN WAS
PREPARED AS PER ROOM DIMENSION IT IS
IMPORTANT TO CHECK THE CENTER LINES WITH
TYPICAL FOOTING DETAIL OF COLUMN SECTION A-A RESPECT TO SIZES OF ROOMS BEFORE
PROCEEDING FOR EXCAVATION.
G.L. PROJECT : RESIDENTIAL PROJECT
COLUMN
B B CLIENT : MR. AADIL SHEIKH
'L' REINFORCEMENT TITLE : 4. FOUNDATION PLAN AND SECTION
IN 'L' DIRECTION
LOCATION : BALRAMPUR, UP
'D' 12"
'B'
PLAN
4" P.C.C. [Link]
TYPICAL FOOTING DETAIL OF SECTION B-B ER. NIKHIL THAWANI
CORNER WALL COLUMNS CIVIL ENGINEER
THAWANI DESIGNS & CONSTRUCTION
DESIGN THE FUTURE
BY ER. NIKHIL THAWANI TAHSIL ROAD CHAMPA
[Link] (CIVIL) +91-8889483367